返回 供应详情
西门子NCU573.2
西门子NCU573.2
来自:上海启水自动化科技有限公司
22人民币
发布时间:2012-10-29 关注次数:439
产品参数
产品参数
品牌 西门子
规格型号 进口原装
编号 齐全
计量单位
付款方式 面议
价格单位 人民币
商品详情

西门子NCU573.2
NCU  573.5/573.4/573.3/573.2/572.5/572.4/572.3/572.2/571.5/561.5/571.4/571.3/571.2

上海启水自动化科技有限公司(西门子核心分销商)

 联系人 :李 松( 销售经理 24小时服务热线 186 0165 7819

 电话( Tel ): 021-60641328    

工作( Q Q  1471187088 邮箱( Email )::1471187088@qq.com  

 地址( Add ):上海市松江区弘翔路58195

公司优势产品系列=西门子S7-200CN | S7-300PLC |  触摸屏 | 变频器 | 伺服电机 | 数控系统 | 总线电缆| 开关电源

 
SINUMERIK 840D/DE BOX FOR ELECTRONIC CONTROL DEVICE NCU BOX FOR INSTALLATION OF NCU 561.2/.3/.4/.5 NCU 571/571.2/.3/.4/.5 NCU 572/572.2/.3/.4/.5 NCU 573.2/.3/.4/.5 WITH POWER UNIT, BATTERY AND FAN

Technical specifications

Order No.

6FC5356-0BB15-0AA0

6FC5357-0BB15-0AA0

6FC5357-0BB25-0AA0

6FC5357-0BB35-0AA0

Product name

SINUMERIK 840D powerline NCU 561.5

SINUMERIK 840D powerline NCU 571.5

SINUMERIK 840D powerline NCU 572.5

SINUMERIK 840D powerline NCU 573.5

Processor

Celeron

 

 

Pentium III

SIMATIC S7 - integrated

PLC 317-2 DP

Input voltage

Via SIMODRIVE device bus

Degree of protection according to EN 60529 (IEC 60529)

IP20 (with NCU box)

Humidity rating in accordance with EN 60721-3-3

Class 3K5 condensation and icing excluded. Low air temperature 0 °C (32 °F).

Relative humidity

 

 

 

 

  • Storage

10 ... 95 %

 

 

 

  • Transport

10 ... 95 %

 

 

 

  • Operation

< 95% for 1h, annual average < 65%

Ambient temperature

 

 

 

 

  • Storage

-20 … +60 °C (-4 ... +140 °F)

 

 

 

  • Transport

-20 … +60 °C (-4 ... +140 °F)

 

 

 

  • Operation

0 … 55 °C (32 ... 131 °F)

 

 

 

Dimensions

 

 

 

 

  • Width

50 mm (1.97 in)

 

 

 

  • Height

316 mm (12.4 in)

 

 

 

  • Depth

207 mm (8.15 in)

 

 

 

Weight,approx.

0.72 kg (1.59 lb)

 

 

1.05 kg (2.32 lb)

Approvals

CE, cULus

 

 

 


Ordering data:
  

Release (only as spare part)
(product status: Cancellation/discontinuation):

6FC5357-0BB23-0AA0


(predecessor:
6FC5357-0BB22-0AE0)

SINUMERIK 840DE
NCU 572.3, 400 MHZ, 64 MB
WITHOUT SYSTEM SOFTWARE
MEMORY: NC 0.5MB, PLC 96KB
PROFIBUS-DP PREPARED
ACCORDING TO IEC 61508

6FC5357-0BB33-0AA0


(predecessor:
6FC5357-0BB33-0AE3)

SINUMERIK 840D/DE
NCU 573.3, 650 MHZ, 64 MB
WITHOUT SYSTEM SOFTWARE
MEMORY: NC 2.5MB, PLC 96KB
PROFIBUS-DP PREPARED
ACCORDING TO IEC 61508



NCU system software, compatibility:

  Hardware

NCU system software, compatibility subsequently tested

  NCU 572.3

 

6FC5357-0BB22-0AE0

   12-axis software:
  6FC520-_BY30-_AH_
  6FC520-_BX30-_AH_

  SW4.4 from V04.04.38
  SW5.3 from V05.03.08
  all SW6.x

6FC5357-0BB23-0AA0

  SW4.4 from V04.04.39
  SW5.3 from V05.03.42
  all SW6.x

  NCU 573.3

 

 

6FC5357-0BB33-0AE2

  12-axis software:  
  6FC520-_BY30-_AH_
  6FC520-_BX30-_AH_

  31-axis software:
  6FC520-_AY30-_AH_
  6FC520-_AX30-_AH_

   all SW4.x
  all SW5.x
  all SW6.x
  all SW7.x

6FC5357-0BB33-0AE3

  SW4.4 from V04.04.39
  SW5.3 from V05.03.18
  all SW6.x
  all SW7.x
  (see also !18682807!)

6FC5357-0BB33-0AA0

  SW4.4 from V04.04.39
  SW5.3 from V05.03.42
  all SW6.x
  SW7.2 from 07.02.07


Strategy in the spare parts business:

NCU 572.3
Predecessor  6FC5357-0BB22-0AE0  =>  successor  6FC5357-0BB23-0AA0

NCU 573.3
Predecessor  6FC5357-0BB33-0AE3  =>  successor  6FC5357-0BB33-0AA0

If there is no compatibility with the NCU software, the previous component should be used – or if this is no longer available, then an upgrade should be made to the specified update status or to the next higher update status in the meantime.

Depending on the inventory in the spare parts loop, spare part supply, supply as exchange and/or repair will be considered.


Strategy in the new part business:

NCU 572.3  =>  NCU 572.4 (or NCU 572.5)
Predecessor  6FC5357-0BB22-0AE0  =>  successor  6FC5357-0BB24-0AA0
                                                           or 6FC5357-0BB25-0AA0

NCU 573.3  =>  NCU 573.4 (or NCU 573.5)
Predecessor  6FC5357-0BB33-0AE3  =>  successor  6FC5357-0BB34-0AA0
                                                           or 6FC5357-0BB35-0AA0

The NCU *.3 components have been cancelled/discontinued effective 30.09.2004. The new replacement components in the new part business will be NCUs with integrated PLCs with a higher performance (NCU *.4 with integrated PLC 314C-2DP or NCU *.5 with integrated PLC 317-2DP):
 

PLC parameters

315-2DP
NCU *.3

314C-2DP
NCU *.4

317-2DP
NCU *.5

Processing time in ms/kI (1 kI = 1024 instructions, corresponds to approx. 3 kbytes)
- for bit commands (minimum)
- for commands (minimum)
Factor for cycle time for
user programs 1)



0.3
1.0

1



0.1
0.25

0.35



0.03
0.1

0.12

PLC user memory in kbytes,
basic version
max. expansion


96
288


96
480


128
768

No. of FBs, FCs

Each 256

Each 256

2048 2)

No. of DBs

399

399

20472)

No. of timers

128

256

512

No. of counters

64

256

512

I/O scope for cyclic process image

Each 128

    Each 128

Each 256

I/O scope for the complete logical I/O address space

Each 1024

Each 1024

Each 4096 3)

Max. number of Profibus slaves

63

32

125

 

Comments:

1)

The increase in performance refers to the computational performance available. Depending on the technological/process-related conditions, this increase in performance is included in the total result. A faster IPO clock cycle (as a result of faster processors) and lower PLC cycle times result, partially, in significantly improved technological/process-related results; e.g. shorter unit/clock cycle times, higher speeds for eccentric turning, higher feed rates for mould construction.

2)

The number specified is the upper address number that can be used; the maximum number of FBs, FCs and DBs is, as a total, 2048!
Reserved addresses should be taken into account; refer to the current documentation.

3)

4096 additional I/O addresses are available and can be seen in STEP 7; however these addresses are reserved for future applications. For compatibility reasons, these addresses may not be used. 
The diagnostic addresses (presently at the upper end 1023, 1022) must be appropriately marshaled in the PLC project; refer to the current documentation.

Brief instructions: (prerequisites: SIMATIC know-how; STEP 7)
When changing-over from an NCU with PLC315-2DP to an NCU with PLC 314C-2DP or PLC317-2DP, in the hardware configuration in the module catalog, the matching Rack0 should be selected under "SIMATIC 300\SINUMERIK\810D / 840D".
Further it should be checked as to whether a Profibus diagnostics block of A&D AS (FC125 or FB125) is used. These blocks must be brought up to the actual version (V4.9).