净重 (Kg) | 0.029 Kg |
产品尺寸 (W x L X H) | 未提供 |
包装尺寸 | 5.00 x 8.20 x 2.80 |
包装尺寸单位的测量 | CM |
数量单位 | 1 件 |
包装数量 | 1 |
其他产品信息 | |
EAN | 6940408100930 |
UPC | 040892696707 |
商品代码 | 85176200 |
LKZ_FDB/ CatalogID | ST72 |
产品组 | 4510 |
原产国 | 中国 |
Compliance with the substance restrictions according to RoHS directive | RoHS 合规开始日期: 2014.05.15 |
图10. EM AE04 组态 注:EM AE04 的设置以2个通道为一组设置
图11. EM AM06 组态 注: 西门子原装1200PLC通信板6ES7241-1CH30-1XB0
表9. EM AM06 输出通道报警
图12. EM AR02 模块组态
图13. EM AT04 模块组态 注:参考点设置仅在检测热电偶时有效 S7-200 到S7-200 SMART 基本程序移植以模拟量转换加上下限报警的程序为例:输入信号4~20mA;输出信号4~20mA 步骤1:STEP 7-MicroWIN SMART 打开S7-200 程序,如下图所示: 西门子原装1200PLC通信板6ES7241-1CH30-1XB0
图14. S7-200 SMART 编程界面 步骤2:添加硬件及组态,如下图所示:
图15. S7-200 SMART 组态界面 1,添加当前组态 2,修改通道属性 步骤3:修改程序 1,修改程序的硬件输入/输出地址; 2,模拟量量程替换: S7-200 :0~20mA:0~32000;4~20mA:6400~32000 S7-200 SMART:0~20mA:0~27648;4~20mA:5530~27648
图16. 修改硬件地址
图17. 修改程序段 步骤4:修改断电保持区域、修改安全等级及CPU上电运行模式 西门子原装1200PLC通信板6ES7241-1CH30-1XB0 |
与 SIRIUS 3RT2 接触器配套的功能模块
适用于直接起动器、可逆起动器和星-三角起动器的功能模块
提供了可方便地插到规格为 S00 和 S0 的新一代 3RT2 接触器中的功能模块,在组装直接起动器、可逆起动器和星-三角起动器时,可减少控制回路的接线。这样就可快速、方便、(被别是)可靠地实现这些规格的接触器组件。
用于直接起动(定时继电器)的功能模块可延时打开/闭合基本接触器,并具有较宽电压范围;可逆起动器组件集成有机械和电气联锁。若使用功能模块(而不是通过复杂接线)来实现性-三角组装,则不仅控制回路中的接线可节省 70%,而且所占的空间较小,因为已集成星-三角定时继电器和线圈保护电路。
用于接口至 PLC 的功能模块
上述具有起动器功能的功能模块也具有 AS-Interface 或 IO-Link 接口。除了分支内的接线减少之外,与上位 PLC 的接口也大大简化。至 PLC 的复杂控制电路接线几乎可以完全省略,而在 PLC 上,输入与输出模块仅需要很小的空间。
重新设计的 SIRIUS 组件无缝集成在 STEP 7 中,因此,可在 PLC 中集中获得数据,并可方便地将数据读出。这样就可在工厂范围内实现直至现场级部件的诊断。
通过 AS-i 或 IO-Link,可方便地传输电机起动器的运行数据,如就绪信号、ON/OFF 和组警告/故障等。由于始终可通过相同的输入/输出行规来寻址所有类型的起动器,各个分支的编程大大简化。
也可将“本地手动模式”、“顺时针/逆时针结束位置”、“辅助电压或电网电压缺失”等诊断消息直接传输到 PLC,或通过 IO-Link 来传输设备故障。
错误会立即被找到,并以普通文本的形式在一个中央位置或本地显示屏上提供,以便能快速得到纠正。
所有功能模块均可用于任何一种规格 (S00/S0),并且都可进行螺钉型端子连接和弹簧型端子连接。
SIPROCESS GA700 Rack/Wall-mounted Housing
Overview
Description
The new SIPROCESS GA700 series of gas analyzers makes it possible to combine up to two modules in one single housing: in either wall-mounted housing or in 19" rack housing with three different height units, depending on the individual requirements.
Overview of wall-mounted and rack housing options:
-
Both the wall-mounted and rack housing options with IP 65 protection class have ATEX and IEC Ex approval.
-
With Ex p protection, the pressurized wall-mounted unit can be operated together with an approved purging unit in Zone 1 for measuring both flammable and non-flammable gases.
-
With Ex nR protection, the restricted-breathing wallmounted unit can be operated in Zone 2 for measuring gases with concentrations always below the lower explosive limit (LEL).
-
With a suitable exterior casing, the 19" rack housing with Ex nA protection can be operated in Zone 2 for measuring both flammable and non-flammable gases.
Both housings can be used in environments with an ambient temperature of up to 50 °C (122 °F) and are equipped with the simple, easily understandable operating concept of the new SIPROCESS GA700 series.
Gas analysis with the SIPROCESS GA700: highly accessible servicing and a uniform operating concept.
Gas analysis has never been easier!
-