205.00x100.00x40.50 (mm) 8.07x3.94x1.59 (inch) |
| |
VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 60~50 HZ INPUT CURRENT: 6.0 A ( RMS ) FOR 110VAC 3.0 A ( RMS ) FOR 220VAC INRUSH CURRENT: 60.0A MAX. FOR 110 VAC 80.0A MAX. FOR 220 VAC |
| | | |
|
Output Voltage |
Output Current Min. |
Output Current Max. |
Output Current Peak |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
5V |
3 |
25.00 |
|
± 5% |
± 1% |
50mV | | |
|
-5V |
0.05 |
0.5 |
|
±10% |
± 1% |
120mV | | |
|
-12V |
0.05 |
1 |
|
±10% |
± 1% |
150mV | | |
|
+5VSB |
0.1 |
1.5 |
|
± 5% |
± 1% |
50mV | | |
|
|
REMARKS: 1. THE OUTPUT POWER OF 5V & 3.3V NOT EXCEED 138 WATTS 2. THE OUTPUT POWER OF 5V, 3.3V AND 12V NOT EXCEED 278 W 3. TOTAL OUTPUT POWER NOT EXCEED 300 WATTS |
*Active PFC (full range), MEET IEC-1000-3-2 CLASS D *12V Max. Current : 16A *TEMPERATURE RANGE: OPERATING 0℃ ~ 40℃ * HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95% * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS *EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B *OVER POWER PROTECTION *OVER VOLTAGE PROTECTION *OVER CURRENT PROTECTOIN *SHORT CIRCUIT PROTECTOIN *SAFETY: UL, CSA, TUV, CCC, GOST *Cooling: Dual 40 mm DC Fans *3.3V /5V Remote sensing *DC wires output from left side ( optional ) *Serial ATA optional
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS | | | | |