0/100
SOUTHERN AVIONICS 供应SAC4343
来自:厦门纪扬科技有限公司
1人民币
发布时间:2017-11-8
关注次数:126
产品参数
商品详情
Data subject to change without notice.
Temporary Power
Metered
Top Feed, 40 – 90 Amps, 120/240V
Fig. A
M036C010, R036C010
6-20R, 5-20R2GFCI
Fig. G
M055C033, R055C033
BR54U, 5-20R2GFCI
Fig. H
M055G, R055G
BR54U, (2) 5-20R2
Fig. I
M055GP6033
BR54U, 5-20R2
Fig. J
M076C010, R076C010
BR54U, (2) 5-20R2GFCI
Fig. K
M076C033, R076C033
BR54U, (2) 5-20R2GFCI
Fig. B
M036C033
6-20R, 5-20R2GFCI
Fig. C
M036G, R036G
6-20R, 5-20R2
Fig. D
M051C010
10-50R, 5-20R2GFCI
Fig. E
M051G
10-50R, 5-20R2
Fig. F
M055C010, R055C010
BR54U, 5-20R2GFCI
20 20
GFI
50
GFI
20
GFI
20 20
GFI
GFI
50 20
GFI
20 20
GFI
50
GFI
20
GFI
POST
50 20
GFI
50 20
GFI
50
GFI
20 20
GFI GFI
50 20
GFI GFI
SPACE
20
50 20
GFI
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ringtype Ringless
A M036C010 R036C010 6-20R,
5-20R2GFCI
CB220,
CB120 40 AA 9 x 30
Y
LC33N1 25
1
B M036C033 — 6-20R, Y2
5-20R2GFCI
GFI230,
CB120 40 AA 9 x 30 LC33N1 23
C M036G R036G 6-20R,
5-20R2
CB220,
GF1120 40 AA 9 x 30 LC33N1 25
D M051C010 — 10-50R,
5-20R2GFCI
CB250,
CB120 70 AA 9 x 30 LC33N1 25
N
E M051G — 10-50R,
5-20R2
CB250,
GF1120 70 AA 9 x 30 LC33N1 25
F M055C010 R055C010 BR54U,
5-20R2GFCI
CB250,
CB120 70 K 9 x 30 LC33N1 25
Y2
G M055C033 R055C033 BR54U,
5-20R2GFCI
GFI250,
CB120 70 K 9 x 30 LC33N1 23
H M055G R055G BR54U,
5-20R2
CB250,
GFI120 70 AA 9 x 30 LC33N1 25
I M055GP60331 — BR54U,
5-20R2
GFI120,
GFI250 70 A2 9 PT LC33N1 51
J M076C010 R076C010 BR54U,
(2) 5-20RGFCI
CB250, (2) CB120,
Space CB120 90 AA 9 x 30 LC55N1 25
K M076C033 R076C033 BR54U,
(2) 5-20RGFCI
GFI250, (2) CB120,
Space CB120 90 AA 9 x 30 LC55N1 25
1 Earth Burial Post. See page 90 for post mounted dimensions.
2 cULus approved.
* Wire Range Table on page 49.
Midwest Electric Products
Temporary Power
44
Data subject to change without notice.
Temporary Power
Metered
Top Feed, 100 Amps, 120/240V
Fig. B
M011G, R011G
(2) 5-20R2
Fig. A
M011C010, R011C010
(2) 5-20R2GFCI
Fig. C
M038C010, R038C010
6-20R, (2) 5-20R2GFCI
Fig. E
M038CB1010
6-20R, (2) 5-20R2GFCI
Fig. D
M038C033, R038C033
6-20R, (2) 5-20R2GFCI
Fig. F
M038CB1033
6-20R, (2) 5-20R2GFCI
Fig. G
R038CP4010
6-20R, (2) 5-20R2GFCI
GFI GFI
SPACE
20 20
SPACE
20
GFI
20
GFI
20
GFI
20
GFI GFI
SPACE
20 20
GFI
20
GFI GFI
SPACE
20
BARRIER
20 20
GFI GFI
SPACE
20 20 20
GFI GFI
SPACE
20
BARRIER
20 20
GFI GFI
SPACE
20
POST
Fig. H
R038CP4033
6-20R, (2) 5-20R2GFCI
20
GFI
20
GFI GFI
SPACE
20
POST
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ringtype Ringless
A M011C010 R011C010 (2) 5-20R2GFCI (2) CB120,
Space CB120 100 AA 9 x 30
Y
LC33N1 21 1
Y2
B M011G R011G (2) 5-20R2 (2) GFI120,
Space CB120 100 AA 9 x 30 LC33N1 21 1
C M038C010 R038C010 6-20R,
(2) 5-20R2GFCI
CB220, (2) CB120,
Space CB120 100 AA 9 x 30 LC55N1 25 1
D M038C033 R038C033 6-20R,
(2) 5-20R2GFCI
GFI220, (2) CB120,
Space CB120 100 AA 9 x 30 LC55N1 24 1
E M038CB1010 — 6-20R,
(2) 5-20R2GFCI
CB220, (2) CB120,
Space CB120 100 AA 14 x 26 LC55N1 33 1
Y
F M038CB1033 — 6-20R,
(2) 5-20R2GFCI
GFI220, (2) CB120,
Space CB120 100 AA 14 x 26 LC55N1 33 1
G — R038CP40101 6-20R,
(2) 5-20R2GFCI
CB220, (2) CB120,
Space CB120 100 A2 9 PT LC55N1 45 1
H — R038CP40331 Y2 6-20R,
(2) 5-20R2GFCI
GFI220, (2) CB120,
Space CB120 100 A2 9 PT LC55N1 45 1
I M038G R038G 6-20R,
(2) 5-20R
CB220, (2) GFI120,
Space CB120 100 AA 9 x 30 LC55N1 25 4
J M038GB1 — 6-20R,
(2) 5-20R
CB220, (2) GFI120,
Space CB120 100 AA 14 x 26 LC55N1 35 1
Y
K M038GB1033 — 6-20R,
(2) 5-20R2
GFI220, (2) GFI120,
Space CB120 100 AA 14 x 26 LC55N1 35 1
1 Pad Mount Post. See page 90 for post mounted dimensions.
2 cULus approved.
* Wire Range Table on page 49.
Fig. J
M038GB1
6-20R, (2)5-20R
Fig. K
M038GB1033
6-20R, (2)5-20R
20 20
GFI
SPACE
20
GFI
BARRIER
20
GFI
20
GFI
SPACE
20
GFI
BARRIER
Fig. I
M038G, R038G
6-20R, (2)5-20R
SPACE
20
GFI
20
GFI
20
Midwest Electric Products
Temporary Power
45
Data subject to change without notice.
Temporary Power
Metered
Bottom Feed, 40 – 100 Amps, 120/240V
Fig. A
M036C010U
6-20R, 5-20R2GFCI
Fig. G
M038C010U, R038C010U
6-20R, (2) 5-20R2GFCI
Fig. B
M055C010U, R055C010U
BR54U, 5-20R2GFCI
Fig. H
M038C033U, R038C033U
6-20R, (2) 5-20R2GFCI
Fig. C
M055C033U, R055C033U
BR54U, 5-20R2GFCI
Fig. I
R038GU
6-20R, (2) 5-20R2
Fig. D
M076C010U, R076C010U
BR54U, (2) 5-20R2GFCI
Fig. J
M041C010U
R32U, 5-20R2GFCI
Fig. E
M011C010U, R011C010U
(2) 5-20R2GFCI
Fig. K
M075C010U, R075C010U
BR54U, R32U, 5-20R2GFCI
Fig. F
R031C010U
R32U, (2) 5-20R2GFCI
Fig. L
M355C010U
BR54U, 5-20R2GFCI
20 20
GFI
20 20
GFI GFI
SPACE
20
50 20
GFI
20
GFI
20
GFI GFI
SPACE
20
50 20
GFI
GFI
20 20
GFI
20
GFI
SPACE
30 20
GFI
SPACE
50 30 20
GFI
SPACE
50 20
GFI
SPACE
SPACE
50 20
GFI GFI
SPACE
20
GFI GFI
SPACE
20 20 30 20 20
GFI GFI
SPACE
SPACE
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ringtype Ringless
A M036C010U — 6-20R,
5-20R2GFCI
CB220,
CB120 40 X 9 x 30U N LC33N1 25
1 Y1
B M055C010U R055C010U BR54U,
5-20R2GFCI
CB250,
CB120 70 H 9 x 30U N LC33N1 25
C M055C033U R055C033U BR54U,
5-20R2GFCI
GFI250,
CB120 70 H 9 x 30U Y LC33N1 23
D M076C010U R076C010U BR54U,
(2) 5-20R2GFCI
CB250, (2) CB120,
Space CB120 90 X 9 x 30U N LC55N1 25
E M011C010U R011C010U (2) 5-20R2GFCI (2) CB120,
Space CB120 100 X 9 x 30U N LC33N1 21
F — R031C010U R32U,
(2) 5-20R2GFCI
CB130,
(2) CB120 100 AA 9 x 30U Y LC55N1 25
G M038C010U R038C010U 6-20R,
(2) 5-20R2GFCI
CB220, (2) CB120,
Space CB120 100 X 9 x 30U N LC55N1 25
H M038C033U R038C033U 6-20R,
(2) 5-20R2GFCI
GF1220, (2) CB120,
Space CB120 100 X 9 x 30U Y LC55N1 26
I — R038GU 6-20R,
(2) 5-20R2
CB220,
(2) GFI120 100 X 9 x 30U N LC55N1 25
J M041C010U — R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100 AA 9 x 30U Y LC33N1 25
K M075C010U R075C010U BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, (1) Space 100 AA 9 x 30U Y LC55N1 25
L M355C010U — BR54U,
5-20R2GFCI
CB250, CB120,
(2) Space CB120 100 AA 9 x 30U Y LC55N1 25
1 cULus approved.
* Wire Range Table on page 49.
Midwest Electric Products
Temporary Power
46
Data subject to change without notice.
Temporary Power
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches) Knockout
Meter Socket Height (A) Width (B) Depth (C) Figure2
M011C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M011C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M011G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M036C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M036C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M036C033 MSM100930 9 X 30 B 30 9-3/4 5-3/16 2
M036G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M038C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M038C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M038C033 MSM100930 9 X 30 B 30 9-3/4 5-3/16 2
M038C033U MSM100EZ 9 X 30U C 30 9-3/4 5-3/16 3
M038CB1010 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4
M038CB1033 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4
M038G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M038GB1 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4
M038GB1033 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4
M041C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
M051C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M051G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M055C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M055C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M055C033 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M055C033U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M055G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M055GP6033 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M075C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
M076C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M076C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M076C033 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M355C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
R011C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R011C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R011G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R031C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
R036C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R036C010U MSR100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R036G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R038C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R038C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R038C033 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R038C033U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R038CP4010 MSR100EZ 9 PT B 30 9-3/4 5-3/16 2
R038CP4033 MSR100EZ 9 PT B 30 9-3/4 5-3/16 2
R038G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R038GU MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R055C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R055C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R055C033 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R055C033U MSM100EZ 9 X 30U C 30 9-3/4 5-3/16 3
R055G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R075C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
R076C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R076C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R076C033 MSR100930 9 X 30 B 30 9-3/4 5-3/16 2
1 Enclosure Styles on page 47.
2 Knockout Figures on page 48.
Midwest Electric Products
Temporary Power
47
Data subject to change without notice.
Temporary Power
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches) Knockout
Meter Socket Height (A) Width (B) Depth (C) Figure2
U011C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U011G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U011GTL — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U030 — 5 x 7 A 7-1/8 5-3/4 5-3/16 1
U036C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U036C033 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U036G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U038C010 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U038C033 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U038CTL010 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U038CTL033 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U038G — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U039G6 — 9 x 21 D 21 9-3/4 5-3/16 5
U051C — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U051C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U051C033 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U051G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U054C — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U055C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U055C033 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U055G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U072C — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U073G — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U076C010 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U076C033 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U076G — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
1 Enclosure Styles on page 47.
2 Knockout Figures on page 48.
Cabinet Dimensions
Fig. A
Fig. D
Fig. B Fig. C
B C
A
B C
A
B C
A
A
B C
Midwest Electric Products
Temporary Power
48
Data subject to change without notice.
Temporary Power
Knockout Congurations
Fig. 1
Fig. 4
Fig. 2 Fig. 3
Fig. 5
G G G G
G N G
P P P
W W
A
G G G
N N
G
G G
G W B
G
G
G
G D
B B
G
* Knockouts shown for size not for exact positions.
Knockout Key
A = 1/2"
B = 1", 1-1/4", 1-1/2"
D = 3/4", 1", 1-1/4"
G = 1/2", 3/4", 1"
N = 1/2", 3/4", 1", 1-1/4", 1-1/2"
P = 1/2", 3/4", 1", 1-1/4", 1-1/2", 2", 2-1/2"
W = 1/2", 3/4", 1", 1-1/4", 2"
Midwest Electric Products
Temporary Power
49
Data subject to change without notice.
Temporary Power
Wire Range Tables
AA
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load 14-10 14-10 — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
A2
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load 14-10 14-10 — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors
Suitable for Loop Feed 2-250 kcmil 2-250 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
C
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 1-300 — 1-300
Ground - Large Hole 12-8 12-1/0 12-10 10-1/0
Ground - Small Hole 14-8 14-4 12-10 10-1/0
Neutral - Large Hole 14-1/0 14-1/0 14-1/0 14-1/0
Neutral - Small Hole 14-6 14-6 14-6 14-6
G
Connector
Copper
Solid Strand
Line 12-8 12-4
Load — —
Neutral 12-8 12-4
Equipment Ground 12-8 12-2
H
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load 14-10 14-10 — —
Neutral — 6-350 — 6-350
Neutral — 1-300 — 1-300
Equipment Ground 12-8 12-2 12-8 12-2
K
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load 14-10 14-10 — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
O
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
U
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load 14-10 14-10 — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
V
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load — — — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
X
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load 14-10 14-10 — —
Neutral — 6-350 — 6-350
Neutral — 1-300 — 1-300
Equipment Ground 12-8 12-2 12-8 12-2
Data subject to change without notice.
Midwest Electric Products
50
Power Outlets
Midwest Electric Products
Power Outlets
51
Data subject to change without notice.
Power Outlets
Application Information
Portable equipment requiring electricity continues to
increase steadily in both number and variety. This creates
the need for conveniently located receptacles to provide
power for cord connected equipment. Midwest Electric
Power Outlets provide one or more receptacles, with or
without overcurrent protection, in a single enclosure,
eliminating the need for several separately mounted
components while providing maximum protection
against weather and normal field use. Additionally, many
models also include disconnecting, metering, and/or
pedestal mounting functions in a single NEMA 3R
enclosure/assembly.
Features and Benets
? NEMA 3R weatherproof construction
? G90 galvanized steel construction for superior
corrosion resistance
? Durable polyester powder coat finish resists chipping
and fading
? All in one construction for factory assured terminations
? Rolled edge door for cord protection
? Cover design allows cords to exist while maintaining
the NEMA 3R integrity
? Wide assortments of concentric knockouts offer flexibility
in the installation
? All GFCI duplexes are listed as weather resistant and
tamper resistant as required by NEC in Article 406.8
and 406.11
? Padlockable door to help prevent unauthorized access
? Dead front construction prevents accidental contact
with live parts
? All components factory wired and assembled
U013
U014C010
Midwest Electric Products
Power Outlets
52
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 20 – 30 Amps, 120V
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U010 5-20R2 — 20 E 5 x 7
Y
— 4.5
4 Y1
B U010F 5-20R2 FH2 20 E 5 x 7 — 4.5
C U010H 5-20R2 FH2,
SP Switch 20 E 5 x 7 — 5
D U010010 5-20R2GFCI — 20 E 5 x 7 — 4.5
E U011 (2) 5-20R2 — 20 E 5 x 7 — 4.5
F U011010 (2) 5-20R2GFCI — 20 E 5 x 7 — 4.5
F U012010 (2) 5-20R2GFCI — 20 E 5 x 7 N — 4.5
G U013 R32U — 30 F 5 x 7
Y
— 4.5
H U013C R32U CB130 30 A 6 x 9 LC31N3 7
I U013F R32U FH3 30 F 5 x 7 — 4.5
1 cULus approved.
* Wire Range Table on page 62-63.
Fig. A
U010
5-20R2
Fig. F
U011010, U012010
(2) 5-20R2GFCI
Fig. B
U010F
5-20R2
Fig. D
U010010
5-20R2GFCI
Fig. H
U013C
R32U
Fig. C
U010H
5-20R2
Fig. G
U013
R32U
Fig. E
U011
(2) 5-20R2
Fig. I
U013F
R32U
GFI
GFI GFI 30
Midwest Electric Products
Power Outlets
53
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 20 – 50 Amps, 120/240V
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U010C 5-20R2 CB120 20 B 6 x 9
Y
LC31N3 7
4
Y2
B U011F (2) 5-20R2 (2) FH2 20 E 6 x 9 — 9
C U023 7310 — 20 F 5 x 7 — 4.5 N
D U041 R32U,
5-20R2 — 30 E 6 x 9 — 6
E U041F R32U, Y2
5-20R2 FH3, FH2 30 E 6 x 9 — 7
F U041010 R32U,
5-20R2GFCI — 30 J 6 x 9 — 9
G U050 10-50R — 50 G 5 x 7 — 4.5
N
H U051F 10-50R,
5-20R2 FH2 50 K 6 x 14 FR66 10
I U054 BR54U — 50 G 5 x 7 — 5
Y2
J U054F BR54U — 50 O 6 x 14 FR67 10
K U055010 BR54U,
5-20R2GFCI — 50 J 6 x 9 — 9
L U055F BR54U,
5-20R2 — 50 L 6 x 14 FR66, FH2 9
M U061C1 (2) R32U (2) CB130,
Space CB120 50 O 6 x 14 LC33N7 10
N U550F BR54U,
5-20R2 FH2 50 M 6 x 14 — 6
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
* Wire Range Table on page 62-63.
Surface, 50 Amps, 240V
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
O U501 6-50R — 50 P 5 x 7 Y — 5 4 Y
* Wire Range Table on page 63.
Fig. A
U010C
5-20R2
Fig. I
U054
BR54U
Fig. B
U011F
(2) 5-20R2
Fig. J
U054F
BR54U
Fig. D
U041
R32U, 5-20R2
Fig. F
U041010
R32U, 5-20R2GFCI
Fig. L
U055F
BR54U, 5-20R2
Fig. N
U550F
BR54U, 5-20R2
Fig. C
U023
7310
Fig. K
U055010
BR54U, 5-20R2GFCI
Fig. E
U041F
R32U, 5-20R2
Fig. G
U050
10-50R
Fig. H
U051F
10-50R, 5-20R2
Fig. M
U061C
(2) R32U
Fig. O
U501
6-50R
20
GFI
30 30
SPACE
GFI
Midwest Electric Products
Power Outlets
54
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 60 – 100 Amps, 120/240V
Fig. A
U546
14-60R
Fig. F
U511G
6-50R, 5-20R2
Fig. G
U666C010
10-30R, (2) 5-20R2GFCI
Fig. H
U058C
BR54U, BR32U
Fig. I
U070C
10-50R, 7310, 5-20R2
Fig. B
U041C
R32U, 5-20R2
Fig. C
U050C
10-50R
Fig. D
U361G
(2) 5-20R2
Fig. E
U511C
6-50R, 5-20R2
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U546 14-60R — 60 G 6 x 9
Y
— 5
4
N
B U041C R32U,
5-20R2
CB130, CB120,
Space CB120 70 K 6 x 14 LC33N7 10 Y2
C U050C 10-50R CB250,
Space CB120 70 O 6 x 14 LC33N7 10 N
D U361G (2) 5-20R2 GFI120 70 K 6 x 14 LC33N7 9 Y2
E U511C 6-50R,
5-20R2
CB250,
CB120 70 K 6 x 14 LC33N7 10 Y2
F U511G 6-50R,
5-20R2
CB250,
GFI120 70 K 6 x 14 LC33N7 10 Y2
G U666C010 10-30R,
(2) 5-20R2GFCI
CB230, (2) CB120,
Space CB120 70 U 9 x 17 LC55N1 16
1
N
H U058C1 BR54U,
BR32U
CB250,
CB130 80 V 9 x 17 LC33N1 15 Y2
I U070C 10-50R, 7310,
5-20R2
CB250, CB220,
CB120 90 U 9 x 17 LC55N1 16 N
J U002C (2) 10-50R,
5-20R2
(2) CB250,
CB120 100 U 14 x 21 LC55N1 31 N
K U132CTL R32U CB130,
Space (2) CB120 100 V 9 x 17 LC33N1T 11 Y2
L U014C0103 (4) 5-20R2GFCI (4) CB120,
Space CB120 100 U 9 x 17 LC55N1 28 Y2
M U061CTL (2) R32U (2) CB130,
Space CB120 100 O 9 x 17 LC33N1T 14 Y2
N U075C BR54U, R32U,
5-20R2
CB250, CB130,
CB120, Space CB120 100 U 9 x 17 LC55N1 16 Y2
O U354C BR54U CB250,
Space (3) CB120 100 V 9 x 17 LC55N1 16 Y2
P U614C1 (2) R32U,
(2) BR32U
(4) CB130,
Space CB120 100 V 14 x 21 LC55N1 30 Y2
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
3 Earth Burial Model U014CP6010.
* Wire Range Table on page 63.
50 20
GFI
30
SPACE
20 20
SPACE
30 20
GFI GFI
SPACE
50 20 50 30
GFI
SPACE
SPACE
50 20 20
GFI
50 20
Fig. J
U002C
(2) 10-50R, 5-20R2
Fig. K
U132CTL
R32U
Fig. M
U061CTL
(2) R32U
Fig. O
U354C
BR54U
Fig. L
U014C010
(4) 5-20R2GFCI
Fig. N
U075C
BR54U, R32U, 5-20R2
Fig. P
U614C
(2) R32U, (2) BR32U
50 50 20 SPACE
30
SPACE
20 20 20 20
GFI GFI GFI GFI
SPACE
30 30
SPACE
30 20
SPACE
50
SPACE
SPACE
SPACE
50 30 30 30 30
SPACE
Midwest Electric Products
Power Outlets
55
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 120 – 200 Amps, 120/240V
Metered
Surface, 80 – 100 Amps, 120V/240V
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U004CTL010 (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 U 9 x 17
Y
LC55N1T 17
1 Y1
B U004F (2) BR54U,
5-20R2 FH2 120 U 14 x 21 FR64X2 30
C U870G6 L6-30R,
(2) L5-20R
GFI230, (2) GFI120,
Space CB120 125 Q 9 x 21 LC1212PC 16
D U239G L6-30R,
(2) L5-20R
GFI230,
(2) GFI120 200 N 14 x 21 LC1212PC 30
1 cULus approved.
* Wire Range Table on page 63.
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
E R058C1 BR54U,
R32U
CB250,
CB130 80 AD 9 x 30
Y
LC33N1
25 1 Y2
F M354C BR54U CB250,
SPACE (3) CB120 100 AD 9 x 30 LC55N1
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
* Wire Range Table on page 62.
Fig. B
U004F
(2) BR54U, 5-20R2
Fig. C
U870G6
L6-30R, (2) L5-20R
Fig. E
R058C
BR54U, R32U
Fig. D
U239G
L6-30R, (2) L5-20R
Fig. A
U004CTL010
(2) BR54U, 5-20R2GFCI
Fig. F
M354C
BR54U
SPACE
30
GFI
20
GFI
20
GFI
SPACE
SPACE
SPACE
SPACE SPACE
SPACE SPACE
SPACE
20
GFI
20
GFI
30
GFI
50 20 50
GFI
50 30 50
SPACE
SPACE
SPACE
Midwest Electric Products
Power Outlets
56
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 20 Amps, 120V
Surface, 20 Amps, 240V
Fig. Model Number Receptacles Number of GFI Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Enclosure
Color
Unit
Wt.
Std
Pkg.
UL
A U010010GRP1 5-20R2GFCI 1 20 E
5 x 7 N
Camo
Green 4
1 Y2
B U010S010 5-20R2GFCI,
Switch 1 20 R Gray 4
B U010S010GRP1 5-20R2GFCI,
Switch 1 20 R Camo
Green 3
C U012010GRP1 (2) 5-20R2GFCI 2 20 J Camo
Green 3
Fig. Model Number Receptacles Number of GFI Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Enclosure
Color
Unit
Wt.
Std
Pkg.
UL
D U025S L6-20R Twist Lock,
Switch — 20 R 5 x 7 N Gray 4 4 Y2
1 Available in standard gray paint. U010010, U010S010, U012010 see page 138.
2 cULus approved.
* Wire Range Table on page 62-63.
Fig. B
U010S010, U010S010GRP
5-20R2GFCI, Switch
Fig. C
U012010GRP
(2) 5-20R2GFCI
Fig. D
U025S
L6-20R Twist Lock,
Switch
Fig. A
U010010GRP
5-20R2GFCI
GFI GFI GFI GFI
Midwest Electric Products
Power Outlets
57
Data subject to change without notice.
Power Outlets
Unmetered
Pedestal, 70 – 80 Amps, 120/240V
Fig. A
U061CP6
(2) R32U
Fig. D
U061CB6
(2) R32U
Fig. E
U132CB6
R32U
Fig. F
U058CB6
BR54U, R32U
Fig. B
U132CP6
R32U
Fig. C
U058CP6
BR54U, R32U
30
SPACE
30
POST
30
SPACE
30 30
SPACE
30
POST
SPACE
30
SPACE
POST
SPACE
30
SPACE
30
POST
50 50 30
SPACE
30
SPACE
POST
30
POST
50
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U061CP61 (2) R32U (2) CB130,
Space CB120 70 AJ 6PT
N
LC33N7 32
B U132CP61 R32U CB130, 1 Y2
Space (2) CB120 70 AH 6PT LC33N7 48
C U058CP61 BR54U,
R32U
CB250,
CB130 80 AG 9PT LC33N1 20
Back-to-Back
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
D U061CB61 (2) R32U (2) CB130,
Space CB120 70 AM 6PT
N LC33N1
46
E U132CB61 R32U CB130, 1 Y2
Space (2) CB120 70 AM 6PT 59
F U058CB6 BR54U,
R32U
CB250,
CB130 80 AK 9PT 62
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
* Wire Range Table on page 62.
Midwest Electric Products
Power Outlets
58
Data subject to change without notice.
Power Outlets
Metered
Pedestal, 80 – 100 Amps, 120/240V
Fig. A
R058CP6
BR54U, R32U
Fig. B
M132CP6
R32U
Fig. C
R058CB6
BR54U, R32U
Fig. D
M132CB6
R32U
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A R058CP61 BR54U,
R32U
CB250,
CB130 80
AQ 9PT N LC33N1
59
1 Y2
B M132CP61 R32U CB130,
Space (2) CB120 100 56
Back-to-Back
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
C R058CB61 BR54U,
R32U
CB250,
CB130 80 AT
9PT N LC33N1 82 1 Y2
D M132CB61 R32U CB130,
Space (2) CB120 100 AU
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
* Wire Range Table on page 62.
50 30
POST
50 30
POST
50 30
SPACE
30
SPACE
POST
SPACE
30
SPACE
SPACE
30
SPACE
POST
Midwest Electric Products
Power Outlets
59
Data subject to change without notice.
Power Outlets
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches) Knockout
Meter Socket Post Lugs Height (A) Width (B) Depth (C) Figure2
M132CB6 MSM100P9 LT100B350 9PT See page 61
M132CP6 MSM100P9 LT100S250 9PT See page 61
M354C — — 9 x 30 B 30 9-3/4 5-3/16 6
R058C MSR100930 — 9 x 30 B 30 9-3/4 5-3/16 2
R058CB6 MSR100P9 LT100B350 9PT See page 61
R058CP6 MSR100P9 LT100S250 9PT See page 61
U002C — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U004F — — 14 x 21 A 21-3/8 14-3/4 6-7/16 3
U004CTL010 — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010010GRP — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010C — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U010F — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010H — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010S010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010S010GRP — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U011 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U011010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U011F — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U012010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U012010GRP — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U013 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U013C — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U013F — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U014C010 — — 9 x 17 A 17 9-1/2 5-1/5 2
U014CP6010 — — 9PT See page 61
U023 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U025S — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U041 — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U041010 — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U041C — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U041F — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U050 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U050C — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U051F — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U054 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U054F — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U055010 — — 6 X 9 A 9-1/8 7-1/4 5-3/16 1
U055F — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U058C — — 9 x 17 A 17-3/8 9-1/4 5-3/16 2
U058CB6 — LT100B250 9PT See page 61
U058CP6 — LT100S250 9PT See page 61
U061C — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U061CB6 — LT100B250 6PT See page 61
U061CP6 — LT100S250 6PT See page 61
U061CTL — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U070C — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U075C — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U132CB6 — LT100B250 6PT See page 61
U132CP6 — LT100S250 6PT See page 61
U132CTL — — 9 x 17 A 17-3/8 9-1/4 5-3/16 2
1 Enclosure Styles on page 60.
2 Knockout Figures on page 60.
Midwest Electric Products
Power Outlets
60
Data subject to change without notice.
Power Outlets
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches) Knockout
Meter Socket Post Lugs Height (A) Width (B) Depth (C) Figure2
U239G — — 14 x 21 A 21-3/8 14-1/4 6-7/16 3
U354C — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U361G — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U501 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U511C — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U511G — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U546 — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U550F — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U614C — — 14 x 21 A 21-3/8 14-3/4 6-7/16 3
U666C010 — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U870G6 — — 9 x 21 A 21-5/8 9-1/2 4-3/4 5
1 Enclosure Styles see below.
2 Knockout Figures see below.
Cabinet Dimensions
Fig. A Fig. B
B C
A
B C
A
Knockout Congurations
Fig. 1
Fig. 5
Fig. 2 Fig. 3 Fig. 4
Fig. 6
G G G
G N G
G G G
G G
G
N N
G G G G
F H F
B B
G G
G
H G
G D
C C C C
C
E Q
A C
G G D G
G
G
B B
* Knockouts shown for size not for exact positions.
Knockout Key
A = 1-1/2", 2", 2-1/2"
B = 1", 1-1/4", 1-1/2"
C = 1-1/4", 1-1/2", 2"
D = 3/4", 1", 1-1/4"
E = 3/4"
F =1/2", 3/4"
G = 1/2", 3/4", 1"
H = 1/2", 3/4", 1", 1-1/4"
N = 1/2", 3/4", 1", 1-1/4", 1-1/2"
Q = 1"
Midwest Electric Products
Power Outlets
61
Data subject to change without notice.
Power Outlets
Dimensions Key
A = Post Length
B = Meter Center to Grade
C = Terminal Bar to Grade
D = Post Width
E = Post Depth
F = Grade to Wire Opening
G = Wire Opening
Single Head Post
Single Head Post
Single Head Post
Double Head Post
(Back-to-Back)
Double Head Post
(Back-to-Back)
Double Head Post
(Back-to-Back)
Key Unmetered
A 62"
C 19-3/4"
D 6-1/2"
E 3-1/4"
F 18"
G 6"
Key Unmetered Metered
A 86" 86"
B — 50"
C 49-1/2" 49-1/2"
D 14" 14"
E 4-3/8" 4-3/8"
F 18" 18"
G 6" 6"
Key Unmetered Metered
A 64-1/2" 77-1/2"
B — 45-1/4"
C 19-1/8" 19-1/8"
D 9" 9"
E 3-1/4"1 3-1/4"1
F 18" 18"
G 6" 6"
1 Some models available in 4-3/8".
Contact distributor/factory.
9PT 9PT
6PT
14PT
Post Dimensions
Earth Burial
Single Head Post
Single Head Post
Double Head Post
(Back-to-Back)
Double Head Post
(Back-to-Back)
Key Unmetered
A 36"
C 17-3/4"
D 6-1/2"
E 3-3/4"
Key Unmetered Metered
A 41-1/8" 53-1/2"
B — 45-1/2"
C 19-3/4" 19-1/2"
D 9" 9"
E 3-1/4"1 3-1/4"1
1 Some models available in 4-3/8".
Contact distributor/factory.
6PT
Pad Mount
Midwest Electric Products
Power Outlets
62
Data subject to change without notice.
Power Outlets
Wire Range Tables
A
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-6 12-8 12-6
Load — — — —
Neutral 12-8 12-6 12-8 12-6
Equipment Ground 12-8 12-2 12-8 12-2
AD
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load — — — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
AG
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load — — — —
Neutral 14-4 14-4 14-4 14-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 1-300 kcmil 1-300 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AH
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral 14-4 14-4 14-4 14-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 1-300 kcmil 1-300 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AJ
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 14-1/0 14-1/0
Equipment Ground 12-2 12-2 12-2 12-2
AK
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load — — — —
Neutral 12-8 12-1/0 10-8 10-1/0
Neutral 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 6-350 kcmil 6-350 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AM
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 2-250 kcmil 2-250 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AQ
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load — — — —
Neutral 14-4 14-4 14-4 14-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 1-300 kcmil 1-300 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AT
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load — — — —
Neutral 12-8 12-1/0 10-8 10-1/0
Neutral 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 6-350 kcmil 6-350 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AU
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load — — — —
Neutral 12-8 12-1/0 10-8 10-1/0
Neutral 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 2-250 kcmil 2-250 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
B
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-6 12-8 12-6
Load 14-10 14-10 — —
Neutral 12-8 12-6 12-8 12-6
Equipment Ground 12-8 12-2 12-8 12-2
E
Connector
Copper
Solid Strand
Line 14-10 14-10
Load 14-10 14-10
Neutral 14-10 14-10
Equipment Ground 12-8 12-2
Midwest Electric Products
Power Outlets
63
Data subject to change without notice.
Power Outlets
Wire Range Tables
F
Connector
Copper
Solid Strand
Line 14-10 14-10
Load — —
Neutral 14-10 14-10
Equipment Ground 12-8 12-2
G
Connector
Copper
Solid Strand
Line 12-8 12-4
Load — —
Neutral 12-8 12-4
Equipment Ground 12-8 12-2
J
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-10 14-10 — —
Load 14-10 14-10 — —
Neutral 14-10 14-10 — —
Equipment Ground 12-8 12-2 12-8 12-2
K
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load 14-10 14-10 — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
L
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-3 12-8 12-3
Load 14-10 14-10 — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
M
Connector
Copper
Solid Strand
Line 12-8 12-4
Load 14-10 14-10
Neutral 12-8 12-4
Equipment Ground 12-8 12-2
Line - FH2 Fuseholder 14-10 14-10
Neutral 14-10 14-10
N
Connector
Copper Aluminum
Solid Strand Solid Strand
Line - Meter Socket — 1-300 — —
Load - Base Lugs — — — —
Neutral - Large Single Lug — 1-300 — 1-300
Neutral - Small Single Lug 14-8 14-1/0 12-8 12-1/0
Neutral - Large Hole 14-8 10-4 — 6-4
Neutral - Small Hole 14-8 12-8 12-8 12-8
Equipment Ground - Large Hole 12-8 12-1/0 12-1/0 10-1/0
Equipment Ground - Small Hole 14-8 14-4 12-10 12-4
O
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
P
Connector
Copper
Solid Strand
Line 12-8 12-4
Load — —
Neutral — —
Equipment Ground 12-8 12-2
Q
Connector
Copper
Solid Strand
Line 14-8 14-1/0
Load 14-10 14-10
Neutral - Large Hole 12-8 12-1/0
Neutral - Small Hole 14-8 14-4
Equipment Ground 12-8 12-2
R
Connector
Copper Aluminum
Solid Strand Solid Strand
Line - Switch 14-10 14-10 — —
Equipment Ground 12-8 12-2 12-8 12-2
Line - Receptacle 14-10 14-10 — —
Load - Receptacle 14-10 14-10 — —
Neutral - Receptacle 14-10 14-10 — —
U
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load 14-10 14-10 — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
V
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load — — — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Data subject to change without notice.
Midwest Electric Products
64
Spa Panels
Midwest Electric Products
Spa Panels
65
Data subject to change without notice.
Spa Panels
Application Information
GFI disconnects provide a convenient, low-cost means,
to satisfy National Electric Code requirements for a
GFI disconnect for spas, hot tubs, water heaters and
swimming pools. The NEMA 3R design insures a safe,
weather-tight installation. All units come fully assembled
and factory wired. Midwest is your best choice for quality
outdoor disconnects.
Features and Benets
? Extra circuit breaker spaces allow for future expansion
? Fully assembled unit saves costly installation time
? NEMA 3R weatherproof enclosures
? G90 galvanized steel construction for superior
corrosion protection
? Durable polyester powder coat finish resists chipping
and fading
? 125A rating
? All terminals accept copper or aluminum wire for
installation flexbility
? Includes both overcurrent and ground fault protection
? Overhead hub opening
? Padlock provision to prevent unauthorized access
Fig. Model Number1 Extra Breaker
Spaces
GFI Protection
(Amps)
Amps
Hub
Opening
Lug Wire Size
Cu/Al
UL
A UG412RMW250
2 or 4
50
125 Y 6-2/0 Y2
B UG412RMW260 60
1 Unit includes appropriate GFI Breaker.
2 cULus approved.
Cabinet Dimensions Knockout Congurations
C
C
A
E
* Knockouts shown for size not for exact positions.
Knockout Key
A = 1/2
C = 1/2", 3/4", 1"
E = 3/4", 1-1/4", 1-1/2"
GFI Disconnect
125 Amps, 120/240V
UG412RMW250
UG412RMW260
7.5” 4”
10”
Fig. A
UG412RMW250
Fig. B
UG412RMW260
SPACE
SPACE
50
SPACE
SPACE
60
Midwest Electric Products
66
RV Park Equipment
Midwest Electric Products
RV Park Equipment
67
Data subject to change without notice.
RV Park Equipment
RV Park Equipment
Successful camp ground owners provide their campers
with the amenities that keep them coming back year
after year: fun, recreation, relaxation, clean and well
maintained facilities, friendly staff, and last but not least,
hassle free RV hookups! That’s where Midwest Electric
Products comes in. Midwest offers a complete line of
RV power outlets designed with both the camper and
the campground owner in mind.
Camper Safety
? Designed and tested to stringent UL safety standards
? Personal protection against ground faults is accomplished
via GFCI circuit breaker or receptacle (your choice)
? Duplex outlets are weather resistant and tamper resistant
? In-use covers and grade panels prevent cord and
incoming cable abrasion
? Painted dead front panel separates the camper from all
electrical wiring
? Power units and access panels can be padlocked to
prevent unauthorized access/use
Customer Convenience
? RV power outlets are offered with a wide range of
receptacle and circuit breaker combinations
? Power heads provide stay-open, in-use cover
? Convenience features include: light, TV, cable
and water connections
Installation and Maintenance
? Installation and maintenance ease, durability, and
aesthetics
? Factory wired circuit breakers and receptacles
? Surface mounted power heads have ample concentric
knockouts
? Pedestal models are equipped with factory installed
loop feed lugs to accommodate down-stream power
outlets
? All mechanical lugs are rated for copper and aluminum
wire, including the factory installed equipment ground
lug
? G90 galvanized steel which provides superior corrosion
protection and years of trouble free maintenance
? Durable, fade resistant, polyester powder coat paint
finish that is baked on for extra protection
If you’re a long-time Midwest RV power outlet customer,
thank you for your continued business (many of our
repeat customers have been buying from Midwest for
over thirty years). If you’re new to Midwest, welcome.
We’ll do our best to make you a believer in all Midwest
Electric Products.
Metallic RV ParkMate?
Data subject to change without notice.
Midwest Electric Products
RV Equipment – Metallic
68
RV Equip – Metallic
Midwest Electric Products
RV Equipment – Metallic
69
Data subject to change without notice.
RV Equip – Metallic
Application Information
Midwest Metallic RV power centers are a cost effective
favorite among campground owners seeking to offer the
essential amenities to their campers while keeping their
upfront and lifetime costs to a minimum. All components
are factory assembled and wired to reduce installation
time. The power centers are manufactured using heavy
gauge galvanized steel that are top-coated with a durable
power coat finish for years of maintenance free operation.
These dependable power centers are available in either
single-sided or double-sided construction and have a
variety of circuit protection, receptacles and convenience
options available. Mounting options include surface
mount, pad mount, or earth burial post. This versatility
gives campground owners the features that their
campers expect.
Features and Benets
Rugged Durability
? Rolled edge door for cord protection
? All-in-one construction for factory assured terminations
? G90 galvanized steel construction for superior
corrosion and fading resistance
? Welded flange NEMA 3R construction for lasting
service in outdoor installations
? 10kAIC
Installation Ease
? All components factory wired and assembled, reducing
installation time
? Door has stay open position for user convenience
? All terminals accept copper or aluminum wire for added
installation flexibility
? Wide range of receptacle configurations
? Broad range of concentric knockouts to accommodate
varied wiring needs
? Post door removable for installation ease
User Safety
? Dead front construction prevents accidental contact
with live parts
? Padlock provision to prevent unauthorized access
? GFCI weather and tamper resistant GFI receptacles
? Rolled edge post bottoms to protect incoming
service cable
Midwest Electric Products
RV Equipment – Metallic
70
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Surface, 20 Amps, 120V
Surface, 70 – 80 Amps, 120/240V
Fig. H
U055C010
BR54U, 5-20R2GFCI
Fig. C
U011C010
(2) 5-20R2GFCI
Fig. A
U010C010
5-20R2GFCI
Fig. B
U010G
5-20R2
Fig. I
U055G
BR54U, 5-20R2
Fig. D
U011G
(2) 5-20R2
Fig. J
U412G
BR32U, (2) 5-20R2
Fig. E
U040G
R32U, 5-20R2
Fig. K
U611CTL010
(2) BR32U, 5-20R2GFCI
Fig. F
U041C010
R32U, 5-20R2GFCI
Fig. L
U611GTL
(2) BR32U, 5-20R2
Fig. G
U041G
R32U, 5-20R2
GFI
20 20
GFI
50 20
GFI
GFI GFI
SPACE
20 20
20
GFI
20
GFI
30
SPACE
20
GFI
30
GFI
30 30 20
GFI
SPACE
30 20
GFI
30 20
GFI
30
SPACE
20
GFI
30
50 20
GFI
SPACE
20
GFI
20
GFI
Fig. Model Number Receptacles Circuit Protection Amps Lug Type
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U010C010 5-20R2GFCI CB120
20 Standard B 6 x 9 Y — 7 4 Y1
B U010G 5-20R2 GFI120
1 cULus approved.
* Wire Range Table on page 91.
Fig. Model Number Receptacles Circuit Protection Amps Lug Type
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
C U011C010 (2) 5-20R2GFCI (2) CB120,
Space CB120 70 Standard P 6 x 14
Y
LC33N7 10 4
Y1
D U011G (2) 5-20R2 (2) GFI120,
Space CB120 70 Standard P 6 x 14 LC33N7 10 4
E U040G R32U,
5-20R2
GFI130, GFI120,
Space CB120 70 Standard P 6 x 14 LC33N7 10 4
F U041C010 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 70 Standard P 6 x 14 LC33N7 10 4
G U041G R32U,
5-20R2
CB130, GFI120,
Space CB120 70 Standard P 6 x 14 LC33N7 10 4
H U055C010 BR54U,
5-20R2GFCI
CB250,
CB120 70 Standard P 6 x 14 LC33N7 10 4
I U055G BR54U,
5-20R2
CB250,
GFI120 70 Standard P 6 x 14 LC33N7 10 4
J U412G BR32U,
(2) 5-20R2
CB130,
(2) GFI120 70 Standard U 9 x 17 LC33N1 16 1
K U611CTL010 (2) BR32U,
5-20R2GFCI
(2) CB130,
CB120 80 Loop Feed W 9 x 17 LC33N1T 16 1
L U611GTL (2) BR32U,
5-20R2
(2) CB130,
GFI120 80 Loop Feed W 9 x 17 LC33N1T 15 1
1 cULus approved.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
71
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Surface, 100 – 125 Amps, 120/240V
Fig. A
U011CTL010
(2) 5-20R2GFCI
Fig. F
U041GTL
BR32U, 5-20R2
Fig. B
U011GTL
(2) 5-20R2
Fig. G
U074GTL
BR54U, R32U, 5-20R2
Fig. L
U355C010
BR54U, 5-20R2GFCI
Fig. K
U131CTL010
(2) BR32U, (2) 5-20R2GFCI
Fig. C
U031C010
R32U, (2) 5-20R2GFCI
Fig. H
U075CTL010
BR54U, R32U, 5-20R2GFCI
Fig. M
U355G
BR54U, 5-20R2
Fig. D
U040GTL
R32U, 5-20R2
Fig. I
U075GTL
BR54U, R32U, 5-20R2
Fig. N
U775C010
(2) 14-50R, BR32U, 5-20R2GFCI
Fig. E
U041CTL010
R32U, 5-20R2GFCI
Fig. J
U076C010
BR54U, (2) 5-20R2GFCI
SPACE
20 20
GFI GFI
SPACE
20
GFI
30
SPACE
30 30 20
SPACE
GFI GFI
50 30
SPACE
20
GFI
20 50
GFI
SPACE
SPACE
SPACE
20
GFI
30
GFI
50 30
SPACE
20
GFI
30 20 50 50
GFI
SPACE
30 20
GFI
50 20
SPACE
20
GFI GFI
SPACE
20
GFI
20
GFI
50 30
GFI
SPACE
20
GFI
50 20
SPACE
SPACE
GFI
30
SPACE
20 30 20
GFI GFI
Fig. Model Number Receptacles Circuit Protection Amps Lug Type
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U011CTL010 (2) 5-20R2GFCI (2) CB120,
Space CB120 100 Loop Feed W 9 x 17
Y
LC33N1T 14
1
Y1
B U011GTL (2) 5-20R2 (2) GFI120,
Space CB120 100 Loop Feed W 9 x 17 LC33N1T 14
C U031C010 R32U,
(2) 5-20R2GFCI
CB130, (2) CB120,
Space (2) CB120 100 Standard AA 9 x 17 LC55N1 16
D U040GTL R32U,
5-20R2
GFI130, GFI120,
Space CB120 100 Loop Feed W 9 x 17 LC33N1T 14
E U041CTL010 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100 Loop Feed W 9 x 17 LC33N1T 14
F U041GTL BR32U,
5-20R2
CB130, GFI120,
Space CB120 100 Loop Feed W 9 x 17 LC33N1T 14
G U074GTL BR54U, R32U,
5-20R2
CB250, GFI130,
GFI120, Space CB120 100 Loop Feed W 9 x 17 LC55N1T 16 Y
H U075CTL010 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 Loop Feed W 9 x 17 LC55N1T 16
Y1
I U075GTL BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 Loop Feed W 9 x 17 LC55N1T 16
J U076C010 BR54U,
(2) 5-20R2GFCI
CB250, (2) CB120,
Space CB120 100 Standard U 9 x 17 LC55N1 16
K U131CTL010 (2) BR32U,
(2) 5-20R2GFCI
(2) CB130, (2) CB120,
Space CB120 100 Loop Feed U 14 x 21 LC55N1T 28
L U355C010 BR54U,
5-20R2GFCI
CB250, CB120,
(2) Spaces 100A Max 100 Standard U 9 x 17 LC55N1 16
M U355G BR54U,
5-20R2
CB250, GFI120,
(2) Spaces 100A Max 100 Standard U 9 x 17 LC55N1 15
N U775C010 (2) 14-50R, BR32U,
5-20R2GFCI
(2) CB250T, CB130,
CB120T 125 Standard W 9 x 17 — 15
1 cULus approved.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
72
Data subject to change without notice.
RV Equip – Metallic
Metered
Surface, 70 – 120 Amps, 120/240V
Fig. A
M055C010, R055C010
BR54U, 5-20R2GFCI
Fig. G
M075C010, R075C010
BR54U, BR32U, 5-20R2GFCI
Fig. H
M075G
BR54U, BR32U, 5-20R2
Fig. I
M355C010
BR54U, 5-20R2GFCI
Fig. J
M355G, R355G
BR54U, 5-20R2
Fig. K
M004C010
(2) BR54U, 5-20R2GFCI
Fig. B
M055G, R055G
BR54U, 5-20R2
Fig. C
M076C010, R076C010
BR54U, (2) 5-20R2GFCI
Fig. D
M031C010, R031C010
R32U, (2) 5-20R2GFCI
Fig. E
M041C010, R041C010
BR32U, 5-20R2GFCI
Fig. F
M041G, R041G
BR32U, 5-20R2
50 20
GFI
50 30
GFI
SPACE
20
50 20
GFI
50 30
SPACE
20
GFI
50 20
GFI
SPACE
SPACE
50 20
GFI GFI
SPACE
20 30 20 20
GFI GFI
SPACE
SPACE
30 20
GFI
SPACE
50 20 50
GFI
50 20
GFI
SPACE
SPACE
30 20
GFI
SPACE
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M055C010 R055C010 BR54U,
5-20R2GFCI
CB250,
CB120 70
AA 9 x 30 Y
LC33N1 25
1 Y1
B M055G R055G BR54U,
5-20R2
CB250,
GFI120 70 LC33N1 25
C M076C010 R076C010 BR54U,
(2) 5-20R2GFCI
CB250, (2) CB120,
Space CB120 90 LC55N1 26
D M031C010 R031C010 R32U,
(2) 5-20R2GFCI
CB130, (2) CB120,
(2) SPACE CB120 100 LC55N1 25
E M041C010 R041C010 BR32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100 LC33N1 24
F M041G R041G BR32U,
5-20R2
CB130, GFI120,
Space CB120 100 LC33N1 25
G M075C010 R075C010 BR54U, BR32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 LC55N1 25
H M075G — BR54U, BR32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 LC55N1 25
I M355C010 — BR54U,
5-20R2GFCI
CB250, CB120,
(2) Space CB120 100 LC55N1 25
J M355G R355G BR54U,
5-20R2
CB250, GFI120,
(2) Space CB120 100 LC55N1 25
K M004C010 — (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 LC55N1 26
1 cULus approved.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
73
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, 30 Amps, 120V
Fig. A
U042GP6
R32U, 5-20R2
Fig. C
U011GP6, U011GP4
(2) 5-20R2
Fig. H
U043GP6
R32U, 5-20R2
Fig. D
U040GP6, U040GP4
R32U, 5-20R2
Fig. I
U055CP6010, U055CP4010
BR54U, 5-20R2GFCI
Fig. E
U040GP6010
R32U, 5-20R2GFCI
Fig. J
U412CP6010
BR32U, (2) 5-20R2GFCI
Fig. F
U041CP6010, U041CP4010
R32U, 5-20R2GFCI
Fig. K
U412GP6
BR32U, (2) 5-20R2
Fig. B
U011CP6010, U011CP4010
(2) 5-20R2GFCI
Fig. G
U041GP6, U041GP4
R32U, 5-20R2
30
GFI
30 20
POST
POST
20
GFI
SPACE
20
GFI
30
Main
30 20
GFI
POST
POST
30
GFI
SPACE
20
GFI
POST
50 20
GFI
POST
30
GFI
SPACE
20
GFI
POST
30 20 20
GFI GFI
POST
30
SPACE
20
GFI
POST
30 20
GFI
20
GFI
POST
20
SPACE
20
GFI GFI
POST
30
SPACE
20
GFI
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
A U042GP6 — R32U, 5-20R2 GFI130 Main,
CB130, CB120 30 T2 6PT N LC33N7 32 1 Y1
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
B U011CP6010 U011CP4010 (2) 5-20R2GFCI (2) CB120,
Space CB120
70 T2
6PT
N
LC33N7 32
1 Y1
C U011GP6 U011GP4 (2) 5-20R2 (2) GFI120,
Space CB120 6PT LC33N7 32
D U040GP6 U040GP4 R32U,
5-20R2
GFI130, GFI120,
Space CB120 9PT LC33N7 32
E U040GP6010 — R32U,
5-20R2GFCI
GFI130, CB120,
Space CB120 9PT LC33N7 32
F U041CP60102 U041CP40102 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 6PT LC33N7 32
G U041GP6 U041GP4 R32U,
5-20R2
CB130, GFI120,
Space CB120 6PT LC33N7 32
H U043GP6 — R32U,
5-20R2
CB130, GFI120,
CB130 Main 6PT LC33N7 32
I U055CP6010 U055CP4010 BR54U,
5-20R2GFCI
CB250,
CB120 6PT LC33N7 32
J U412CP6010 — BR32U,
(2) 5-20R2GFCI
CB130,
(2) CB120 9PT LC33N1 47
K U412GP6 — BR32U,
(2) 5-20R2
CB130,
(2) GFI120 9PT LC33N1 51
1 cULus approved.
2 Available with factory installed TV/Telephone. Replace “010” with “031”.
See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
1 cULus approved.
* Wire Range Table on page 91.
Pedestal, 70 Amps, 120/240V
Midwest Electric Products
RV Equipment – Metallic
74
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, 80 – 125 Amps, 120/240V
Fig. A
U611CP6010, U611CP4010
(2) BR32U, 5-20R2GFCI
Fig. F
U131CP6010
(2) BR32U, (2) 5-20R2GFCI
Fig. G
U175CP6HP010
BR54U, BR32U, 5-20R2GFCI
Fig. H
U355GP6
BR54U, 5-20R2
Fig. I
U004CP6010, U004CP4010
(2) BR54U, 5-20R2GFCI
Fig. J
U775CP6010, U775CP4010
(2) 14-50R, BR32U, 5-20R2GFCI
Fig. B
U075CP6010, U075CP4010
BR54U, BR32U, 5-20R2GFCI
Fig. C
U075CP6010D
BR54U, BR32U, 5-20R2GFCI
Fig. D
U075GP6, U075GP4
BR54U, BR32U, 5-20R2
Fig. E
U075GP6019
BR54U, BR32U, 5-20R2
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
A U611CP6010 U611CP4010 (2) BR32U,
5-20R2GFCI
(2) CB130,
CB120 80 T2 9PT
N
LC33N1 47
1
Y
B U075CP6010 2 U075CP4010 2,3 BR54U, BR32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 T2 9PT LC55N1 47
Y1
C U075CP6010D 4 — BR54U, BR32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 T2 9PT LC55N1 47
D U075GP6 U075GP4 BR54U, BR32U,
5-20R2
CB250, CB130,
GFI120 100 T2 9PT LC55N1 47
E U075GP6019 — BR54U, BR32U,
5-20R2
CB250, GFI130,
GFI120 100 T2 9PT LC55N1 47
F U131CP6010 — (2) BR32U,
(2) 5-20R2GFCI
(2) CB130, (2) CB120,
Space CB120 100 T2 14PT LC55N1 47
G U175CP6HP010 — BR54U, BR32U,
5-20R2GFCI
CB2100 Main, CB250,
CB130, CB120 100 W 14PT 198B8627G14 89
H U355GP6 — BR54U,
5-20R2
CB250, GFI120,
(2) Space 100A Max 100 T2 9PT LC55N1 47
I U004CP6010 U004CP40102 (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 T2 9PT LC55N1 47
J U775CP6010 U775CP4010 (2) 14-50R, BR32U,
5-20R2GFCI
(2) CB250T, CB130,
CB120T 125 T2 9PT 265A6250G34 97
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”.
See page 88-89 for TV/Telephone model diagrams.
3 Available in bronze paint – add “ZI” after model number.
4 Post depth dimension is non-standard (4-3/8").
* Wire Range Table on page 91.
POST
30 30 20
GFI
POST
SPACE
20
GFI GFI
30 30 20
POST
SPACE
50 30
GFI
20
POST
30 30 50
GFI
SPACE
SPACE
100
Main
POST
SPACE
50 30
GFI
20
POST
SPACE
SPACE
50 20
GFI
POST
SPACE
50 30 20
GFI
POST
50 20 50
GFI
POST
SPACE
50 30
GFI
20
GFI
POST
30 20 50 50
GFI
Midwest Electric Products
RV Equipment – Metallic
75
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, Earth Burial, 125 Amps, 120/208V
Fig. A
5S3S2S2SES
BR54U, BR32U, (2) 5-20R2GFCI
Fig. C
5S3S2S2SEB
BR54U, BR32U, (2) 5-20R2GFCI
Fig. D
5S3S3S2SEB
BR54U, (2) BR32U, 5-20R2GFCI
Fig. B
5S3S3S2SES
BR54U, (2) BR32U, 5-20R2GFCI
3-Phase
Fig. Model Number Receptacles Circuit Protection Sides Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A 5S3S2S2SES BR54U, BR32U,
(2) 5-20R2GFCI
CB250, GFI130,
(2) CB120
1 125 6-350
kcmil2 14PT N 3-Phase,
4 Wire — 1 Y1
B 5S3S3S2SES BR54U, (2) BR32U,
5-20R2GFCI
CB250, (2) GFI130,
CB120
3-Phase, Back-to-Back
Fig. Model Number Receptacles Circuit Protection Sides Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
C 5S3S2S2SEB BR54U, BR32U,
(2) 5-20R2GFCI
CB250, GFI130,
(2) CB120
2 125 6-350
kcmil2 14PT N 3-Phase,
4 Wire — 1 Y1
D 5S3S3S2SEB BR54U, (2) BR32U,
5-20R2GFCI
CB250, (2) GFI130,
CB120
1 cULus approved.
2 Loop Lugs – Line/Neutral/Ground.
* Wire Range Table on page 91.
POST
30 50
GFI
20 20
GFI GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
POST
30 50
GFI
20 30
GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
POST
30 50
GFI
20 20
GFI GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
20 20 30 50
GFI GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
POST
30 50
GFI
20 30
GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
30 50
GFI
20 30
GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
Midwest Electric Products
RV Equipment – Metallic
76
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, Back-to-Back, 30 Amps, 120V
Fig. A
U042GB
R32U, 5-20R2
Fig. B
U011GB6, U011GB4
(2) 5-20R2
Fig. C
U041CB6010, U041CB4010
R32U, 5-20R2GFCI
Fig. D
U041GB6, U041GB4
R32U, 5-20R2
Fig. E
U055GB6
BR54U, 5-20R2
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
B U011GB6 U011GB4 (2) 5-20R2 (2) GFI120,
Space CB120
70 T2 6PT N LC33N7 47 1 Y1
C U041CB6010 U041CB4010 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120
D U041GB6 U041GB4 R32U,
5-20R2
CB130, GFI120,
Space CB120
E U055GB6 — BR54U,
5-20R2
CB250,
GFI120
1 cULus approved.
* Wire Range Table on page 91.
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
A U042GB6 — R32U,
5-20R2
GFI130 Main,
(2) CB120 30 T2 6PT N LC33N7 47 1 Y1
* Wire Range Table on page 91.
Pedestal, Back-to-Back, 70 Amps, 120/240V
30
GFI
Main
30 20
POST
30
GFI
Main
30 20
POST
20
GFI
SPACE
20
GFI
20
GFI
SPACE
20
GFI
POST
30
SPACE
20
GFI
30
SPACE
20
GFI
POST
30
SPACE
20
GFI
30
SPACE
20
GFI
POST
50 20
GFI
50 20
GFI
Midwest Electric Products
RV Equipment – Metallic
77
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, Back-to-Back, 80 – 120 Amps, 120/240V
Fig. A
U611CB6010, U611CB4010
(2) R32U, 5-20R2GFCI
Fig. B
U075CB6010, U075CB4010
BR54U, R32U, 5-20R2GFCI
Fig. C
U075GB6
BR54U, R32U, 5-20R2
Fig. D
U004CB6010, U004CB4010
(2) BR54U, 5-20R2GFCI
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
A U611CB6010 U611CB4010 (2) R32U,
5-20R2GFCI
(2) CB130,
CB120 80 T2 9PT
N
LC33N1
62 1 Y1
B U075CB60102 U075CB40102 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 S 9PT LC55N1
C U075GB6 — BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 S 9PT LC55N1
D U004CB6010 U004CB4010 (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 S 9PT LC55N1
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
POST
30 30 20
GFI
30 30 20
GFI
POST
SPACE
50 30 20
SPACE
50 30 20
GFI GFI
POST
SPACE
50 30 20
GFI
SPACE
50 30 20
GFI
POST
50 20 50 50 20 50
GFI GFI
Midwest Electric Products
RV Equipment – Metallic
78
Data subject to change without notice.
RV Equip – Metallic
Metered
Pedestal, Earth Burial, 70 – 100 Amps, 120/240V
Fig. A
M055GP6
BR54U, 5-20R2
Fig. E
M075GP6, R075GP6
BR54U, R32U, 5-20R2
Fig. B
M041CP6010, R041CP6010
R32U, 5-20R2GFCI
Fig. F
M355CP6010, R355CP6010
BR54U, 5-20R2GFCI
Fig. C
M041GP6, R041GP6
R32U, 5-20R2
Fig. G
M355GP6, R355GP6
BR54U, 5-20R2
Fig. D
M075CP6010, R075CP6010
BR54U, R32U, 5-20R2GFCI
Fig. H
M358CP6
BR54U, R32U
POST
30 20
GFI
SPACE
POST
20 50
SPACE
SPACE
GFI
POST
SPACE
50 30
GFI
20
POST
50 30
POST
50 20
GFI
POST
SPACE
50 30 20
GFI
POST
30 20
GFI
SPACE
POST
20 50
GFI
SPACE
SPACE
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M055GP6 — BR54U,
5-20R2
CB250,
GFI120 70
T2 9PT
N LC33N1 59
1 Y1
B M041CP6010 R041CP6010 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100 N LC33N1 53
C M041GP6 R041GP6 R32U,
5-20R2
CB130, GFI120,
Space CB120 100 N LC33N1 59
D M075CP60102 R075CP60102 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 N LC55N1 59
E M075GP6 R075GP6 BR54U,R32U,
5-20R2
GFI120,
Space CB120 100 N LC55N1 59
F M355CP6010 R355CP60102 BR54U,
5-20R2GFCI
CB250, CB120,
(2) Space CB120 100 Y LC55N1 59
G M355GP6 R355GP6 BR54U,
5-20R2
CB250, GFI120,
(2) Space CB120 100 N LC55N1 59
H M358CP6 — BR54U,
R32U
CB250,
CB130 100 N LC55N1 53
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
79
Data subject to change without notice.
RV Equip – Metallic
Metered
Pedestal, Earth Burial, 120 – 200 Amps, 120/240V
Fig. A
M004CP6010
(2) BR54U, 5-20R2GFCI
Fig. D
M655GP6
BR54U, 5-20R2
Fig. C
M275CP6010
BR54U, BR32U, 5-20R2GFCI
Fig. B
M775CP6010
(2) BR54U, BR32U, 5-20R2GFCI
Fig. E
M675CP6010
BR54U, BR32U, 5-20R2GFCI
Fig. F
R255CP6010
BR54U, 5-20R2GFCI
POST
30 20 50 50
GFI
POST
50 20 30 GFI
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
50 20 50
GFI
POST
POST
20 50
GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
POST
50 30 20
GFI
SPACE
SPACE
SPACE
200 MAIN
SPACE
GFI
SPACE
200
MAIN
SPACE
SPACE
SPACE SPACE
LOAD
20 50
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M004CP6010 — (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 T2 9PT N LC55N1 48
1
Y1
B M775CP6010 — (2) BR54U, BR32U,
5-20R2GFCI
(2) CB250T, CB130,
CB120T 125 T2 9PT N — 59
C M275CP60102 — BR54U, BR32U,
5-20R2GFCI
CB2200B Main,
CB250, CB130, CB120 200 BX 14PT N LC1212PC 89
D M655GP6 — BR54U,
5-20R2
CB250, GFI120, Space
CB2200B, Space (5)
CB120 200A Max
200 T2 14PT N LC1212PC 85
E M675CP6010 — BR54U, BR32U,
5-20R2GFCI
CB250, CB130,
CB120 200 BY 14PT N LC1212PC 87
F — R255CP6010 BR54U,
5-20R2GFCI
CB2200B, CB250,
CB120 200 S 14PT Y LC1212PC 88 N
1 cULus approved.
2 Available in green paint – order as M275CP6010G1.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
80
Data subject to change without notice.
RV Equip – Metallic
Metered
Pedestal, Earth Burial, Back-to-Back, 100 – 200 Amps, 120/240V
Fig. A
M041CB6010
R32U, 5-20R2GFCI
Fig. E
M355GB6
BR54U, 5-20R2
Fig. B
M041GB6, R041GB6
R32U, 5-20R2
Fig. F
M775CB6010
(2) BR54U, BR32U, 5-20R2GFCI
Fig. C
M075CB6010, R075CB6010
BR54U, R32U, 5-20R2GFCI
Fig. G
M655GB6
BR54U, 5-20R2
Fig. D
M075GB6, R075GB6
BR54U, R32U, 5-20R2
Fig. H
R255CB6010
BR54U, 5-20R2GFCI
POST
30 20
GFI
SPACE
30 20
GFI
SPACE
POST
50 20
GFI
SPACE
SPACE
50 20
GFI
SPACE
SPACE
POST
30 20
GFI
SPACE
30 20
GFI
SPACE
POST
30 20 50 50
GFI
30 20 50 50
GFI
POST
20 50
GFI
SPACE
SPACE
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
20 50
GFI
SPACE
SPACE
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
POST
SPACE
50 30
GFI
20
SPACE
50 30
GFI
20
POST
SPACE
50 30 20
GFI
SPACE
50 30 20
GFI
GFI
SPACE
200
MAIN
SPACE
SPACE
SPACE SPACE
LOAD
20 50
GFI
SPACE
200
MAIN
SPACE
SPACE
SPACE SPACE
LOAD
20 50
POST
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M041CB6010 — R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100
S
9PT N LC33N1 82
1
Y1
B M041GB6 R041GB6 R32U,
5-20R2
CB130, GFI120,
Space CB120 100 9PT N LC33N1 82
C M075CB60102 R075CB6010 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 9PT N LC55N1 82
D M075GB6 R075GB6 BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 9PT N LC55N1 82
E M355GB6 — BR54U,
5-20R2
CB250, GFI120,
(2) Space CB2100 100 9PT N LC55N1 82
F M775CB6010 — (2) BR54U, BR32U,
5-20R2GFCI
(2) CB250T,
CB130, CB120T 125 9PT N — 82
G M655GB6 — BR54U,
5-20R2
CB250, GFI120,
(9) Space CB120 200 14PT N LC12122PC,
N1200A4 80
H — R255CB6010 BR54U,
5-20R2GFCI
CB2200B,
CB250, CB120 200 14PT Y LC12122PC 101 N
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
81
Data subject to change without notice.
RV Equip – Metallic
Metered
Pedestal, Pad Mount, 100 Amps, 120/240V
Fig. B
M041GP4
R32U, 5-20R2
Fig. D
M075GP4
BR54U, R32U, 5-20R2
Fig. A
M041CP4010
R32U, 5-20R2GFCI
Fig. F
M075CB4010
BR54U, R32U, 5-20R2GFCI
Fig. C
M075CP4010, R075CP4010
BR54U, R32U, 5-20R2GFCI
Fig. E
M355GP4
BR54U, 5-20R2
POST
SPACE
50 30
GFI
20
SPACE
50 30
GFI
20
POST
SPACE
50 30
GFI
20
POST
20 50
GFI
SPACE
SPACE POST
30 20
GFI
SPACE
POST
SPACE
50 30 20
GFI
POST
30 20
GFI
SPACE
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M041CP4010 — R32U,
5-20R2GFCI
CB130, CB120,
Space CB120
100 T2 9PT N
LC33N1 53
1 Y1
B M041GP4 — R32U,
5-20R2
CB130, GFI120,
Space CB120 LC33N1 59
C M075CP4010 R075CP4010 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 LC55N1 59
D M075GP4 — BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 LC55N1 59
E M355GP4 — BR54U,
5-20R2
CB250, GFI120,
Space CB2100 LC55N1 59
Back-to-Back
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
F M075CB4010 — BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 S 9PT N LC55N1 82 1 Y1
1 cULus approved.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
82
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Lighted, Surface 100 Amps, 120/240V
Metered
Lighted, Pedestal, 100 Amps, 120/240V
Fig. D
M075CP6L10, M075CP4L10
BR54U, R32U, 5-20R2GFCI
Fig. B
U075CTLL10
BR32U, R32U, 5-20R2
Fig. C
M041CP6L10, M041CP4L10
R32U, 5-20R2GFCI
Fig. A
U041CTLL10
R32U, 5-20R2GFCI
POST
SPACE
50 30
GFI
20
GFI
50 30
SPACE
20
GFI
POST
30 20
SPACE
GFI
SPACE
30 20
GFI
Fig. Model Number Receptacles Circuit Protection Amps Lug Type
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U041CTLL10 R32U,
5-20R2GFCI
CB130,
CB120
100 Loop Feed W 9 x 17 N
LC33N1T 14
1 Y1
B U075CTLL10 BR32U, R32U
5-20R2GFCI
CB250, CB130,
Space CB120 LC55N1T 16
1 cULus approved.
* Wire Range Table on page 91.
Light Socket Assembly.
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
C M041CP6L10 M041CP4L102 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120
100 T2 9PT Y
LC33N1 50
1 Y1
D M075CP6L102,3 M075CP4L102 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 LC55N1 59
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
3 Available with 350 MCM loop lugs – replace “010” with “039”.
* Wire Range Table on page 91.
Light Socket Assembly.
Midwest Electric Products
RV Equipment – Metallic
83
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Lighted, Pedestal, 70 – 100 Amps, 120/240V
Fig. B
U041CP6L10, U041CP6L10
R32U, 5-20R2GFCI
Fig. D
U075CB6L10, U075CB4L10
BR54U, R32U, 5-20R2GFCI
Fig. A
U041CB6L10, U041CB4L10
R32U, 5-20R2GFC
Fig. C
U041GP6L, U041GP4L
BR54U, R32U, 5-20R2
Fig. E
U075CP6L10, U075GP4L
BR54U, R32U, 5-20R2GFCI
POST
30
SPACE
20
GFI
30
SPACE
20
GFI
POST
SPACE
50 30
GFI
20
SPACE
50 30
GFI
20
POST
30
SPACE
20
GFI
POST
SPACE
50 30
GFI
20
POST
30
SPACE
20
GFI
POST
SPACE
50 30 20
GFI
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A U041CB6L10 U041CB4L10 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 70 T2 6PT
N
LC33N1 42
1 Y1
B U041CP6L10 U041CP4L10 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 70 T2 6PT LC33N1 30
C U041GP6L U041GP4L BR54U, R32U,
5-20R2
CB130, GFI120, Space
CB120, CB250, CB130 70 T2 6PT LC33N1 30
D U075CB6L10 U075CB4L10 BR54U, R32U,
5-20R2GFCI
CB120, Space CB120,
CB250, CB130 100 S 9PT LC55N1 62
E U075CP6L102 U075CP4L102 BR54U, R32U,
5-20R2GFCI
CB120,
Space CB120 100 T2 9PT LC55N1 36
F U075GP6L U075GP4L BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 T2 9PT LC55N1 62
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
Light Socket Assembly.
Fig. F
UO75GP6L
BR54U, R32U, 5-20R2
Midwest Electric Products
RV Equipment – Metallic
84
Data subject to change without notice.
RV Equip – Metallic
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches)3 Knockout
Meter Socket Post Lugs Height (A) Width (B) Depth (C) Figure2
5S3S2S2SEB — LT100B350 14PT — — —
5S3S2S2SES — LT100S250 14PT — — —
5S3S3S2SEB — LT100B350 14PT — — —
5S3S3S2SES — LT100S250 14PT — — —
M004C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M004CP6010 MSM100P9 LT100S300 9PT — — —
M031C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M041C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M041CB6010 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M041CP4010 MSM100P9 LT100S300 9PT — — —
M041CP4L10 MSM100P9 LT100S250 9PT — — —
M041CP4L31 MSM100P9 LT100S300 9PT — — —
M041CP6010 MSM100P9 LT100S300 9PT — — —
M041CP6L10 MSM100P9 LT100S250 9PT — — —
M041G MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M041GB6 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M041GP4 MSM100P9 LT100S250 9PT — — —
M041GP6 MSM100P9 LT100S300 9PT — — —
M055C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M055G MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M055GP6 MSM100P9 LT100S250 9PT — — —
M075C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M075CB4010 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M075CB6010 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M075CB6031 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M075CP4010 MSM100P9 LT100S300 9PT — — —
M075CP4L10 MSM100P9 LT100S300 9PT — — —
M075CP4L31 MSM100P9 LT100S300 9PT — — —
M075CP6010 MSM100P9 LT100S300 9PT — — —
M075CP6031 MSM100P9 LT100S300 9PT — — —
M075CP6L10 MSM100P9 LT100S300 9PT — — —
M075CP6L31 MSM100P9 LT100S300 9PT — — —
M075CP6L39 MSM100P9 LT100S350 9PT — — —
M075G MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M075GB6 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M075GP4 MSM100P9 LT100S250 9PT — — —
M075GP6 MSM100P9 LT100S250 9PT — — —
M076C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M275CP6010 —6 LT200S350 14PT — — —
M355C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M355CP6010 MSM100P9 LT100S300 9PT — — —
M355G MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M355GB6 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M355GP4 MSM100P9 LT100S300 9PT — — —
M355GP6 MSM100P9 LT100S300 9PT — — —
M358CP6 MSM100P9 LT100B350 9PT — — —
M655GB6 MW200M LT200B350 14PT — — —
M655GP6 MW200M LT200S350 14PT — — —
M675CP6010/G1 —6 LT200S350 14PT — — —
M775CB6010 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M775CP6010 MSM100P9 LT100S250 9PT — — —
R031C010 MSR100930 — 9 x 30 B 30 9-3/4 5-3/16 2
R041C010 MSR100930 — 9 x 30 B 30 9-3/4 5-3/16 2
R041CP6010 MSR100P9 LT100S300 9PT — — —
R041G MSR100930 — 9 x 30 B 30 9-3/4 5-3/16 2
R041GB6 MSR100P9, MSR100HP5 LT100B350 9PT B — —
R041GP6 MSR100P9 LT100S250 9PT — — —
1 Enclosure Styles on page 87.
2 Knockout Figures on page 87.
Temporary Power
Metered
Top Feed, 40 – 90 Amps, 120/240V
Fig. A
M036C010, R036C010
6-20R, 5-20R2GFCI
Fig. G
M055C033, R055C033
BR54U, 5-20R2GFCI
Fig. H
M055G, R055G
BR54U, (2) 5-20R2
Fig. I
M055GP6033
BR54U, 5-20R2
Fig. J
M076C010, R076C010
BR54U, (2) 5-20R2GFCI
Fig. K
M076C033, R076C033
BR54U, (2) 5-20R2GFCI
Fig. B
M036C033
6-20R, 5-20R2GFCI
Fig. C
M036G, R036G
6-20R, 5-20R2
Fig. D
M051C010
10-50R, 5-20R2GFCI
Fig. E
M051G
10-50R, 5-20R2
Fig. F
M055C010, R055C010
BR54U, 5-20R2GFCI
20 20
GFI
50
GFI
20
GFI
20 20
GFI
GFI
50 20
GFI
20 20
GFI
50
GFI
20
GFI
POST
50 20
GFI
50 20
GFI
50
GFI
20 20
GFI GFI
50 20
GFI GFI
SPACE
20
50 20
GFI
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ringtype Ringless
A M036C010 R036C010 6-20R,
5-20R2GFCI
CB220,
CB120 40 AA 9 x 30
Y
LC33N1 25
1
B M036C033 — 6-20R, Y2
5-20R2GFCI
GFI230,
CB120 40 AA 9 x 30 LC33N1 23
C M036G R036G 6-20R,
5-20R2
CB220,
GF1120 40 AA 9 x 30 LC33N1 25
D M051C010 — 10-50R,
5-20R2GFCI
CB250,
CB120 70 AA 9 x 30 LC33N1 25
N
E M051G — 10-50R,
5-20R2
CB250,
GF1120 70 AA 9 x 30 LC33N1 25
F M055C010 R055C010 BR54U,
5-20R2GFCI
CB250,
CB120 70 K 9 x 30 LC33N1 25
Y2
G M055C033 R055C033 BR54U,
5-20R2GFCI
GFI250,
CB120 70 K 9 x 30 LC33N1 23
H M055G R055G BR54U,
5-20R2
CB250,
GFI120 70 AA 9 x 30 LC33N1 25
I M055GP60331 — BR54U,
5-20R2
GFI120,
GFI250 70 A2 9 PT LC33N1 51
J M076C010 R076C010 BR54U,
(2) 5-20RGFCI
CB250, (2) CB120,
Space CB120 90 AA 9 x 30 LC55N1 25
K M076C033 R076C033 BR54U,
(2) 5-20RGFCI
GFI250, (2) CB120,
Space CB120 90 AA 9 x 30 LC55N1 25
1 Earth Burial Post. See page 90 for post mounted dimensions.
2 cULus approved.
* Wire Range Table on page 49.
Midwest Electric Products
Temporary Power
44
Data subject to change without notice.
Temporary Power
Metered
Top Feed, 100 Amps, 120/240V
Fig. B
M011G, R011G
(2) 5-20R2
Fig. A
M011C010, R011C010
(2) 5-20R2GFCI
Fig. C
M038C010, R038C010
6-20R, (2) 5-20R2GFCI
Fig. E
M038CB1010
6-20R, (2) 5-20R2GFCI
Fig. D
M038C033, R038C033
6-20R, (2) 5-20R2GFCI
Fig. F
M038CB1033
6-20R, (2) 5-20R2GFCI
Fig. G
R038CP4010
6-20R, (2) 5-20R2GFCI
GFI GFI
SPACE
20 20
SPACE
20
GFI
20
GFI
20
GFI
20
GFI GFI
SPACE
20 20
GFI
20
GFI GFI
SPACE
20
BARRIER
20 20
GFI GFI
SPACE
20 20 20
GFI GFI
SPACE
20
BARRIER
20 20
GFI GFI
SPACE
20
POST
Fig. H
R038CP4033
6-20R, (2) 5-20R2GFCI
20
GFI
20
GFI GFI
SPACE
20
POST
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ringtype Ringless
A M011C010 R011C010 (2) 5-20R2GFCI (2) CB120,
Space CB120 100 AA 9 x 30
Y
LC33N1 21 1
Y2
B M011G R011G (2) 5-20R2 (2) GFI120,
Space CB120 100 AA 9 x 30 LC33N1 21 1
C M038C010 R038C010 6-20R,
(2) 5-20R2GFCI
CB220, (2) CB120,
Space CB120 100 AA 9 x 30 LC55N1 25 1
D M038C033 R038C033 6-20R,
(2) 5-20R2GFCI
GFI220, (2) CB120,
Space CB120 100 AA 9 x 30 LC55N1 24 1
E M038CB1010 — 6-20R,
(2) 5-20R2GFCI
CB220, (2) CB120,
Space CB120 100 AA 14 x 26 LC55N1 33 1
Y
F M038CB1033 — 6-20R,
(2) 5-20R2GFCI
GFI220, (2) CB120,
Space CB120 100 AA 14 x 26 LC55N1 33 1
G — R038CP40101 6-20R,
(2) 5-20R2GFCI
CB220, (2) CB120,
Space CB120 100 A2 9 PT LC55N1 45 1
H — R038CP40331 Y2 6-20R,
(2) 5-20R2GFCI
GFI220, (2) CB120,
Space CB120 100 A2 9 PT LC55N1 45 1
I M038G R038G 6-20R,
(2) 5-20R
CB220, (2) GFI120,
Space CB120 100 AA 9 x 30 LC55N1 25 4
J M038GB1 — 6-20R,
(2) 5-20R
CB220, (2) GFI120,
Space CB120 100 AA 14 x 26 LC55N1 35 1
Y
K M038GB1033 — 6-20R,
(2) 5-20R2
GFI220, (2) GFI120,
Space CB120 100 AA 14 x 26 LC55N1 35 1
1 Pad Mount Post. See page 90 for post mounted dimensions.
2 cULus approved.
* Wire Range Table on page 49.
Fig. J
M038GB1
6-20R, (2)5-20R
Fig. K
M038GB1033
6-20R, (2)5-20R
20 20
GFI
SPACE
20
GFI
BARRIER
20
GFI
20
GFI
SPACE
20
GFI
BARRIER
Fig. I
M038G, R038G
6-20R, (2)5-20R
SPACE
20
GFI
20
GFI
20
Midwest Electric Products
Temporary Power
45
Data subject to change without notice.
Temporary Power
Metered
Bottom Feed, 40 – 100 Amps, 120/240V
Fig. A
M036C010U
6-20R, 5-20R2GFCI
Fig. G
M038C010U, R038C010U
6-20R, (2) 5-20R2GFCI
Fig. B
M055C010U, R055C010U
BR54U, 5-20R2GFCI
Fig. H
M038C033U, R038C033U
6-20R, (2) 5-20R2GFCI
Fig. C
M055C033U, R055C033U
BR54U, 5-20R2GFCI
Fig. I
R038GU
6-20R, (2) 5-20R2
Fig. D
M076C010U, R076C010U
BR54U, (2) 5-20R2GFCI
Fig. J
M041C010U
R32U, 5-20R2GFCI
Fig. E
M011C010U, R011C010U
(2) 5-20R2GFCI
Fig. K
M075C010U, R075C010U
BR54U, R32U, 5-20R2GFCI
Fig. F
R031C010U
R32U, (2) 5-20R2GFCI
Fig. L
M355C010U
BR54U, 5-20R2GFCI
20 20
GFI
20 20
GFI GFI
SPACE
20
50 20
GFI
20
GFI
20
GFI GFI
SPACE
20
50 20
GFI
GFI
20 20
GFI
20
GFI
SPACE
30 20
GFI
SPACE
50 30 20
GFI
SPACE
50 20
GFI
SPACE
SPACE
50 20
GFI GFI
SPACE
20
GFI GFI
SPACE
20 20 30 20 20
GFI GFI
SPACE
SPACE
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ringtype Ringless
A M036C010U — 6-20R,
5-20R2GFCI
CB220,
CB120 40 X 9 x 30U N LC33N1 25
1 Y1
B M055C010U R055C010U BR54U,
5-20R2GFCI
CB250,
CB120 70 H 9 x 30U N LC33N1 25
C M055C033U R055C033U BR54U,
5-20R2GFCI
GFI250,
CB120 70 H 9 x 30U Y LC33N1 23
D M076C010U R076C010U BR54U,
(2) 5-20R2GFCI
CB250, (2) CB120,
Space CB120 90 X 9 x 30U N LC55N1 25
E M011C010U R011C010U (2) 5-20R2GFCI (2) CB120,
Space CB120 100 X 9 x 30U N LC33N1 21
F — R031C010U R32U,
(2) 5-20R2GFCI
CB130,
(2) CB120 100 AA 9 x 30U Y LC55N1 25
G M038C010U R038C010U 6-20R,
(2) 5-20R2GFCI
CB220, (2) CB120,
Space CB120 100 X 9 x 30U N LC55N1 25
H M038C033U R038C033U 6-20R,
(2) 5-20R2GFCI
GF1220, (2) CB120,
Space CB120 100 X 9 x 30U Y LC55N1 26
I — R038GU 6-20R,
(2) 5-20R2
CB220,
(2) GFI120 100 X 9 x 30U N LC55N1 25
J M041C010U — R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100 AA 9 x 30U Y LC33N1 25
K M075C010U R075C010U BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, (1) Space 100 AA 9 x 30U Y LC55N1 25
L M355C010U — BR54U,
5-20R2GFCI
CB250, CB120,
(2) Space CB120 100 AA 9 x 30U Y LC55N1 25
1 cULus approved.
* Wire Range Table on page 49.
Midwest Electric Products
Temporary Power
46
Data subject to change without notice.
Temporary Power
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches) Knockout
Meter Socket Height (A) Width (B) Depth (C) Figure2
M011C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M011C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M011G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M036C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M036C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M036C033 MSM100930 9 X 30 B 30 9-3/4 5-3/16 2
M036G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M038C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M038C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M038C033 MSM100930 9 X 30 B 30 9-3/4 5-3/16 2
M038C033U MSM100EZ 9 X 30U C 30 9-3/4 5-3/16 3
M038CB1010 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4
M038CB1033 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4
M038G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M038GB1 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4
M038GB1033 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4
M041C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
M051C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M051G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M055C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M055C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M055C033 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M055C033U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M055G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M055GP6033 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M075C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
M076C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M076C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
M076C033 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2
M355C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
R011C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R011C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R011G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R031C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
R036C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R036C010U MSR100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R036G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R038C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R038C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R038C033 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R038C033U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R038CP4010 MSR100EZ 9 PT B 30 9-3/4 5-3/16 2
R038CP4033 MSR100EZ 9 PT B 30 9-3/4 5-3/16 2
R038G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R038GU MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R055C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R055C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R055C033 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R055C033U MSM100EZ 9 X 30U C 30 9-3/4 5-3/16 3
R055G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R075C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4
R076C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2
R076C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3
R076C033 MSR100930 9 X 30 B 30 9-3/4 5-3/16 2
1 Enclosure Styles on page 47.
2 Knockout Figures on page 48.
Midwest Electric Products
Temporary Power
47
Data subject to change without notice.
Temporary Power
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches) Knockout
Meter Socket Height (A) Width (B) Depth (C) Figure2
U011C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U011G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U011GTL — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U030 — 5 x 7 A 7-1/8 5-3/4 5-3/16 1
U036C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U036C033 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U036G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U038C010 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U038C033 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U038CTL010 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U038CTL033 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U038G — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U039G6 — 9 x 21 D 21 9-3/4 5-3/16 5
U051C — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U051C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U051C033 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U051G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U054C — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U055C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U055C033 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U055G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1
U072C — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U073G — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U076C010 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U076C033 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U076G — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
1 Enclosure Styles on page 47.
2 Knockout Figures on page 48.
Cabinet Dimensions
Fig. A
Fig. D
Fig. B Fig. C
B C
A
B C
A
B C
A
A
B C
Midwest Electric Products
Temporary Power
48
Data subject to change without notice.
Temporary Power
Knockout Congurations
Fig. 1
Fig. 4
Fig. 2 Fig. 3
Fig. 5
G G G G
G N G
P P P
W W
A
G G G
N N
G
G G
G W B
G
G
G
G D
B B
G
* Knockouts shown for size not for exact positions.
Knockout Key
A = 1/2"
B = 1", 1-1/4", 1-1/2"
D = 3/4", 1", 1-1/4"
G = 1/2", 3/4", 1"
N = 1/2", 3/4", 1", 1-1/4", 1-1/2"
P = 1/2", 3/4", 1", 1-1/4", 1-1/2", 2", 2-1/2"
W = 1/2", 3/4", 1", 1-1/4", 2"
Midwest Electric Products
Temporary Power
49
Data subject to change without notice.
Temporary Power
Wire Range Tables
AA
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load 14-10 14-10 — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
A2
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load 14-10 14-10 — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors
Suitable for Loop Feed 2-250 kcmil 2-250 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
C
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 1-300 — 1-300
Ground - Large Hole 12-8 12-1/0 12-10 10-1/0
Ground - Small Hole 14-8 14-4 12-10 10-1/0
Neutral - Large Hole 14-1/0 14-1/0 14-1/0 14-1/0
Neutral - Small Hole 14-6 14-6 14-6 14-6
G
Connector
Copper
Solid Strand
Line 12-8 12-4
Load — —
Neutral 12-8 12-4
Equipment Ground 12-8 12-2
H
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load 14-10 14-10 — —
Neutral — 6-350 — 6-350
Neutral — 1-300 — 1-300
Equipment Ground 12-8 12-2 12-8 12-2
K
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load 14-10 14-10 — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
O
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
U
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load 14-10 14-10 — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
V
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load — — — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
X
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load 14-10 14-10 — —
Neutral — 6-350 — 6-350
Neutral — 1-300 — 1-300
Equipment Ground 12-8 12-2 12-8 12-2
Data subject to change without notice.
Midwest Electric Products
50
Power Outlets
Midwest Electric Products
Power Outlets
51
Data subject to change without notice.
Power Outlets
Application Information
Portable equipment requiring electricity continues to
increase steadily in both number and variety. This creates
the need for conveniently located receptacles to provide
power for cord connected equipment. Midwest Electric
Power Outlets provide one or more receptacles, with or
without overcurrent protection, in a single enclosure,
eliminating the need for several separately mounted
components while providing maximum protection
against weather and normal field use. Additionally, many
models also include disconnecting, metering, and/or
pedestal mounting functions in a single NEMA 3R
enclosure/assembly.
Features and Benets
? NEMA 3R weatherproof construction
? G90 galvanized steel construction for superior
corrosion resistance
? Durable polyester powder coat finish resists chipping
and fading
? All in one construction for factory assured terminations
? Rolled edge door for cord protection
? Cover design allows cords to exist while maintaining
the NEMA 3R integrity
? Wide assortments of concentric knockouts offer flexibility
in the installation
? All GFCI duplexes are listed as weather resistant and
tamper resistant as required by NEC in Article 406.8
and 406.11
? Padlockable door to help prevent unauthorized access
? Dead front construction prevents accidental contact
with live parts
? All components factory wired and assembled
U013
U014C010
Midwest Electric Products
Power Outlets
52
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 20 – 30 Amps, 120V
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U010 5-20R2 — 20 E 5 x 7
Y
— 4.5
4 Y1
B U010F 5-20R2 FH2 20 E 5 x 7 — 4.5
C U010H 5-20R2 FH2,
SP Switch 20 E 5 x 7 — 5
D U010010 5-20R2GFCI — 20 E 5 x 7 — 4.5
E U011 (2) 5-20R2 — 20 E 5 x 7 — 4.5
F U011010 (2) 5-20R2GFCI — 20 E 5 x 7 — 4.5
F U012010 (2) 5-20R2GFCI — 20 E 5 x 7 N — 4.5
G U013 R32U — 30 F 5 x 7
Y
— 4.5
H U013C R32U CB130 30 A 6 x 9 LC31N3 7
I U013F R32U FH3 30 F 5 x 7 — 4.5
1 cULus approved.
* Wire Range Table on page 62-63.
Fig. A
U010
5-20R2
Fig. F
U011010, U012010
(2) 5-20R2GFCI
Fig. B
U010F
5-20R2
Fig. D
U010010
5-20R2GFCI
Fig. H
U013C
R32U
Fig. C
U010H
5-20R2
Fig. G
U013
R32U
Fig. E
U011
(2) 5-20R2
Fig. I
U013F
R32U
GFI
GFI GFI 30
Midwest Electric Products
Power Outlets
53
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 20 – 50 Amps, 120/240V
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U010C 5-20R2 CB120 20 B 6 x 9
Y
LC31N3 7
4
Y2
B U011F (2) 5-20R2 (2) FH2 20 E 6 x 9 — 9
C U023 7310 — 20 F 5 x 7 — 4.5 N
D U041 R32U,
5-20R2 — 30 E 6 x 9 — 6
E U041F R32U, Y2
5-20R2 FH3, FH2 30 E 6 x 9 — 7
F U041010 R32U,
5-20R2GFCI — 30 J 6 x 9 — 9
G U050 10-50R — 50 G 5 x 7 — 4.5
N
H U051F 10-50R,
5-20R2 FH2 50 K 6 x 14 FR66 10
I U054 BR54U — 50 G 5 x 7 — 5
Y2
J U054F BR54U — 50 O 6 x 14 FR67 10
K U055010 BR54U,
5-20R2GFCI — 50 J 6 x 9 — 9
L U055F BR54U,
5-20R2 — 50 L 6 x 14 FR66, FH2 9
M U061C1 (2) R32U (2) CB130,
Space CB120 50 O 6 x 14 LC33N7 10
N U550F BR54U,
5-20R2 FH2 50 M 6 x 14 — 6
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
* Wire Range Table on page 62-63.
Surface, 50 Amps, 240V
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
O U501 6-50R — 50 P 5 x 7 Y — 5 4 Y
* Wire Range Table on page 63.
Fig. A
U010C
5-20R2
Fig. I
U054
BR54U
Fig. B
U011F
(2) 5-20R2
Fig. J
U054F
BR54U
Fig. D
U041
R32U, 5-20R2
Fig. F
U041010
R32U, 5-20R2GFCI
Fig. L
U055F
BR54U, 5-20R2
Fig. N
U550F
BR54U, 5-20R2
Fig. C
U023
7310
Fig. K
U055010
BR54U, 5-20R2GFCI
Fig. E
U041F
R32U, 5-20R2
Fig. G
U050
10-50R
Fig. H
U051F
10-50R, 5-20R2
Fig. M
U061C
(2) R32U
Fig. O
U501
6-50R
20
GFI
30 30
SPACE
GFI
Midwest Electric Products
Power Outlets
54
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 60 – 100 Amps, 120/240V
Fig. A
U546
14-60R
Fig. F
U511G
6-50R, 5-20R2
Fig. G
U666C010
10-30R, (2) 5-20R2GFCI
Fig. H
U058C
BR54U, BR32U
Fig. I
U070C
10-50R, 7310, 5-20R2
Fig. B
U041C
R32U, 5-20R2
Fig. C
U050C
10-50R
Fig. D
U361G
(2) 5-20R2
Fig. E
U511C
6-50R, 5-20R2
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U546 14-60R — 60 G 6 x 9
Y
— 5
4
N
B U041C R32U,
5-20R2
CB130, CB120,
Space CB120 70 K 6 x 14 LC33N7 10 Y2
C U050C 10-50R CB250,
Space CB120 70 O 6 x 14 LC33N7 10 N
D U361G (2) 5-20R2 GFI120 70 K 6 x 14 LC33N7 9 Y2
E U511C 6-50R,
5-20R2
CB250,
CB120 70 K 6 x 14 LC33N7 10 Y2
F U511G 6-50R,
5-20R2
CB250,
GFI120 70 K 6 x 14 LC33N7 10 Y2
G U666C010 10-30R,
(2) 5-20R2GFCI
CB230, (2) CB120,
Space CB120 70 U 9 x 17 LC55N1 16
1
N
H U058C1 BR54U,
BR32U
CB250,
CB130 80 V 9 x 17 LC33N1 15 Y2
I U070C 10-50R, 7310,
5-20R2
CB250, CB220,
CB120 90 U 9 x 17 LC55N1 16 N
J U002C (2) 10-50R,
5-20R2
(2) CB250,
CB120 100 U 14 x 21 LC55N1 31 N
K U132CTL R32U CB130,
Space (2) CB120 100 V 9 x 17 LC33N1T 11 Y2
L U014C0103 (4) 5-20R2GFCI (4) CB120,
Space CB120 100 U 9 x 17 LC55N1 28 Y2
M U061CTL (2) R32U (2) CB130,
Space CB120 100 O 9 x 17 LC33N1T 14 Y2
N U075C BR54U, R32U,
5-20R2
CB250, CB130,
CB120, Space CB120 100 U 9 x 17 LC55N1 16 Y2
O U354C BR54U CB250,
Space (3) CB120 100 V 9 x 17 LC55N1 16 Y2
P U614C1 (2) R32U,
(2) BR32U
(4) CB130,
Space CB120 100 V 14 x 21 LC55N1 30 Y2
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
3 Earth Burial Model U014CP6010.
* Wire Range Table on page 63.
50 20
GFI
30
SPACE
20 20
SPACE
30 20
GFI GFI
SPACE
50 20 50 30
GFI
SPACE
SPACE
50 20 20
GFI
50 20
Fig. J
U002C
(2) 10-50R, 5-20R2
Fig. K
U132CTL
R32U
Fig. M
U061CTL
(2) R32U
Fig. O
U354C
BR54U
Fig. L
U014C010
(4) 5-20R2GFCI
Fig. N
U075C
BR54U, R32U, 5-20R2
Fig. P
U614C
(2) R32U, (2) BR32U
50 50 20 SPACE
30
SPACE
20 20 20 20
GFI GFI GFI GFI
SPACE
30 30
SPACE
30 20
SPACE
50
SPACE
SPACE
SPACE
50 30 30 30 30
SPACE
Midwest Electric Products
Power Outlets
55
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 120 – 200 Amps, 120/240V
Metered
Surface, 80 – 100 Amps, 120V/240V
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U004CTL010 (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 U 9 x 17
Y
LC55N1T 17
1 Y1
B U004F (2) BR54U,
5-20R2 FH2 120 U 14 x 21 FR64X2 30
C U870G6 L6-30R,
(2) L5-20R
GFI230, (2) GFI120,
Space CB120 125 Q 9 x 21 LC1212PC 16
D U239G L6-30R,
(2) L5-20R
GFI230,
(2) GFI120 200 N 14 x 21 LC1212PC 30
1 cULus approved.
* Wire Range Table on page 63.
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
E R058C1 BR54U,
R32U
CB250,
CB130 80 AD 9 x 30
Y
LC33N1
25 1 Y2
F M354C BR54U CB250,
SPACE (3) CB120 100 AD 9 x 30 LC55N1
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
* Wire Range Table on page 62.
Fig. B
U004F
(2) BR54U, 5-20R2
Fig. C
U870G6
L6-30R, (2) L5-20R
Fig. E
R058C
BR54U, R32U
Fig. D
U239G
L6-30R, (2) L5-20R
Fig. A
U004CTL010
(2) BR54U, 5-20R2GFCI
Fig. F
M354C
BR54U
SPACE
30
GFI
20
GFI
20
GFI
SPACE
SPACE
SPACE
SPACE SPACE
SPACE SPACE
SPACE
20
GFI
20
GFI
30
GFI
50 20 50
GFI
50 30 50
SPACE
SPACE
SPACE
Midwest Electric Products
Power Outlets
56
Data subject to change without notice.
Power Outlets
Unmetered
Surface, 20 Amps, 120V
Surface, 20 Amps, 240V
Fig. Model Number Receptacles Number of GFI Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Enclosure
Color
Unit
Wt.
Std
Pkg.
UL
A U010010GRP1 5-20R2GFCI 1 20 E
5 x 7 N
Camo
Green 4
1 Y2
B U010S010 5-20R2GFCI,
Switch 1 20 R Gray 4
B U010S010GRP1 5-20R2GFCI,
Switch 1 20 R Camo
Green 3
C U012010GRP1 (2) 5-20R2GFCI 2 20 J Camo
Green 3
Fig. Model Number Receptacles Number of GFI Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Enclosure
Color
Unit
Wt.
Std
Pkg.
UL
D U025S L6-20R Twist Lock,
Switch — 20 R 5 x 7 N Gray 4 4 Y2
1 Available in standard gray paint. U010010, U010S010, U012010 see page 138.
2 cULus approved.
* Wire Range Table on page 62-63.
Fig. B
U010S010, U010S010GRP
5-20R2GFCI, Switch
Fig. C
U012010GRP
(2) 5-20R2GFCI
Fig. D
U025S
L6-20R Twist Lock,
Switch
Fig. A
U010010GRP
5-20R2GFCI
GFI GFI GFI GFI
Midwest Electric Products
Power Outlets
57
Data subject to change without notice.
Power Outlets
Unmetered
Pedestal, 70 – 80 Amps, 120/240V
Fig. A
U061CP6
(2) R32U
Fig. D
U061CB6
(2) R32U
Fig. E
U132CB6
R32U
Fig. F
U058CB6
BR54U, R32U
Fig. B
U132CP6
R32U
Fig. C
U058CP6
BR54U, R32U
30
SPACE
30
POST
30
SPACE
30 30
SPACE
30
POST
SPACE
30
SPACE
POST
SPACE
30
SPACE
30
POST
50 50 30
SPACE
30
SPACE
POST
30
POST
50
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U061CP61 (2) R32U (2) CB130,
Space CB120 70 AJ 6PT
N
LC33N7 32
B U132CP61 R32U CB130, 1 Y2
Space (2) CB120 70 AH 6PT LC33N7 48
C U058CP61 BR54U,
R32U
CB250,
CB130 80 AG 9PT LC33N1 20
Back-to-Back
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
D U061CB61 (2) R32U (2) CB130,
Space CB120 70 AM 6PT
N LC33N1
46
E U132CB61 R32U CB130, 1 Y2
Space (2) CB120 70 AM 6PT 59
F U058CB6 BR54U,
R32U
CB250,
CB130 80 AK 9PT 62
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
* Wire Range Table on page 62.
Midwest Electric Products
Power Outlets
58
Data subject to change without notice.
Power Outlets
Metered
Pedestal, 80 – 100 Amps, 120/240V
Fig. A
R058CP6
BR54U, R32U
Fig. B
M132CP6
R32U
Fig. C
R058CB6
BR54U, R32U
Fig. D
M132CB6
R32U
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A R058CP61 BR54U,
R32U
CB250,
CB130 80
AQ 9PT N LC33N1
59
1 Y2
B M132CP61 R32U CB130,
Space (2) CB120 100 56
Back-to-Back
Fig. Model Number Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
C R058CB61 BR54U,
R32U
CB250,
CB130 80 AT
9PT N LC33N1 82 1 Y2
D M132CB61 R32U CB130,
Space (2) CB120 100 AU
1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC.
2 cULus approved.
* Wire Range Table on page 62.
50 30
POST
50 30
POST
50 30
SPACE
30
SPACE
POST
SPACE
30
SPACE
SPACE
30
SPACE
POST
Midwest Electric Products
Power Outlets
59
Data subject to change without notice.
Power Outlets
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches) Knockout
Meter Socket Post Lugs Height (A) Width (B) Depth (C) Figure2
M132CB6 MSM100P9 LT100B350 9PT See page 61
M132CP6 MSM100P9 LT100S250 9PT See page 61
M354C — — 9 x 30 B 30 9-3/4 5-3/16 6
R058C MSR100930 — 9 x 30 B 30 9-3/4 5-3/16 2
R058CB6 MSR100P9 LT100B350 9PT See page 61
R058CP6 MSR100P9 LT100S250 9PT See page 61
U002C — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U004F — — 14 x 21 A 21-3/8 14-3/4 6-7/16 3
U004CTL010 — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010010GRP — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010C — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U010F — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010H — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010S010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U010S010GRP — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U011 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U011010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U011F — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U012010 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U012010GRP — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U013 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U013C — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U013F — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U014C010 — — 9 x 17 A 17 9-1/2 5-1/5 2
U014CP6010 — — 9PT See page 61
U023 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U025S — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U041 — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U041010 — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U041C — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U041F — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U050 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U050C — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U051F — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U054 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U054F — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U055010 — — 6 X 9 A 9-1/8 7-1/4 5-3/16 1
U055F — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U058C — — 9 x 17 A 17-3/8 9-1/4 5-3/16 2
U058CB6 — LT100B250 9PT See page 61
U058CP6 — LT100S250 9PT See page 61
U061C — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U061CB6 — LT100B250 6PT See page 61
U061CP6 — LT100S250 6PT See page 61
U061CTL — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U070C — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U075C — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U132CB6 — LT100B250 6PT See page 61
U132CP6 — LT100S250 6PT See page 61
U132CTL — — 9 x 17 A 17-3/8 9-1/4 5-3/16 2
1 Enclosure Styles on page 60.
2 Knockout Figures on page 60.
Midwest Electric Products
Power Outlets
60
Data subject to change without notice.
Power Outlets
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches) Knockout
Meter Socket Post Lugs Height (A) Width (B) Depth (C) Figure2
U239G — — 14 x 21 A 21-3/8 14-1/4 6-7/16 3
U354C — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U361G — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U501 — — 5 x 7 A 7-1/8 5-3/4 5-3/16 4
U511C — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U511G — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U546 — — 6 x 9 A 9-1/8 7-1/4 5-3/16 1
U550F — — 6 x 14 A 14-3/8 7-1/4 5-3/16 1
U614C — — 14 x 21 A 21-3/8 14-3/4 6-7/16 3
U666C010 — — 9 x 17 A 17-3/8 9-3/4 5-3/16 2
U870G6 — — 9 x 21 A 21-5/8 9-1/2 4-3/4 5
1 Enclosure Styles see below.
2 Knockout Figures see below.
Cabinet Dimensions
Fig. A Fig. B
B C
A
B C
A
Knockout Congurations
Fig. 1
Fig. 5
Fig. 2 Fig. 3 Fig. 4
Fig. 6
G G G
G N G
G G G
G G
G
N N
G G G G
F H F
B B
G G
G
H G
G D
C C C C
C
E Q
A C
G G D G
G
G
B B
* Knockouts shown for size not for exact positions.
Knockout Key
A = 1-1/2", 2", 2-1/2"
B = 1", 1-1/4", 1-1/2"
C = 1-1/4", 1-1/2", 2"
D = 3/4", 1", 1-1/4"
E = 3/4"
F =1/2", 3/4"
G = 1/2", 3/4", 1"
H = 1/2", 3/4", 1", 1-1/4"
N = 1/2", 3/4", 1", 1-1/4", 1-1/2"
Q = 1"
Midwest Electric Products
Power Outlets
61
Data subject to change without notice.
Power Outlets
Dimensions Key
A = Post Length
B = Meter Center to Grade
C = Terminal Bar to Grade
D = Post Width
E = Post Depth
F = Grade to Wire Opening
G = Wire Opening
Single Head Post
Single Head Post
Single Head Post
Double Head Post
(Back-to-Back)
Double Head Post
(Back-to-Back)
Double Head Post
(Back-to-Back)
Key Unmetered
A 62"
C 19-3/4"
D 6-1/2"
E 3-1/4"
F 18"
G 6"
Key Unmetered Metered
A 86" 86"
B — 50"
C 49-1/2" 49-1/2"
D 14" 14"
E 4-3/8" 4-3/8"
F 18" 18"
G 6" 6"
Key Unmetered Metered
A 64-1/2" 77-1/2"
B — 45-1/4"
C 19-1/8" 19-1/8"
D 9" 9"
E 3-1/4"1 3-1/4"1
F 18" 18"
G 6" 6"
1 Some models available in 4-3/8".
Contact distributor/factory.
9PT 9PT
6PT
14PT
Post Dimensions
Earth Burial
Single Head Post
Single Head Post
Double Head Post
(Back-to-Back)
Double Head Post
(Back-to-Back)
Key Unmetered
A 36"
C 17-3/4"
D 6-1/2"
E 3-3/4"
Key Unmetered Metered
A 41-1/8" 53-1/2"
B — 45-1/2"
C 19-3/4" 19-1/2"
D 9" 9"
E 3-1/4"1 3-1/4"1
1 Some models available in 4-3/8".
Contact distributor/factory.
6PT
Pad Mount
Midwest Electric Products
Power Outlets
62
Data subject to change without notice.
Power Outlets
Wire Range Tables
A
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-6 12-8 12-6
Load — — — —
Neutral 12-8 12-6 12-8 12-6
Equipment Ground 12-8 12-2 12-8 12-2
AD
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load — — — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
AG
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load — — — —
Neutral 14-4 14-4 14-4 14-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 1-300 kcmil 1-300 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AH
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral 14-4 14-4 14-4 14-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 1-300 kcmil 1-300 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AJ
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 14-1/0 14-1/0
Equipment Ground 12-2 12-2 12-2 12-2
AK
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load — — — —
Neutral 12-8 12-1/0 10-8 10-1/0
Neutral 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 6-350 kcmil 6-350 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AM
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 2-250 kcmil 2-250 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AQ
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load — — — —
Neutral 14-4 14-4 14-4 14-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 1-300 kcmil 1-300 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AT
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load — — — —
Neutral 12-8 12-1/0 10-8 10-1/0
Neutral 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 6-350 kcmil 6-350 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
AU
Connector
Copper Aluminum
Solid Strand Solid Strand
Line — 6-1/0 — 6-1/0
Load — — — —
Neutral 12-8 12-1/0 10-8 10-1/0
Neutral 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Post Line Connectors - Loop Feed 2-250 kcmil 2-250 kcmil
Equipment Ground 12-2 12-2 12-2 12-2
B
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-6 12-8 12-6
Load 14-10 14-10 — —
Neutral 12-8 12-6 12-8 12-6
Equipment Ground 12-8 12-2 12-8 12-2
E
Connector
Copper
Solid Strand
Line 14-10 14-10
Load 14-10 14-10
Neutral 14-10 14-10
Equipment Ground 12-8 12-2
Midwest Electric Products
Power Outlets
63
Data subject to change without notice.
Power Outlets
Wire Range Tables
F
Connector
Copper
Solid Strand
Line 14-10 14-10
Load — —
Neutral 14-10 14-10
Equipment Ground 12-8 12-2
G
Connector
Copper
Solid Strand
Line 12-8 12-4
Load — —
Neutral 12-8 12-4
Equipment Ground 12-8 12-2
J
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-10 14-10 — —
Load 14-10 14-10 — —
Neutral 14-10 14-10 — —
Equipment Ground 12-8 12-2 12-8 12-2
K
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load 14-10 14-10 — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
L
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-3 12-8 12-3
Load 14-10 14-10 — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
M
Connector
Copper
Solid Strand
Line 12-8 12-4
Load 14-10 14-10
Neutral 12-8 12-4
Equipment Ground 12-8 12-2
Line - FH2 Fuseholder 14-10 14-10
Neutral 14-10 14-10
N
Connector
Copper Aluminum
Solid Strand Solid Strand
Line - Meter Socket — 1-300 — —
Load - Base Lugs — — — —
Neutral - Large Single Lug — 1-300 — 1-300
Neutral - Small Single Lug 14-8 14-1/0 12-8 12-1/0
Neutral - Large Hole 14-8 10-4 — 6-4
Neutral - Small Hole 14-8 12-8 12-8 12-8
Equipment Ground - Large Hole 12-8 12-1/0 12-1/0 10-1/0
Equipment Ground - Small Hole 14-8 14-4 12-10 12-4
O
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-2 12-8 12-2
Load — — — —
Neutral - End Hole 14-8 14-2 12-8 12-2
Neutral - Side Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
P
Connector
Copper
Solid Strand
Line 12-8 12-4
Load — —
Neutral — —
Equipment Ground 12-8 12-2
Q
Connector
Copper
Solid Strand
Line 14-8 14-1/0
Load 14-10 14-10
Neutral - Large Hole 12-8 12-1/0
Neutral - Small Hole 14-8 14-4
Equipment Ground 12-8 12-2
R
Connector
Copper Aluminum
Solid Strand Solid Strand
Line - Switch 14-10 14-10 — —
Equipment Ground 12-8 12-2 12-8 12-2
Line - Receptacle 14-10 14-10 — —
Load - Receptacle 14-10 14-10 — —
Neutral - Receptacle 14-10 14-10 — —
U
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load 14-10 14-10 — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
V
Connector
Copper Aluminum
Solid Strand Solid Strand
Line 14-8 14-1/0 12-8 12-1/0
Load — — — —
Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0
Neutral - Small Hole 14-8 14-4 12-8 12-4
Equipment Ground 12-8 12-2 12-8 12-2
Data subject to change without notice.
Midwest Electric Products
64
Spa Panels
Midwest Electric Products
Spa Panels
65
Data subject to change without notice.
Spa Panels
Application Information
GFI disconnects provide a convenient, low-cost means,
to satisfy National Electric Code requirements for a
GFI disconnect for spas, hot tubs, water heaters and
swimming pools. The NEMA 3R design insures a safe,
weather-tight installation. All units come fully assembled
and factory wired. Midwest is your best choice for quality
outdoor disconnects.
Features and Benets
? Extra circuit breaker spaces allow for future expansion
? Fully assembled unit saves costly installation time
? NEMA 3R weatherproof enclosures
? G90 galvanized steel construction for superior
corrosion protection
? Durable polyester powder coat finish resists chipping
and fading
? 125A rating
? All terminals accept copper or aluminum wire for
installation flexbility
? Includes both overcurrent and ground fault protection
? Overhead hub opening
? Padlock provision to prevent unauthorized access
Fig. Model Number1 Extra Breaker
Spaces
GFI Protection
(Amps)
Amps
Hub
Opening
Lug Wire Size
Cu/Al
UL
A UG412RMW250
2 or 4
50
125 Y 6-2/0 Y2
B UG412RMW260 60
1 Unit includes appropriate GFI Breaker.
2 cULus approved.
Cabinet Dimensions Knockout Congurations
C
C
A
E
* Knockouts shown for size not for exact positions.
Knockout Key
A = 1/2
C = 1/2", 3/4", 1"
E = 3/4", 1-1/4", 1-1/2"
GFI Disconnect
125 Amps, 120/240V
UG412RMW250
UG412RMW260
7.5” 4”
10”
Fig. A
UG412RMW250
Fig. B
UG412RMW260
SPACE
SPACE
50
SPACE
SPACE
60
Midwest Electric Products
66
RV Park Equipment
Midwest Electric Products
RV Park Equipment
67
Data subject to change without notice.
RV Park Equipment
RV Park Equipment
Successful camp ground owners provide their campers
with the amenities that keep them coming back year
after year: fun, recreation, relaxation, clean and well
maintained facilities, friendly staff, and last but not least,
hassle free RV hookups! That’s where Midwest Electric
Products comes in. Midwest offers a complete line of
RV power outlets designed with both the camper and
the campground owner in mind.
Camper Safety
? Designed and tested to stringent UL safety standards
? Personal protection against ground faults is accomplished
via GFCI circuit breaker or receptacle (your choice)
? Duplex outlets are weather resistant and tamper resistant
? In-use covers and grade panels prevent cord and
incoming cable abrasion
? Painted dead front panel separates the camper from all
electrical wiring
? Power units and access panels can be padlocked to
prevent unauthorized access/use
Customer Convenience
? RV power outlets are offered with a wide range of
receptacle and circuit breaker combinations
? Power heads provide stay-open, in-use cover
? Convenience features include: light, TV, cable
and water connections
Installation and Maintenance
? Installation and maintenance ease, durability, and
aesthetics
? Factory wired circuit breakers and receptacles
? Surface mounted power heads have ample concentric
knockouts
? Pedestal models are equipped with factory installed
loop feed lugs to accommodate down-stream power
outlets
? All mechanical lugs are rated for copper and aluminum
wire, including the factory installed equipment ground
lug
? G90 galvanized steel which provides superior corrosion
protection and years of trouble free maintenance
? Durable, fade resistant, polyester powder coat paint
finish that is baked on for extra protection
If you’re a long-time Midwest RV power outlet customer,
thank you for your continued business (many of our
repeat customers have been buying from Midwest for
over thirty years). If you’re new to Midwest, welcome.
We’ll do our best to make you a believer in all Midwest
Electric Products.
Metallic RV ParkMate?
Data subject to change without notice.
Midwest Electric Products
RV Equipment – Metallic
68
RV Equip – Metallic
Midwest Electric Products
RV Equipment – Metallic
69
Data subject to change without notice.
RV Equip – Metallic
Application Information
Midwest Metallic RV power centers are a cost effective
favorite among campground owners seeking to offer the
essential amenities to their campers while keeping their
upfront and lifetime costs to a minimum. All components
are factory assembled and wired to reduce installation
time. The power centers are manufactured using heavy
gauge galvanized steel that are top-coated with a durable
power coat finish for years of maintenance free operation.
These dependable power centers are available in either
single-sided or double-sided construction and have a
variety of circuit protection, receptacles and convenience
options available. Mounting options include surface
mount, pad mount, or earth burial post. This versatility
gives campground owners the features that their
campers expect.
Features and Benets
Rugged Durability
? Rolled edge door for cord protection
? All-in-one construction for factory assured terminations
? G90 galvanized steel construction for superior
corrosion and fading resistance
? Welded flange NEMA 3R construction for lasting
service in outdoor installations
? 10kAIC
Installation Ease
? All components factory wired and assembled, reducing
installation time
? Door has stay open position for user convenience
? All terminals accept copper or aluminum wire for added
installation flexibility
? Wide range of receptacle configurations
? Broad range of concentric knockouts to accommodate
varied wiring needs
? Post door removable for installation ease
User Safety
? Dead front construction prevents accidental contact
with live parts
? Padlock provision to prevent unauthorized access
? GFCI weather and tamper resistant GFI receptacles
? Rolled edge post bottoms to protect incoming
service cable
Midwest Electric Products
RV Equipment – Metallic
70
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Surface, 20 Amps, 120V
Surface, 70 – 80 Amps, 120/240V
Fig. H
U055C010
BR54U, 5-20R2GFCI
Fig. C
U011C010
(2) 5-20R2GFCI
Fig. A
U010C010
5-20R2GFCI
Fig. B
U010G
5-20R2
Fig. I
U055G
BR54U, 5-20R2
Fig. D
U011G
(2) 5-20R2
Fig. J
U412G
BR32U, (2) 5-20R2
Fig. E
U040G
R32U, 5-20R2
Fig. K
U611CTL010
(2) BR32U, 5-20R2GFCI
Fig. F
U041C010
R32U, 5-20R2GFCI
Fig. L
U611GTL
(2) BR32U, 5-20R2
Fig. G
U041G
R32U, 5-20R2
GFI
20 20
GFI
50 20
GFI
GFI GFI
SPACE
20 20
20
GFI
20
GFI
30
SPACE
20
GFI
30
GFI
30 30 20
GFI
SPACE
30 20
GFI
30 20
GFI
30
SPACE
20
GFI
30
50 20
GFI
SPACE
20
GFI
20
GFI
Fig. Model Number Receptacles Circuit Protection Amps Lug Type
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U010C010 5-20R2GFCI CB120
20 Standard B 6 x 9 Y — 7 4 Y1
B U010G 5-20R2 GFI120
1 cULus approved.
* Wire Range Table on page 91.
Fig. Model Number Receptacles Circuit Protection Amps Lug Type
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
C U011C010 (2) 5-20R2GFCI (2) CB120,
Space CB120 70 Standard P 6 x 14
Y
LC33N7 10 4
Y1
D U011G (2) 5-20R2 (2) GFI120,
Space CB120 70 Standard P 6 x 14 LC33N7 10 4
E U040G R32U,
5-20R2
GFI130, GFI120,
Space CB120 70 Standard P 6 x 14 LC33N7 10 4
F U041C010 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 70 Standard P 6 x 14 LC33N7 10 4
G U041G R32U,
5-20R2
CB130, GFI120,
Space CB120 70 Standard P 6 x 14 LC33N7 10 4
H U055C010 BR54U,
5-20R2GFCI
CB250,
CB120 70 Standard P 6 x 14 LC33N7 10 4
I U055G BR54U,
5-20R2
CB250,
GFI120 70 Standard P 6 x 14 LC33N7 10 4
J U412G BR32U,
(2) 5-20R2
CB130,
(2) GFI120 70 Standard U 9 x 17 LC33N1 16 1
K U611CTL010 (2) BR32U,
5-20R2GFCI
(2) CB130,
CB120 80 Loop Feed W 9 x 17 LC33N1T 16 1
L U611GTL (2) BR32U,
5-20R2
(2) CB130,
GFI120 80 Loop Feed W 9 x 17 LC33N1T 15 1
1 cULus approved.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
71
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Surface, 100 – 125 Amps, 120/240V
Fig. A
U011CTL010
(2) 5-20R2GFCI
Fig. F
U041GTL
BR32U, 5-20R2
Fig. B
U011GTL
(2) 5-20R2
Fig. G
U074GTL
BR54U, R32U, 5-20R2
Fig. L
U355C010
BR54U, 5-20R2GFCI
Fig. K
U131CTL010
(2) BR32U, (2) 5-20R2GFCI
Fig. C
U031C010
R32U, (2) 5-20R2GFCI
Fig. H
U075CTL010
BR54U, R32U, 5-20R2GFCI
Fig. M
U355G
BR54U, 5-20R2
Fig. D
U040GTL
R32U, 5-20R2
Fig. I
U075GTL
BR54U, R32U, 5-20R2
Fig. N
U775C010
(2) 14-50R, BR32U, 5-20R2GFCI
Fig. E
U041CTL010
R32U, 5-20R2GFCI
Fig. J
U076C010
BR54U, (2) 5-20R2GFCI
SPACE
20 20
GFI GFI
SPACE
20
GFI
30
SPACE
30 30 20
SPACE
GFI GFI
50 30
SPACE
20
GFI
20 50
GFI
SPACE
SPACE
SPACE
20
GFI
30
GFI
50 30
SPACE
20
GFI
30 20 50 50
GFI
SPACE
30 20
GFI
50 20
SPACE
20
GFI GFI
SPACE
20
GFI
20
GFI
50 30
GFI
SPACE
20
GFI
50 20
SPACE
SPACE
GFI
30
SPACE
20 30 20
GFI GFI
Fig. Model Number Receptacles Circuit Protection Amps Lug Type
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U011CTL010 (2) 5-20R2GFCI (2) CB120,
Space CB120 100 Loop Feed W 9 x 17
Y
LC33N1T 14
1
Y1
B U011GTL (2) 5-20R2 (2) GFI120,
Space CB120 100 Loop Feed W 9 x 17 LC33N1T 14
C U031C010 R32U,
(2) 5-20R2GFCI
CB130, (2) CB120,
Space (2) CB120 100 Standard AA 9 x 17 LC55N1 16
D U040GTL R32U,
5-20R2
GFI130, GFI120,
Space CB120 100 Loop Feed W 9 x 17 LC33N1T 14
E U041CTL010 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100 Loop Feed W 9 x 17 LC33N1T 14
F U041GTL BR32U,
5-20R2
CB130, GFI120,
Space CB120 100 Loop Feed W 9 x 17 LC33N1T 14
G U074GTL BR54U, R32U,
5-20R2
CB250, GFI130,
GFI120, Space CB120 100 Loop Feed W 9 x 17 LC55N1T 16 Y
H U075CTL010 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 Loop Feed W 9 x 17 LC55N1T 16
Y1
I U075GTL BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 Loop Feed W 9 x 17 LC55N1T 16
J U076C010 BR54U,
(2) 5-20R2GFCI
CB250, (2) CB120,
Space CB120 100 Standard U 9 x 17 LC55N1 16
K U131CTL010 (2) BR32U,
(2) 5-20R2GFCI
(2) CB130, (2) CB120,
Space CB120 100 Loop Feed U 14 x 21 LC55N1T 28
L U355C010 BR54U,
5-20R2GFCI
CB250, CB120,
(2) Spaces 100A Max 100 Standard U 9 x 17 LC55N1 16
M U355G BR54U,
5-20R2
CB250, GFI120,
(2) Spaces 100A Max 100 Standard U 9 x 17 LC55N1 15
N U775C010 (2) 14-50R, BR32U,
5-20R2GFCI
(2) CB250T, CB130,
CB120T 125 Standard W 9 x 17 — 15
1 cULus approved.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
72
Data subject to change without notice.
RV Equip – Metallic
Metered
Surface, 70 – 120 Amps, 120/240V
Fig. A
M055C010, R055C010
BR54U, 5-20R2GFCI
Fig. G
M075C010, R075C010
BR54U, BR32U, 5-20R2GFCI
Fig. H
M075G
BR54U, BR32U, 5-20R2
Fig. I
M355C010
BR54U, 5-20R2GFCI
Fig. J
M355G, R355G
BR54U, 5-20R2
Fig. K
M004C010
(2) BR54U, 5-20R2GFCI
Fig. B
M055G, R055G
BR54U, 5-20R2
Fig. C
M076C010, R076C010
BR54U, (2) 5-20R2GFCI
Fig. D
M031C010, R031C010
R32U, (2) 5-20R2GFCI
Fig. E
M041C010, R041C010
BR32U, 5-20R2GFCI
Fig. F
M041G, R041G
BR32U, 5-20R2
50 20
GFI
50 30
GFI
SPACE
20
50 20
GFI
50 30
SPACE
20
GFI
50 20
GFI
SPACE
SPACE
50 20
GFI GFI
SPACE
20 30 20 20
GFI GFI
SPACE
SPACE
30 20
GFI
SPACE
50 20 50
GFI
50 20
GFI
SPACE
SPACE
30 20
GFI
SPACE
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M055C010 R055C010 BR54U,
5-20R2GFCI
CB250,
CB120 70
AA 9 x 30 Y
LC33N1 25
1 Y1
B M055G R055G BR54U,
5-20R2
CB250,
GFI120 70 LC33N1 25
C M076C010 R076C010 BR54U,
(2) 5-20R2GFCI
CB250, (2) CB120,
Space CB120 90 LC55N1 26
D M031C010 R031C010 R32U,
(2) 5-20R2GFCI
CB130, (2) CB120,
(2) SPACE CB120 100 LC55N1 25
E M041C010 R041C010 BR32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100 LC33N1 24
F M041G R041G BR32U,
5-20R2
CB130, GFI120,
Space CB120 100 LC33N1 25
G M075C010 R075C010 BR54U, BR32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 LC55N1 25
H M075G — BR54U, BR32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 LC55N1 25
I M355C010 — BR54U,
5-20R2GFCI
CB250, CB120,
(2) Space CB120 100 LC55N1 25
J M355G R355G BR54U,
5-20R2
CB250, GFI120,
(2) Space CB120 100 LC55N1 25
K M004C010 — (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 LC55N1 26
1 cULus approved.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
73
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, 30 Amps, 120V
Fig. A
U042GP6
R32U, 5-20R2
Fig. C
U011GP6, U011GP4
(2) 5-20R2
Fig. H
U043GP6
R32U, 5-20R2
Fig. D
U040GP6, U040GP4
R32U, 5-20R2
Fig. I
U055CP6010, U055CP4010
BR54U, 5-20R2GFCI
Fig. E
U040GP6010
R32U, 5-20R2GFCI
Fig. J
U412CP6010
BR32U, (2) 5-20R2GFCI
Fig. F
U041CP6010, U041CP4010
R32U, 5-20R2GFCI
Fig. K
U412GP6
BR32U, (2) 5-20R2
Fig. B
U011CP6010, U011CP4010
(2) 5-20R2GFCI
Fig. G
U041GP6, U041GP4
R32U, 5-20R2
30
GFI
30 20
POST
POST
20
GFI
SPACE
20
GFI
30
Main
30 20
GFI
POST
POST
30
GFI
SPACE
20
GFI
POST
50 20
GFI
POST
30
GFI
SPACE
20
GFI
POST
30 20 20
GFI GFI
POST
30
SPACE
20
GFI
POST
30 20
GFI
20
GFI
POST
20
SPACE
20
GFI GFI
POST
30
SPACE
20
GFI
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
A U042GP6 — R32U, 5-20R2 GFI130 Main,
CB130, CB120 30 T2 6PT N LC33N7 32 1 Y1
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
B U011CP6010 U011CP4010 (2) 5-20R2GFCI (2) CB120,
Space CB120
70 T2
6PT
N
LC33N7 32
1 Y1
C U011GP6 U011GP4 (2) 5-20R2 (2) GFI120,
Space CB120 6PT LC33N7 32
D U040GP6 U040GP4 R32U,
5-20R2
GFI130, GFI120,
Space CB120 9PT LC33N7 32
E U040GP6010 — R32U,
5-20R2GFCI
GFI130, CB120,
Space CB120 9PT LC33N7 32
F U041CP60102 U041CP40102 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 6PT LC33N7 32
G U041GP6 U041GP4 R32U,
5-20R2
CB130, GFI120,
Space CB120 6PT LC33N7 32
H U043GP6 — R32U,
5-20R2
CB130, GFI120,
CB130 Main 6PT LC33N7 32
I U055CP6010 U055CP4010 BR54U,
5-20R2GFCI
CB250,
CB120 6PT LC33N7 32
J U412CP6010 — BR32U,
(2) 5-20R2GFCI
CB130,
(2) CB120 9PT LC33N1 47
K U412GP6 — BR32U,
(2) 5-20R2
CB130,
(2) GFI120 9PT LC33N1 51
1 cULus approved.
2 Available with factory installed TV/Telephone. Replace “010” with “031”.
See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
1 cULus approved.
* Wire Range Table on page 91.
Pedestal, 70 Amps, 120/240V
Midwest Electric Products
RV Equipment – Metallic
74
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, 80 – 125 Amps, 120/240V
Fig. A
U611CP6010, U611CP4010
(2) BR32U, 5-20R2GFCI
Fig. F
U131CP6010
(2) BR32U, (2) 5-20R2GFCI
Fig. G
U175CP6HP010
BR54U, BR32U, 5-20R2GFCI
Fig. H
U355GP6
BR54U, 5-20R2
Fig. I
U004CP6010, U004CP4010
(2) BR54U, 5-20R2GFCI
Fig. J
U775CP6010, U775CP4010
(2) 14-50R, BR32U, 5-20R2GFCI
Fig. B
U075CP6010, U075CP4010
BR54U, BR32U, 5-20R2GFCI
Fig. C
U075CP6010D
BR54U, BR32U, 5-20R2GFCI
Fig. D
U075GP6, U075GP4
BR54U, BR32U, 5-20R2
Fig. E
U075GP6019
BR54U, BR32U, 5-20R2
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
A U611CP6010 U611CP4010 (2) BR32U,
5-20R2GFCI
(2) CB130,
CB120 80 T2 9PT
N
LC33N1 47
1
Y
B U075CP6010 2 U075CP4010 2,3 BR54U, BR32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 T2 9PT LC55N1 47
Y1
C U075CP6010D 4 — BR54U, BR32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 T2 9PT LC55N1 47
D U075GP6 U075GP4 BR54U, BR32U,
5-20R2
CB250, CB130,
GFI120 100 T2 9PT LC55N1 47
E U075GP6019 — BR54U, BR32U,
5-20R2
CB250, GFI130,
GFI120 100 T2 9PT LC55N1 47
F U131CP6010 — (2) BR32U,
(2) 5-20R2GFCI
(2) CB130, (2) CB120,
Space CB120 100 T2 14PT LC55N1 47
G U175CP6HP010 — BR54U, BR32U,
5-20R2GFCI
CB2100 Main, CB250,
CB130, CB120 100 W 14PT 198B8627G14 89
H U355GP6 — BR54U,
5-20R2
CB250, GFI120,
(2) Space 100A Max 100 T2 9PT LC55N1 47
I U004CP6010 U004CP40102 (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 T2 9PT LC55N1 47
J U775CP6010 U775CP4010 (2) 14-50R, BR32U,
5-20R2GFCI
(2) CB250T, CB130,
CB120T 125 T2 9PT 265A6250G34 97
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”.
See page 88-89 for TV/Telephone model diagrams.
3 Available in bronze paint – add “ZI” after model number.
4 Post depth dimension is non-standard (4-3/8").
* Wire Range Table on page 91.
POST
30 30 20
GFI
POST
SPACE
20
GFI GFI
30 30 20
POST
SPACE
50 30
GFI
20
POST
30 30 50
GFI
SPACE
SPACE
100
Main
POST
SPACE
50 30
GFI
20
POST
SPACE
SPACE
50 20
GFI
POST
SPACE
50 30 20
GFI
POST
50 20 50
GFI
POST
SPACE
50 30
GFI
20
GFI
POST
30 20 50 50
GFI
Midwest Electric Products
RV Equipment – Metallic
75
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, Earth Burial, 125 Amps, 120/208V
Fig. A
5S3S2S2SES
BR54U, BR32U, (2) 5-20R2GFCI
Fig. C
5S3S2S2SEB
BR54U, BR32U, (2) 5-20R2GFCI
Fig. D
5S3S3S2SEB
BR54U, (2) BR32U, 5-20R2GFCI
Fig. B
5S3S3S2SES
BR54U, (2) BR32U, 5-20R2GFCI
3-Phase
Fig. Model Number Receptacles Circuit Protection Sides Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A 5S3S2S2SES BR54U, BR32U,
(2) 5-20R2GFCI
CB250, GFI130,
(2) CB120
1 125 6-350
kcmil2 14PT N 3-Phase,
4 Wire — 1 Y1
B 5S3S3S2SES BR54U, (2) BR32U,
5-20R2GFCI
CB250, (2) GFI130,
CB120
3-Phase, Back-to-Back
Fig. Model Number Receptacles Circuit Protection Sides Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
C 5S3S2S2SEB BR54U, BR32U,
(2) 5-20R2GFCI
CB250, GFI130,
(2) CB120
2 125 6-350
kcmil2 14PT N 3-Phase,
4 Wire — 1 Y1
D 5S3S3S2SEB BR54U, (2) BR32U,
5-20R2GFCI
CB250, (2) GFI130,
CB120
1 cULus approved.
2 Loop Lugs – Line/Neutral/Ground.
* Wire Range Table on page 91.
POST
30 50
GFI
20 20
GFI GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
POST
30 50
GFI
20 30
GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
POST
30 50
GFI
20 20
GFI GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
20 20 30 50
GFI GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
POST
30 50
GFI
20 30
GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
30 50
GFI
20 30
GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
Midwest Electric Products
RV Equipment – Metallic
76
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, Back-to-Back, 30 Amps, 120V
Fig. A
U042GB
R32U, 5-20R2
Fig. B
U011GB6, U011GB4
(2) 5-20R2
Fig. C
U041CB6010, U041CB4010
R32U, 5-20R2GFCI
Fig. D
U041GB6, U041GB4
R32U, 5-20R2
Fig. E
U055GB6
BR54U, 5-20R2
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
B U011GB6 U011GB4 (2) 5-20R2 (2) GFI120,
Space CB120
70 T2 6PT N LC33N7 47 1 Y1
C U041CB6010 U041CB4010 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120
D U041GB6 U041GB4 R32U,
5-20R2
CB130, GFI120,
Space CB120
E U055GB6 — BR54U,
5-20R2
CB250,
GFI120
1 cULus approved.
* Wire Range Table on page 91.
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
A U042GB6 — R32U,
5-20R2
GFI130 Main,
(2) CB120 30 T2 6PT N LC33N7 47 1 Y1
* Wire Range Table on page 91.
Pedestal, Back-to-Back, 70 Amps, 120/240V
30
GFI
Main
30 20
POST
30
GFI
Main
30 20
POST
20
GFI
SPACE
20
GFI
20
GFI
SPACE
20
GFI
POST
30
SPACE
20
GFI
30
SPACE
20
GFI
POST
30
SPACE
20
GFI
30
SPACE
20
GFI
POST
50 20
GFI
50 20
GFI
Midwest Electric Products
RV Equipment – Metallic
77
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Pedestal, Back-to-Back, 80 – 120 Amps, 120/240V
Fig. A
U611CB6010, U611CB4010
(2) R32U, 5-20R2GFCI
Fig. B
U075CB6010, U075CB4010
BR54U, R32U, 5-20R2GFCI
Fig. C
U075GB6
BR54U, R32U, 5-20R2
Fig. D
U004CB6010, U004CB4010
(2) BR54U, 5-20R2GFCI
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Earth Burial Pad Mount
A U611CB6010 U611CB4010 (2) R32U,
5-20R2GFCI
(2) CB130,
CB120 80 T2 9PT
N
LC33N1
62 1 Y1
B U075CB60102 U075CB40102 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 S 9PT LC55N1
C U075GB6 — BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 S 9PT LC55N1
D U004CB6010 U004CB4010 (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 S 9PT LC55N1
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
POST
30 30 20
GFI
30 30 20
GFI
POST
SPACE
50 30 20
SPACE
50 30 20
GFI GFI
POST
SPACE
50 30 20
GFI
SPACE
50 30 20
GFI
POST
50 20 50 50 20 50
GFI GFI
Midwest Electric Products
RV Equipment – Metallic
78
Data subject to change without notice.
RV Equip – Metallic
Metered
Pedestal, Earth Burial, 70 – 100 Amps, 120/240V
Fig. A
M055GP6
BR54U, 5-20R2
Fig. E
M075GP6, R075GP6
BR54U, R32U, 5-20R2
Fig. B
M041CP6010, R041CP6010
R32U, 5-20R2GFCI
Fig. F
M355CP6010, R355CP6010
BR54U, 5-20R2GFCI
Fig. C
M041GP6, R041GP6
R32U, 5-20R2
Fig. G
M355GP6, R355GP6
BR54U, 5-20R2
Fig. D
M075CP6010, R075CP6010
BR54U, R32U, 5-20R2GFCI
Fig. H
M358CP6
BR54U, R32U
POST
30 20
GFI
SPACE
POST
20 50
SPACE
SPACE
GFI
POST
SPACE
50 30
GFI
20
POST
50 30
POST
50 20
GFI
POST
SPACE
50 30 20
GFI
POST
30 20
GFI
SPACE
POST
20 50
GFI
SPACE
SPACE
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M055GP6 — BR54U,
5-20R2
CB250,
GFI120 70
T2 9PT
N LC33N1 59
1 Y1
B M041CP6010 R041CP6010 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100 N LC33N1 53
C M041GP6 R041GP6 R32U,
5-20R2
CB130, GFI120,
Space CB120 100 N LC33N1 59
D M075CP60102 R075CP60102 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 N LC55N1 59
E M075GP6 R075GP6 BR54U,R32U,
5-20R2
GFI120,
Space CB120 100 N LC55N1 59
F M355CP6010 R355CP60102 BR54U,
5-20R2GFCI
CB250, CB120,
(2) Space CB120 100 Y LC55N1 59
G M355GP6 R355GP6 BR54U,
5-20R2
CB250, GFI120,
(2) Space CB120 100 N LC55N1 59
H M358CP6 — BR54U,
R32U
CB250,
CB130 100 N LC55N1 53
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
79
Data subject to change without notice.
RV Equip – Metallic
Metered
Pedestal, Earth Burial, 120 – 200 Amps, 120/240V
Fig. A
M004CP6010
(2) BR54U, 5-20R2GFCI
Fig. D
M655GP6
BR54U, 5-20R2
Fig. C
M275CP6010
BR54U, BR32U, 5-20R2GFCI
Fig. B
M775CP6010
(2) BR54U, BR32U, 5-20R2GFCI
Fig. E
M675CP6010
BR54U, BR32U, 5-20R2GFCI
Fig. F
R255CP6010
BR54U, 5-20R2GFCI
POST
30 20 50 50
GFI
POST
50 20 30 GFI
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
50 20 50
GFI
POST
POST
20 50
GFI
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
POST
50 30 20
GFI
SPACE
SPACE
SPACE
200 MAIN
SPACE
GFI
SPACE
200
MAIN
SPACE
SPACE
SPACE SPACE
LOAD
20 50
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M004CP6010 — (2) BR54U,
5-20R2GFCI
(2) CB250,
CB120 120 T2 9PT N LC55N1 48
1
Y1
B M775CP6010 — (2) BR54U, BR32U,
5-20R2GFCI
(2) CB250T, CB130,
CB120T 125 T2 9PT N — 59
C M275CP60102 — BR54U, BR32U,
5-20R2GFCI
CB2200B Main,
CB250, CB130, CB120 200 BX 14PT N LC1212PC 89
D M655GP6 — BR54U,
5-20R2
CB250, GFI120, Space
CB2200B, Space (5)
CB120 200A Max
200 T2 14PT N LC1212PC 85
E M675CP6010 — BR54U, BR32U,
5-20R2GFCI
CB250, CB130,
CB120 200 BY 14PT N LC1212PC 87
F — R255CP6010 BR54U,
5-20R2GFCI
CB2200B, CB250,
CB120 200 S 14PT Y LC1212PC 88 N
1 cULus approved.
2 Available in green paint – order as M275CP6010G1.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
80
Data subject to change without notice.
RV Equip – Metallic
Metered
Pedestal, Earth Burial, Back-to-Back, 100 – 200 Amps, 120/240V
Fig. A
M041CB6010
R32U, 5-20R2GFCI
Fig. E
M355GB6
BR54U, 5-20R2
Fig. B
M041GB6, R041GB6
R32U, 5-20R2
Fig. F
M775CB6010
(2) BR54U, BR32U, 5-20R2GFCI
Fig. C
M075CB6010, R075CB6010
BR54U, R32U, 5-20R2GFCI
Fig. G
M655GB6
BR54U, 5-20R2
Fig. D
M075GB6, R075GB6
BR54U, R32U, 5-20R2
Fig. H
R255CB6010
BR54U, 5-20R2GFCI
POST
30 20
GFI
SPACE
30 20
GFI
SPACE
POST
50 20
GFI
SPACE
SPACE
50 20
GFI
SPACE
SPACE
POST
30 20
GFI
SPACE
30 20
GFI
SPACE
POST
30 20 50 50
GFI
30 20 50 50
GFI
POST
20 50
GFI
SPACE
SPACE
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
20 50
GFI
SPACE
SPACE
SPACE
SPACE SPACE
SPACE
SPACE
SPACE
SPACE
POST
SPACE
50 30
GFI
20
SPACE
50 30
GFI
20
POST
SPACE
50 30 20
GFI
SPACE
50 30 20
GFI
GFI
SPACE
200
MAIN
SPACE
SPACE
SPACE SPACE
LOAD
20 50
GFI
SPACE
200
MAIN
SPACE
SPACE
SPACE SPACE
LOAD
20 50
POST
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M041CB6010 — R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 100
S
9PT N LC33N1 82
1
Y1
B M041GB6 R041GB6 R32U,
5-20R2
CB130, GFI120,
Space CB120 100 9PT N LC33N1 82
C M075CB60102 R075CB6010 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 9PT N LC55N1 82
D M075GB6 R075GB6 BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 9PT N LC55N1 82
E M355GB6 — BR54U,
5-20R2
CB250, GFI120,
(2) Space CB2100 100 9PT N LC55N1 82
F M775CB6010 — (2) BR54U, BR32U,
5-20R2GFCI
(2) CB250T,
CB130, CB120T 125 9PT N — 82
G M655GB6 — BR54U,
5-20R2
CB250, GFI120,
(9) Space CB120 200 14PT N LC12122PC,
N1200A4 80
H — R255CB6010 BR54U,
5-20R2GFCI
CB2200B,
CB250, CB120 200 14PT Y LC12122PC 101 N
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
81
Data subject to change without notice.
RV Equip – Metallic
Metered
Pedestal, Pad Mount, 100 Amps, 120/240V
Fig. B
M041GP4
R32U, 5-20R2
Fig. D
M075GP4
BR54U, R32U, 5-20R2
Fig. A
M041CP4010
R32U, 5-20R2GFCI
Fig. F
M075CB4010
BR54U, R32U, 5-20R2GFCI
Fig. C
M075CP4010, R075CP4010
BR54U, R32U, 5-20R2GFCI
Fig. E
M355GP4
BR54U, 5-20R2
POST
SPACE
50 30
GFI
20
SPACE
50 30
GFI
20
POST
SPACE
50 30
GFI
20
POST
20 50
GFI
SPACE
SPACE POST
30 20
GFI
SPACE
POST
SPACE
50 30 20
GFI
POST
30 20
GFI
SPACE
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A M041CP4010 — R32U,
5-20R2GFCI
CB130, CB120,
Space CB120
100 T2 9PT N
LC33N1 53
1 Y1
B M041GP4 — R32U,
5-20R2
CB130, GFI120,
Space CB120 LC33N1 59
C M075CP4010 R075CP4010 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 LC55N1 59
D M075GP4 — BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 LC55N1 59
E M355GP4 — BR54U,
5-20R2
CB250, GFI120,
Space CB2100 LC55N1 59
Back-to-Back
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
F M075CB4010 — BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 100 S 9PT N LC55N1 82 1 Y1
1 cULus approved.
* Wire Range Table on page 91.
Midwest Electric Products
RV Equipment – Metallic
82
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Lighted, Surface 100 Amps, 120/240V
Metered
Lighted, Pedestal, 100 Amps, 120/240V
Fig. D
M075CP6L10, M075CP4L10
BR54U, R32U, 5-20R2GFCI
Fig. B
U075CTLL10
BR32U, R32U, 5-20R2
Fig. C
M041CP6L10, M041CP4L10
R32U, 5-20R2GFCI
Fig. A
U041CTLL10
R32U, 5-20R2GFCI
POST
SPACE
50 30
GFI
20
GFI
50 30
SPACE
20
GFI
POST
30 20
SPACE
GFI
SPACE
30 20
GFI
Fig. Model Number Receptacles Circuit Protection Amps Lug Type
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
A U041CTLL10 R32U,
5-20R2GFCI
CB130,
CB120
100 Loop Feed W 9 x 17 N
LC33N1T 14
1 Y1
B U075CTLL10 BR32U, R32U
5-20R2GFCI
CB250, CB130,
Space CB120 LC55N1T 16
1 cULus approved.
* Wire Range Table on page 91.
Light Socket Assembly.
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
C M041CP6L10 M041CP4L102 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120
100 T2 9PT Y
LC33N1 50
1 Y1
D M075CP6L102,3 M075CP4L102 BR54U, R32U,
5-20R2GFCI
CB250, CB130,
CB120, Space CB120 LC55N1 59
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
3 Available with 350 MCM loop lugs – replace “010” with “039”.
* Wire Range Table on page 91.
Light Socket Assembly.
Midwest Electric Products
RV Equipment – Metallic
83
Data subject to change without notice.
RV Equip – Metallic
Unmetered
Lighted, Pedestal, 70 – 100 Amps, 120/240V
Fig. B
U041CP6L10, U041CP6L10
R32U, 5-20R2GFCI
Fig. D
U075CB6L10, U075CB4L10
BR54U, R32U, 5-20R2GFCI
Fig. A
U041CB6L10, U041CB4L10
R32U, 5-20R2GFC
Fig. C
U041GP6L, U041GP4L
BR54U, R32U, 5-20R2
Fig. E
U075CP6L10, U075GP4L
BR54U, R32U, 5-20R2GFCI
POST
30
SPACE
20
GFI
30
SPACE
20
GFI
POST
SPACE
50 30
GFI
20
SPACE
50 30
GFI
20
POST
30
SPACE
20
GFI
POST
SPACE
50 30
GFI
20
POST
30
SPACE
20
GFI
POST
SPACE
50 30 20
GFI
Fig.
Model Number
Receptacles Circuit Protection Amps
Wire
Range*
Cabinet
Size
Hub
Opening
Load &
Neutral Bar
Unit
Wt.
Std
Pkg.
UL
Ring Type Ringless
A U041CB6L10 U041CB4L10 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 70 T2 6PT
N
LC33N1 42
1 Y1
B U041CP6L10 U041CP4L10 R32U,
5-20R2GFCI
CB130, CB120,
Space CB120 70 T2 6PT LC33N1 30
C U041GP6L U041GP4L BR54U, R32U,
5-20R2
CB130, GFI120, Space
CB120, CB250, CB130 70 T2 6PT LC33N1 30
D U075CB6L10 U075CB4L10 BR54U, R32U,
5-20R2GFCI
CB120, Space CB120,
CB250, CB130 100 S 9PT LC55N1 62
E U075CP6L102 U075CP4L102 BR54U, R32U,
5-20R2GFCI
CB120,
Space CB120 100 T2 9PT LC55N1 36
F U075GP6L U075GP4L BR54U, R32U,
5-20R2
CB250, CB130,
GFI120, Space CB120 100 T2 9PT LC55N1 62
1 cULus approved.
2 Available with factory installed TV/Telephone – replace “010” with “031”. See page 88-89 for TV/Telephone model diagrams.
* Wire Range Table on page 91.
Light Socket Assembly.
Fig. F
UO75GP6L
BR54U, R32U, 5-20R2
Midwest Electric Products
RV Equipment – Metallic
84
Data subject to change without notice.
RV Equip – Metallic
Technical Data
Model Number
Replacement Parts
Cabinet Size
Enclosure
Style1
Cabinet Dimensions (inches)3 Knockout
Meter Socket Post Lugs Height (A) Width (B) Depth (C) Figure2
5S3S2S2SEB — LT100B350 14PT — — —
5S3S2S2SES — LT100S250 14PT — — —
5S3S3S2SEB — LT100B350 14PT — — —
5S3S3S2SES — LT100S250 14PT — — —
M004C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M004CP6010 MSM100P9 LT100S300 9PT — — —
M031C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M041C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M041CB6010 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M041CP4010 MSM100P9 LT100S300 9PT — — —
M041CP4L10 MSM100P9 LT100S250 9PT — — —
M041CP4L31 MSM100P9 LT100S300 9PT — — —
M041CP6010 MSM100P9 LT100S300 9PT — — —
M041CP6L10 MSM100P9 LT100S250 9PT — — —
M041G MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M041GB6 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M041GP4 MSM100P9 LT100S250 9PT — — —
M041GP6 MSM100P9 LT100S300 9PT — — —
M055C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M055G MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M055GP6 MSM100P9 LT100S250 9PT — — —
M075C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M075CB4010 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M075CB6010 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M075CB6031 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M075CP4010 MSM100P9 LT100S300 9PT — — —
M075CP4L10 MSM100P9 LT100S300 9PT — — —
M075CP4L31 MSM100P9 LT100S300 9PT — — —
M075CP6010 MSM100P9 LT100S300 9PT — — —
M075CP6031 MSM100P9 LT100S300 9PT — — —
M075CP6L10 MSM100P9 LT100S300 9PT — — —
M075CP6L31 MSM100P9 LT100S300 9PT — — —
M075CP6L39 MSM100P9 LT100S350 9PT — — —
M075G MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M075GB6 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M075GP4 MSM100P9 LT100S250 9PT — — —
M075GP6 MSM100P9 LT100S250 9PT — — —
M076C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M275CP6010 —6 LT200S350 14PT — — —
M355C010 MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M355CP6010 MSM100P9 LT100S300 9PT — — —
M355G MSM100930 — 9 x 30 B 30 9-3/4 5-3/16 2
M355GB6 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M355GP4 MSM100P9 LT100S300 9PT — — —
M355GP6 MSM100P9 LT100S300 9PT — — —
M358CP6 MSM100P9 LT100B350 9PT — — —
M655GB6 MW200M LT200B350 14PT — — —
M655GP6 MW200M LT200S350 14PT — — —
M675CP6010/G1 —6 LT200S350 14PT — — —
M775CB6010 MSM100P9, MSM100HP4 LT100B350 9PT A — —
M775CP6010 MSM100P9 LT100S250 9PT — — —
R031C010 MSR100930 — 9 x 30 B 30 9-3/4 5-3/16 2
R041C010 MSR100930 — 9 x 30 B 30 9-3/4 5-3/16 2
R041CP6010 MSR100P9 LT100S300 9PT — — —
R041G MSR100930 — 9 x 30 B 30 9-3/4 5-3/16 2
R041GB6 MSR100P9, MSR100HP5 LT100B350 9PT B — —
R041GP6 MSR100P9 LT100S250 9PT — — —
1 Enclosure Styles on page 87.
2 Knockout Figures on page 87.
展开
必填*
-
姓名:
-
联系手机:
-
需求量:
选填
-
固话电话:
-
联系邮箱:
-
所在单位:
所咨询的内容:
我想了解:《SOUTHERN AVIONICS 供应SAC4343》的详细信息.请商家尽快与我联系。