REF-20-S不锈钢法兰减压阀台湾日泰Z-TIDE阀门 特价活动
上海达琼流体科技有限公司专业销售Z-TIDE产品,源头供应台湾Z-TIDE(日泰)产品备件,价格优惠,现货供应,品质保证,采购首选
品牌介绍:
台湾日泰(Z-Tide)为台湾专业水用阀门生产商,产品可应用于给水、空调、消防系统等。产品获ISO9001认证。其产品材质范围广,主要有:铸铁、球墨铸铁、铇青铜、不锈钢等。
生产的产品主要包括:减压阀(直动式、先导式)、持压阀、泄压阀、定水位阀(浮球阀)、电磁阀、减压阀组、静音止回阀、水锤吸收器(隔膜式、弯头式、直型、T型、角式等)。
上海达琼流体科技有限公司为台湾Z-Tide阀门在大陆地区的总代理,负责其产品在大陆地区的销售、售后服务、技术支持等工作。
电话: 021-51870570
手机:15201798507
QQ:1984404050
地址:上海市奉贤区五四公路4399号
REF-20-S不锈钢法兰减压阀台湾日泰Z-TIDE阀门 特价活动
|
Model:REF(Flange Type)、RET(Thread Type)
|
|
|
|
|
Product accent:
|
-
Valve Body is made by Stainless Steel #316, suitable for fluid, air and vapor.
-
The gate is balanced-pressure designed, which will not influence the outlet pressure caused by unstable inlet pressure.
-
When the outlet pressure responds directly to the pressure control chamber and adjusts the setting pressure, it responds quickly and adjusts the pressure accurately.
-
Design of piston and diaphragm improves the inability of sustaining pressure and leakage.
-
Pressure Adjusting Range:
(1 kgf/cm2 = 14.2 psi)
1kgf / cm2~6kgf / cm2
4kgf / cm2~10kgf / cm2
8kgf / cm2~13kgf / cm2
-
Applied Temperature:
-15℃~80℃
-
Valve Body Testing Pressure :35 kgf/cm2
-
Please cover steam pipelines with thermal materials
-
Special order can be arranged for higher pressure adjustment range
|
|
|
|
|
Thread Type-illustration
|
|
-
Pressure Gauge
-
Upper Cover:Stainless Steel 316
-
U-ring:NBR / Viton
-
Piston:Stainless Steel 316
-
Sealing Spacer:NBR / Viton/Teflon
-
Shaft:Stainless Steel 316
-
Main Body:Stainless Steel 316
-
Diaphragm:NBR / Viton
-
HU-ring:NBR / Viton
-
Spring:Spring Steel
-
Lower Cover:Stainless Steel 316
-
Washer :Brass
-
Adjusting Stem:Stainless Steeel 304
|
|
|
Item No
|
Thread Type
|
H
|
L
|
CV
|
RET-15S
|
1/2"
|
75
|
71
|
2.5
|
RET-20S
|
3/4"
|
75
|
86
|
4.0
|
RET-25S
|
1"
|
81
|
90
|
6.5
|
RET-40S
|
1 1/2"
|
115
|
115
|
13.0
|
RET-50S
|
2"
|
115
|
120
|
17.0
|
尺寸單位:mm
|
|
Flange Type-illustration
|
|
-
Pressure Gauge
-
Upper Cover:Stainless Steel
-
O-ring:NBR / Viton
-
U-ring:NBR / Viton
-
Piston:Stainless Steel 316
-
Sealing Spacer:NBR / Viton
-
Shaft:Stainless Steel 316
-
Diaphragm:NBR / Viton
-
Main Body:Stainless Steel 316
-
UH-ring:NBR / VIiton
-
Fixed Bolt:Stainless Steel 304
-
Spring:Spring Steel
-
Lower Cover:Stainless Steel 316
-
Washer:Brass
-
Adjusting Stem:Stainless Steel 304
|
|
|
Item No
|
Flange Type
|
H
|
L
|
CV
|
REF-15-S
|
1/2"
|
75
|
150
|
2.5
|
REF-20-S
|
3/4"
|
82
|
150
|
4.0
|
REF-25-S
|
1"
|
82
|
150
|
6.5
|
REF-40-S
|
1 1/2"
|
115
|
190
|
13.0
|
REF-50-S
|
2"
|
115
|
192
|
17.0
|
REF-65-S
|
2 1/2"
|
185
|
210
|
30.0
|
REF-80-S
|
3"
|
185
|
225
|
42.0
|
REF-100-S
|
4"
|
230
|
250
|
75.0
|
REF-150-S
|
6"
|
290
|
310
|
170.0
|
尺寸單位:mm
|
|
Applied Condition of Direct-activated Pressure Reducing Valve
|
|
-
Installing pressure reducing valve directly in the sub-pipe can reduce fluid pressure inside the pipe.
-
Installing a filter in the inlet of pressure reducing valve can prevent block of valve gate caused by impurities and limescale.
-
Installing pressure relief valve downstream pressure reducing valve can protect the system.
-
While using screws to connect pressure reducing valve, joints should be installed in the inlet and outlet to make maintenance easy.
|
|
Pressure Setting and Flow Rate of Direct-activated Pressure Reducing Valve
|
Direct-activated pressure reducing valve directly opens and closes the valve gate by the outlet pressure. When outlet pressure is under setting pressure, valve gate automatically opens. To make valve gate fully open, adjustable pressure range and setting pressure are relative points.
A: Pressure drop needed for fully-opened valve gate = , B=Adjustable Pressure Range Maximum – Minimum
B:Adjustable Pressure Range (=Maximum Minimum Adjustable Pressure Range)
C:Setting Pressure of Outlet
D:Pressure of fully-opened outlet valve gate, P=C-A
Example:
Pressure drop needed for fully-opened valve gate for adjusting pressure range 3~9 kgf/cm2 of direct-activated pressure reducing valve.
If the setting pressure of outlet is 6kgf / cm2, pressure of fully-opened valve gate will be P=6-1.5=4.5 kgf/ cm2(Outlet pressure should go down under 4.5kgf/ cm2 to make valve gate fully open)
|
|
Flow Chart of Direct-activated Pressure Reducing Valve
|
|