返回 供应详情
HA44e/475-4  HA4/465-4
HA44e/475-4 HA4/465-4
来自:福州天行健节能科技有限公司
12000人民币
发布时间:2021-11-9 关注次数:1512
产品参数
产品参数
品牌 德国GEA-Bock
规格型号 HA44e/475-4 HA4/465-4
编号 HA44e/475-4 HA4/465-4
计量单位
付款方式 先付部分货款
价格单位 人民币
商品详情

HA44e/475-4  HA4/465-4

福州天行健provide原厂GEA-Bock船用压缩机及压缩机零部件

福州天行健节能科技有限公司提供欧美日船舶原装进口品牌零部件



HA single-stage compressors
The HA-system - the best solution for deep-freezing!

Special features:
- Direct intake with external ventilation
- Suction gas intake directly into the compressor
- Motor cooled by an integrated ventilation unit

This reduces the compressed gas temperature and thus expands the range of application while at the same time increasing capacity (deep-freeze, R22, R404A). At the same time, the compressor is physically separated from the compressor, with advantages particularly in the case of motor damage.

Technical data

HAX44e/475-4

Application Refrigeration & AC

Compressor refrigeration capacity 7.43 kW

Power consumption 4.62 kW

Current draw (400 V) 12.30 A

Mass flow 0.056 kg/s

at following operating condition:

Refrigerant R404A, R507

Reference temperature Dew point

Evaporating temperature -35.0 °C

Condensing temperature 40.0 °C

Supply frequency 50 Hz

Voltage 400 V

Suction gas temperature 20 °C

Subcooling (outside cond.) 0 K

Number of cylinders / Bore / Stroke 4 / 55 mm / 50 mm

Displacement 50/60 Hz (1450/1740 ¹/min) 41,30 / 49,60 m³/h

Voltage 1) 380-420V Y/YY -3- 50Hz PW

440-480V Y/YY -3- 60Hz PW

Winding divided into 50% / 50%

Max. working current 2) 15.2 A

Max. power consumption 2) 7.6 kW

Starting current (rotor blocked) 2) 87.0 / 149.0 A

Motor protection INT69 G

Protection terminal box / HA-fan IP 66 / IP 44

Voltage HA-fan 230 V - 1 - 50/60 Hz, 140 W

Protection terminal box IP 66

Weight 174 kg

Max. permissible overpressure (g) (LP/HP) 3) 19 / 28 bar

Connection suction line SV 35 mm - 1 3/8 "

Connection discharge line DV 28 mm - 1 1/8 "

Lubrication Oil pump

Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A BOCKlub E55

Oil type R22 BOCKlub A46

Oil charge 2,7 Ltr.

Oil sump heater 230 V - 1 - 50/60 Hz, 160 W

Dimensions Length / Width / Height 717 / 361 / 408 mm

Sound power level LWA 4) 81 db(A) @ -35 °C / +40 °C

Sound pressure level LpA 4) 68 dB(A) @ -35 °C / +40 °C

Scope of supply

Semi-hermetic four-cylinder reciprocating compressor with drive motor for part winding start

380-420 V Y/YY - 3 - 50 Hz

440-480 V Y/YY - 3 - 60 Hz

Single-section compressor housing with hermetically integrated electric motor

Oil pump

Motor is cooled by an integrated ventilator with air deflection hood.

230 V - 1 - 50/60 Hz, IP44, 140 W, 0,71 A

Winding protection with PTC resistor sensors and electronic trigger unit INT69 G

115-230 V AC, 50/60 Hz, IP00

Rear bearing flange prepared for oil differential pressure sensor DELTA-P II

Possibility of connection of oil level controllers ESK, AC+R or CARLY

Possibility of connection of oil level controllers Traxoil 5)

Possibility for connection of oil pressure safety switch MP54

Oil charge:

HA: BOCKlub A46

HAX: BOCKlub E55

Sight glass

Pressure relief valve

Suction and discharge line valve

Inert gas charge

4 anti-vibration pads enclosed

Accessories

Start unloader by means of a ESS (Electronic Soft Start), 400 V - 3 - 50/60 Hz, IP20 (Connection clamps IP00) for installation in switch cabinet 6)

Digital capacity regulator DCR14 230 V - 1 - 50/60 Hz, IP65

1 digital capacity regulator = 50% residual capacity 7)

Cylinder cover prepared for digital capacity regulator

Oil sump heater

230 V - 1 - 50/60 Hz, 160 W, IP66

PTC heater self-regulating

Thermal protection thermostat per cylinder cover 7)

Oil pressure safety switch MP54 230 V - 1 - 50/60 Hz, IP20 6)

Oil differential pressure sensor DELTA-P II 220-240 V - 1 - 50/60 Hz 8)

Connection piece suction and discharge valve in welding design 9)

USB converter for INT69 G Diagnose 6)

Oil temperature sensor (Pt1000, for external evaluation) 7)

INT69 G Diagnose 115-230 V AC, 50/60 Hz, IP00 (INT69 G not applicable)

DP-Modbus Gateway 115-230 V AC, 50/60 Hz, IP00 including adapter cable 6)

Modbus-LAN Gateway 230 V AC, 50/60 Hz, IP00 6)

Intermediate flange for suction valve on right seen from oil pump in conjunction with capacity regulator 6)

Step protection

Special voltage and/or frequency (on request)

Notes

1) Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request

All data are based on voltage rms values

PW = part winding, motors for part winding starting

(no start unloaders required)

Designs for Y/D on request

2) - The stated value for the max. power consumption is valid for the adjusted power supply.

- Starting current (rotor blocked):

Part winding (PW) motors: Winding 1 / Winding 1+2

Delta/Star (Δ/Y) motors: Δ / Y

- Take account of the max. operating current / max. power consumption for designing fuses, supply lines and safety devices. Fuse: Consumption category AC3.

3) LP = Low pressure

HP = High pressure

4) Declared dual-number noise emission values are in accordance with ISO 4871. The corresponding uncertainty to the sound power level is KWA = 2,5 dB and to the sound pressure level is KpA = 2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the standard rating points according to EN 12900.

A-weighted sound power level LWA (re 1 pW), in decibel. To determine the values, measurement methods of the ISO 3740 standard with accuracy class 2 or higher were used .

A-weighted sound pressure level LpA (re 20 µPa), in decibel. The values are calculated from the sound power level in accordance with ISO 11203: LpA = LWA - Q2 at a distance of d = 1m to the reference box.

5) Only with additional adapter possible

6) Enclosure

7) Mounted

8) Enclosure (screw-in part mounted)

9) On request


展开
福州天行健节能科技有限公司
VIP会员
袁佐俊(经理) 电话咨询 在线询盘
询盘信息
必填*
  • 姓名:
  • 联系手机:
  • 需求量:
选填
  • 固话电话:
  • 联系邮箱:
  • 所在单位:
所咨询的内容:

我想了解:《HA44e/475-4 HA4/465-4》的详细信息.请商家尽快与我联系。

完成
咨询内容
完成
0/100
完成