崇安区 6SL3040-0JA00-0AA0

概述
CU305 PN Control Unit
The CU305 Control Unit for the communication and open-loop/closed-loop control functions of a SINAMICS S110 is combined with the PM240‑2 Power Module in blocksize format (usable as of firmware V4.4 SP3) to create a powerful single drive.

设计
The CU305 Control Unit features the following connections and interfaces as standard:
-
Fieldbus interface
- CU305 PN: 1 PROFINET interface with 2 ports (RJ45 sockets) with PROFIdrive V4 profile
- CU305 DP: 1 PROFIBUS interface with PROFIdrive V4 profile
- 1 DRIVE-CLiQ socket, used solely to connect a DRIVE-CLiQ motor or a Sensor Module
-
1 onboard encoder evaluation for evaluating the following encoder signals
- Incremental encoder TTL/HTL
- SSI encoder without incremental signals
- 1 PE/protective conductor connection
- 1 connection for the electronics power supply via the 24 V DC power supply connector
- 1 temperature sensor input (KTY84‑130 or PTC)
- 3 parameterizable, fail-safe digital inputs (isolated), or alternatively 6 parameterizable digital inputs (isolated)
- 5 parameterizable digital inputs (isolated)
- 1 parameterizable, fail-safe digital output (isolated), or alternatively 1 digital output (isolated)
- 4 parameterizable bidirectional digital inputs/outputs
- 1 analog input ± 10 V, resolution 12 bit + sign
- 1 serial RS232 interface
- 1 slot for the memory card on which the firmware, parameters and licenses can be stored
- 1 PM-IF interface for communication with the PM240‑2 Power Modules in blocksize format (usable as of firmware V4.4 SP3)
- 2 test sockets and one reference ground for commissioning support
- 1 interface to the BOP20 Basic Operator Panel

集成
The CU305 Control Unit controls the PM240 2 Power Module in blocksize format (usable as of firmware V4.4 SP3) via the PM-IF interface.
A BOP20 Basic Operator Panel can also be snapped directly onto the CU305 for diagnostic purposes.
DRIVE-CLiQ motors can be connected to the integrated DRIVE-CLiQ socket as well as Sensor Modules (SMC) to permit the operation of motors without a DRIVE-CLiQ interface.
The status of the CU305 is indicated via multi-color LEDs.
The CU305 can be operated optionally with memory card. The firmware and project data are stored on the memory card pluggable from below, so that the CU305 can be replaced without the support of software tools. This memory card can also be used to perform standard commissioning on multiple drives of identical type. The card is available as an empty memory card or containing the latest drive firmware version. The card also contains the safety license for the Extended Safety Functions. To use these Extended Safety Functions, a memory card containing the safety license must be permanently inserted.
The CU305 and other connected components are commissioned and diagnosed with the STARTER commissioning tool.
Connection example of CU305 Control Unit

技术规范
CU305 PN / CU305 DP Control Units PROFINET: 6SL3040-0JA01-0AA0 PROFIBUS: 6SL3040-0JA00-0AA0 |
|
---|---|
Current requirement
At 24 V DC, max. |
0.8 A for CU305 incl. 350 mA for HTL encoder + 0.5 A for PM240‑2 Power Module |
Conductor cross-section, max. |
2.5 mm2 |
Fuse protection, max. |
20 A |
Digital inputs |
in accordance with IEC 61131‑2 Type 1 3 isolated fail-safe inputs 5 isolated digital inputs |
|
-3 ... +30 V |
|
-3 ... +5 V |
|
15 ... 30 V |
|
6 mA |
|
|
|
15 μs |
|
55 μs |
|
|
|
5 μs |
|
5 μs |
|
1.5 mm2 |
Digital outputs (continuously short-circuit-proof) |
1 fail-safe digital output 4 bidirectional digital inputs/digital outputs, not isolated |
|
24 V DC |
|
100 mA |
|
150 μs |
|
1.5 mm2 |
Analog input |
-10 ... +10 V |
|
15 kΩ |
Encoder evaluation |
|
|
24 V DC/0.35 A or 5 V DC/0.35 A |
|
2 ... 10 mA (typ. 5 mA) |
|
500 kHz |
|
100 ... 250 kBaud |
|
30 bit |
|
|
|
100 m (328 ft) (only bipolar signals permitted) 3) |
|
100 m (328 ft) for unipolar signals 300 m (984 ft) for bipolar signals 3) |
|
100 m (328 ft) |
Power loss |
<20 W |
PE connection |
M5 screw |
Dimensions |
|
|
73 mm (2.87 in) |
|
|
|
195 mm (7.68 in) |
|
183.2 mm (7.21 in) |
|
|
|
71 mm (2.80 in) |
|
55 mm (2.17 in) |
Weight, approx. |
0.95 kg (2.09 lb) |
Certificate of suitability |
cULus |