西门子S120驱动模块6SL3120-2TE21-0AD0
在松江工业园区有一定的名声
不要问我有没有 西门子常规的都现货 支持上门提货
有需要的新老顾客欢迎上门提货谈生意(老顾客注意公司地址更改)
上海斌勤电气技术有限公司(西门子合作伙伴)
联系人 :康 奎(业务经理)发布(联系我有优惠福利哦)
地 址:上海市松江区三新北路1800弄(松江商务电子园区)24号楼5005室.
技术规范
|
Double Motor Module in booksize format 6SL3120-2TE... |
---|---|
DC link voltage (up to 2000 m (6562 ft) above sea level) |
510 ... 720 V DC |
Output frequency |
|
|
0 ... 650 Hz 1) 2) 3) |
|
0 ... 300 Hz 2) |
|
0 ... 600 Hz 2) 3) |
Electronics power supply |
24 V DC -15 %/+20 % |
Type of cooling |
Internal air cooling (power units with increased air cooling by built-in fan) |
Permissible ambient and coolant temperature (air) during operation for line-side components, Line Modules and Motor Modules |
0 ... 40 °C (32 ... 104 °F) without derating, |
Installation altitude |
Up to 1000 m (3281 ft) above sea level without derating, |
Declarations of conformity |
CE (Low-Voltage and EMC Directives) |
Certificate of suitability |
cULus |
Safety Integrated |
Safety Integrity Level 2 (SIL 2) according to IEC 61508, For further information, see section Safety Integrated. |
1) At rated output current (max. output frequency 1300 Hz for 62.5 µs current control cycle, 8 kHz pulse frequency, 60 % permissible output current).
2) Note the correlation between max. output frequency, pulse frequency and current derating. For further information, see section Configuration notes.
3) The output frequency is currently limited to 550 Hz. The specified values apply to systems with license for high output frequency. For further information, see section Control Units and https://support.industry.siemens.com/cs/document/104020669
DC link voltage 510 ... 720 V DC |
Double Motor Module in booksize format |
||||
---|---|---|---|---|---|
Internal air cooling C type |
6SL3120-... |
– |
– |
– |
2TE21-8AC0 |
Internal air cooling D type |
6SL3120-... |
2TE13-0AD0 |
2TE15-0AD0 |
2TE21-0AD0 |
2TE21-8AD0 |
Output current |
|
|
|
|
|
|
A |
2 × 3 |
2 × 5 |
2 × 9 |
2 × 18 |
|
|
|
|
|
|
|
A |
– |
– |
– |
2 × 24 |
|
A |
2 × 4 |
2 × 6.7 |
2 × 12 |
2 × 24 |
|
A |
2 × 2.6 |
2 × 4.3 |
2 × 7.7 |
2 × 15.3 |
|
|
|
|
|
|
|
A |
– |
– |
– |
2 × 36 |
|
A |
2 × 9 |
2 × 15 |
2 × 27 |
2 × 54 |
Type rating 1) |
|
|
|
|
|
|
kW (hp) |
2 × 1.6 (1.5) |
2 × 2.7 (3) |
2 × 4.8 (5) |
2 × 9.7 (10) |
|
kW (hp) |
2 × 1.4 (1) |
2 × 2.3 (2.5) |
2 × 4.1 (5) |
2 × 8.2 (10) |
DC link current Id2) |
A |
7.2 |
12 |
22 |
43 |
Current carrying capacity |
|
|
|
|
|
|
A |
100 |
100 |
100 |
100 |
|
A |
20 |
20 |
20 |
20 |
DC link capacitance |
μF |
220 |
220 |
220 |
705 |
Current requirement At 24 V DC, max. |
A |
0.9 |
0.9 |
0.9 |
1.1 |
Power loss 4) typ. 5)/max. |
kW |
0.05/0.1 |
0.08/0.13 |
0.15/0.19 |
0.28/0.35 |
Cooling air requirement |
m3/s (ft3/s) |
0.009 (0.32) |
0.009 (0.32) |
0.009 (0.32) |
0.0155 (0.55) |
Sound pressure level LpA (1 m) |
dB |
<60 |
<60 |
<60 |
<60 |
Motor connection U2, V2, W2 |
|
2 × plug-in connector (X1, X2) 6), |
2 × plug-in connector (X1, X2) 6), |
2 × plug-in connector (X1, X2) 6), |
2 × plug-in connector (X1, X2) 6), |
PE connection |
|
M5 screw |
M5 screw |
M5 screw |
M5 screw |
Motor brake connection |
|
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A |
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A |
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A |
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A |
Motor cable length, max. |
|
|
|
|
|
|
m (ft) |
50 (164) |
50 (164) |
50 (164) |
70 (230) |
|
m (ft) |
75 (246) |
75 (246) |
75 (246) |
100 (328) |
Degree of protection |
|
IP20 |
IP20 |
IP20 |
IP20 |
Dimensions |
|
|
|
|
|
|
mm (in) |
50 (1.97) |
50 (1.97) |
50 (1.97) |
100 (3.94) |
|
mm (in) |
380 (14.96) |
380 (14.96) |
380 (14.96) |
380 (14.96) |
|
mm (in) |
270 (10.63) |
270 (10.63) |
270 (10.63) |
270 (10.63) |
Weight, approx. |
kg (lb) |
4.7 (10.4) |
4.7 (10.4) |
4.7 (10.4) |
7.7 (17.0) |
1) Rated power of a typical standard asynchronous (induction) motor at 600 V DC link voltage.
2) Rated DC link current for dimensioning an external DC connection. For DC link current calculation for dimensioning the Line Module, see section Configuration notes.
3) If, due to a number of Line Modules and Motor Modules being mounted side-by-side, the current carrying capacity exceeds 20 A, an additional 24 V DC connection using a 24 V terminal adapter is required (max. cross-section 6 mm2, max. fuse protection 20 A).
4) Power loss of Motor Module at rated power including losses of 24 V DC electronics power supply.
5) At max. motor cable length 30 m (98.43 ft), pulse frequency 4 kHz and DC link voltage 540 ... 600 V.
6) Connector not included in scope of delivery, see Accessories.
-