0/100
代理经销CA7-9-01-120
来自:厦门纪扬科技有限公司
1人民币
发布时间:2017-7-26
关注次数:118
产品参数
商品详情
Industrial Circuit Breaker Accessories
15-150A Circuit Breakers.....................................................................1-8
70-250A Circuit Breakers.....................................................................1-9
125-600A Circuit Breakers ..................................................................1-9
300-1200A Circuit Breakers.............................................................1-10
Rating Plugs.............................................................................................1-11
Power Management System Accessories
For Spectra? RMS Circuit Breakers ...............................................1-12
Record Plus? FC 100 Accessories.......................................................1-17
Record Plus? FE 250 Accessories .......................................................1-18
Insulated Case Circuit Breakers
History/Timeline .........................................................................................1-19
Power Break? II Circuit Breaker Accessories
Enhanced MicoVersaTrip?, Rating Plug Selection .................1-20
Stationary & Draw-out Breaker Accessories ...........................1-21
Stationary Breaker Mounting Kits.................................................1-27
Neutral Current Sensors & POWER LEADER Accessories ..1-29
Draw-out Breakers and Accessories...........................................1-30
Disconnect Switches & Operating Mechanisms
High-Pressure Contact Switch
With Internal Ground Fault Devices.............................................1-32
Accessories..............................................................................................1-33
1
This catalog contains replacement parts, retrofits, accessories,
and older generation products. For current generation products,
please see the GE BuyLog? or Control Catalog.
Components: Parts
1
1-2 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Molded Case Circuit Breakers
History/Timeline
GE Molded Case Circuit Breakers History/Timeline
1950s CORE (Q-Line, TEY, THED, THFK, THJK, THKM)
Thermal Magnetic
1970s CORE (TJLS, TKLS, TJL4V, TKL4V)
Electronic Trip (VersaTrip, SelecTrip, RMS9, MVT)
1990s Spectra? SE, SF, SG, SK
Electronic Trip (S1, MVT+, MVTpm)
2005 Record Plus? (FB)
Thermal Magnetic
2007 Record Plus? (FE, FG)
Electronic Trip (SMR1, SMR2)
This catalog contains replacement parts, retrofits, accessories,
and older generation products. For current generation products,
please see the GE BuyLog? or Control Catalog.
Components: Parts
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-3
to change without notice
Auxiliary Switches
Unless otherwise noted switch is SPDT rated 6 amperes at rated ac voltage, 1/2 amperes at 125 Vdc, 1/4 amperes at 250 Vdc.
Control Voltage 240 Vac, 250 Vdc Maximum Control Voltage 600 Vac, 250 Vdc Maximum
UL Listed When Factory Installed Suffix1 Not UL Listed Suffix1
Number of Add to Base Product Add to Base Product
SPDT Switch Base Number for Factory List Price Base Number for Factory List Price
Breaker Type Elements Number Installation12 GO-135LG Number Installation12 GO-135LG
TQB, THQB, THHQB, TXQB, TQL, 13 TQAS2A12, 4 5 纬轩机电64.5011 – ––
THQL, THHQL, TXQL
TQC, THQC, THHQC, TXQC 13 TQCAS2A12, 4 5 纬轩机电77.5011 – ––
TQD, THQD 1 TQDAS2AB1RS N/A 纬轩机电148.006 – –
TEB, TEC, TB1 1 TEDAS2AB1R,L7,8 S 纬轩机电148.0011 TEDAS6AB1R,L7, 8 S 纬轩机电179.0011
TED, THED,THLC18 2 TEDAS2AB2R,L7,8 S 纬轩机电295.0011 TEDAS6AB2R,L7, 8 S 纬轩机电360.0011
TFC, TFJ, TFK, THFK,9 1 TFKASA2AB110 RS or LS 纬轩机电148.00 TFKASA6AB110 RS 纬轩机电167.00
THLC2, THLC4, TLB2, TLB4 2 TFKASA2AB210 RS or LS 纬轩机电295.00 TFKASA6AB210 RS 纬轩机电360.00
1 TJKASA2AB1R,L S 纬轩机电148.00 TJKASA6AB1R,L S 纬轩机电179.00
2 TJKASA2AB2R,L S 纬轩机电295.00 TJKASA6AB2R,L S 纬轩机电360.00 TJC, TJD, TJJ, TJK, THJK 3 TJKASA2AB3R,L S 纬轩机电439.00 TJKASA6AB3R,L S 纬轩机电530.00
4 TJKASA2AB4R,L S 纬轩机电598.00 TJKASA6AB4R,L S 纬轩机电712.00
1 TB4ASA2AB1R,L S 纬轩机电148.00 TB4ASA6AB1R,L S 纬轩机电179.00
2 TB4ASA2AB2R,L S 纬轩机电295.00 TB4ASA6AB2R,L S 纬轩机电360.00 TB4, TBC4 3 TB4ASA2AB3R,L S 纬轩机电439.00 TB4ASA6AB3R,L S 纬轩机电530.00
4 TB4ASA2AB4R,L S 纬轩机电598.00 TB4ASA6AB4R,L S 纬轩机电712.00
1 TKMAAS2AB1 RS or LS 纬轩机电148.00 TKMAAS6AB1 RS or LS 纬轩机电179.00
TKM, THKM, TKC, TB6, 2 TKMAAS2AB2 RS or LS 纬轩机电295.00 TKMAAS6AB2 RS or LS 纬轩机电360.00
TB8, TBC6, TBC8 3 TKMAAS2AB3 RS or LS 纬轩机电439.00 TKMAAS6AB3 RS or LS 纬轩机电530.00
4 TKMAAS2AB4 RS or LS 纬轩机电598.00 TKMAAS6AB4 RS or LS 纬轩机电712.00
1"S" suffix for wires out the side of breaker. For lead exit from back of breaker, replace suffix "S" with "B" and multiply list price by 1.25. "B" suffix not UL listed. Not available
with leads out the back for "Q-Line", or 2 element auxiliary switches used on TFG, TFJ, TFK, THFK, THLC2, THLC4, TLB2, and TLB4.
2Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers.
3Switch is SPST. Operates like "A" side of an "AB" contact and is rated six amperes at 120 Vac and three amperes at 24 Vac.
4Accessories mounted in a one-inch frame and increase overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Must be factory
installed. Maximum total breaker width is four poles.
5To order, specify both the accessory and breaker product number, e.g. THQL2130, TQASA1 identifies a 30 ampere, 2-pole plug-in breaker with a factory installed SPST auxiliary
switch.
6GO-135F.
7Auxiliary switch mounts in right pole only on two-pole TEB, TED breakers. (Factory installed only.)
8Not available with “B” suffix–leads out back.
9Changes circuit breaker interrupting capacity to 10kAIC, 600 Vac; 22 kAIC, 240 and 480 Vac.
10UL listed for field installation.
11GO-135B.
12For factory installation, contact Customer Service Center.
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
1
Components: Parts
1
1-4 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Shunt Trip
Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number List Price
Breaker Type Vac Vdc for Field Replacement for Factory Installation GO-135B
TQB, THQB, THHQB, TXQB, 120-240 TQSTA14,5,6 9 纬轩机电95.50
TQL, THQL, THHQL, TXQL 12 TQSTA74,5,6 9 纬轩机电95.50
24-48 TQSTA84,5,6 9 纬轩机电95.50
120 TQDST17,8 9 纬轩机电178.0012
240 TQDST28 9 纬轩机电178.0012
TQD, THQD 12 TQDST78 9 纬轩机电178.0012
24 TQDST88 9 纬轩机电178.0012
120 TEDST12 RS or LS7,11 纬轩机电363.00
240 TEDST12 RS or LS7,11 纬轩机电363.00
480 TEDST13 RS or LS7,11 纬轩机电363.00
TEB, TEC, TB1-B,10 600 TEDST13 RS or LS7,11 纬轩机电363.00
TED, THED, THLC1 12 TEDST7 RS or LS7,11 纬轩机电363.00
24 TEDST8 RS or LS7,11 纬轩机电363.00
48 TEDST9 RS or LS7,11 纬轩机电363.00
125 TEDST12 RS or LS7,11 纬轩机电363.00
250 TEDST11 RS or LS7,11 纬轩机电363.00
120 TFKSTA121 RS or LS 纬轩机电363.0013
240 TFKSTA121 RS or LS 纬轩机电363.0013
480 TFKSTA131 RS or LS 纬轩机电363.0013
TFC, TFJ, TFK, THFK, THLC2, 600 TFKSTA131 RS or LS 纬轩机电363.0013
THLC4, TLB2, TLB4 12 TFKSTA71 RS or LS 纬轩机电363.0013
24 TFKSTA81 RS or LS 纬轩机电363.0013
48 TFKSTA91 RS or LS 纬轩机电363.0013
125 TFKSTA121 RS or LS 纬轩机电363.0013
250 TFKSTA111 RS or LS 纬轩机电363.0013
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number
192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed.
Not available with leads out the back on "Q-Line." For factory installation, contact Customer Service Center.
4Mounts on a one-inch frame and increases overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Maximum total breaker width is
4-pole. Must be factory installed.
5Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers.
6TQST shunt trips not available on breakers over 100 A.
7Not available with “B” suffix–leads out back.
8Must be factory installed, right pole only.
9To order, specify both the accessory and breaker product number =, e.g. THQL2130, TQST1 identifies a 30 A, 2-pole plug-in breaker with a factory installed 120 Vac shunt
trip.
10For TB1 with bolt-on limiters.
11Mounts in the right pole only on 2-pole TEB, TED breakers.
12GO-135F.
13GO-135LG.
How to Order
For field replacement, order base number only. For factory installation, contact Customer
Service Center and order base number plus appropriate suffix. For a nonautomatic breaker
(molded case switch) a dummy trip is required when installing either a shunt trip or UVR.
Shunt Trip
Remote Tripping – Trips breaker by remote control. Trip coil de-energized when breaker
opens. Device meets UL requirements for service to ground fault system.
Undervoltage Release
Undervoltage release automatically trips breaker when applied coil voltage drops to 30
to 70 percent of rated value. Time-delay unit prevent nuisance tripping due to
momentary loss of voltage. Separate externally mounted unit has 120 Vac input and 125
Vdc output. Used in conjunction with 125 Vdc undervoltage release which must be
ordered separately. Product number SPUVTD for adjustable delay .1 to 1.0 seconds. List
Price 纬轩机电430.00 GO-245B.
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-5
to change without notice
Shunt Trip (continued)
Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number List Price
Breaker Type Vac Vdc for Field Replacement for Factory Installation GO-135LG
120 TJKSTA12R,L S 纬轩机电363.00
240 TJKSTA12R,L S 纬轩机电363.00
480 TJKSTA13R,L S 纬轩机电363.00
600 TJKSTA13R,L S 纬轩机电363.00
TJC, TJD, TJJ, TJK, THJK 12 TJKSTA7R,L S 纬轩机电363.00
24 TJKSTA8R,L S 纬轩机电363.00
48 TJKSTA9R,L S 纬轩机电363.00
125 TJKSTA12R,L S 纬轩机电363.00
250 TJKSTA11R,L S 纬轩机电363.00
120 TB4STA12R,L5 纬轩机电363.00
240 TB4STA12R,L5 纬轩机电363.00
480 TB4STA13R,L5 纬轩机电363.00
600 TB4STA13R,L5 纬轩机电363.00
TB4, TBC4 12 TB4STA7R,L5 纬轩机电363.00
24 TB4STA8R,L5 纬轩机电363.00
48 TB4STA9R,L5 纬轩机电363.00
125 TB4STA12R,L5 纬轩机电363.00
250 TB4STA11R,L5 纬轩机电363.00
120 TKMASTA12R,L S 纬轩机电363.00
240 TKMASTA12R,L S 纬轩机电363.00
480 TKMASTA13R,L S 纬轩机电363.00
600 TKMASTA13R,L S 纬轩机电363.00 TKC, TKM, THKM, TB6, 12 TKMASTA7R,L S 纬轩机电363.00 TB8, TBC6, TBC84 24 TKMASTA8R,L S 纬轩机电363.00
48 TKMASTA9R,L S 纬轩机电363.00
125 TKMASTA12R,L S 纬轩机电363.00
250 TKMASTA11R,L S 纬轩机电363.00
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number
192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed.
Not available with leads out the back on "Q-Line." For factory installation, contact Customer Service Center.
4Not UL listed.
5Not available for factory installation.
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
Components: Parts
1
Components: Parts
1
1-6 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Undervoltage Release
Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number List Price
Breaker Type Vac Vdc for Field Replacement for Factory Installation GO-135LG
120 TEDUV1 RS8 纬轩机电363.007
240 TEDUV2 RS8 纬轩机电363.007
480 TEDUV4 RS8 纬轩机电363.007
TEB, TEC, TB1-B5 600 TEDUV6 RS8 纬轩机电363.007
TED, THED, THLC1 12 TEDUV7 RS8 纬轩机电363.007
24 TEDUV8 RS8 纬轩机电363.007
48 TEDUV9 RS8 纬轩机电363.007
125 TEDUV10 RS8 纬轩机电363.007
250 TEDUV11 RS8 纬轩机电363.007
120 TFKUVA11 RS or LS 纬轩机电363.00
240 TFKUVA2 RS or LS 纬轩机电363.00
480 TFKUVA4 RS or LS 纬轩机电363.00
600 TFKUVA6 RS or LS 纬轩机电363.00 TFC, TFJ, TFK, THFK, THLC2, 12 TFKUVA7 RS or LS 纬轩机电363.00 THLC4, TLB2, TLB4 24 TFKUVA8 RS or LS 纬轩机电363.00
48 TFKUVA9 RS or LS 纬轩机电363.00
125 TFKUVA10 RS or LS 纬轩机电363.00
250 TDKUVA11 RS or LS 纬轩机电363.00
120 TJUV1R S 纬轩机电363.00
240 TJUV2R S 纬轩机电363.00
480 TJUV4R S 纬轩机电363.00
600 TJUV6R S 纬轩机电363.00
TJC, TJD, TJJ, TJK, THJK 12 TJUV7R S 纬轩机电363.00
24 TJUV8R S 纬轩机电363.00
48 TJUV9R S 纬轩机电363.00
125 TJUV10R S 纬轩机电363.00
250 TJUV11R S 纬轩机电363.00
120 TKUV1R S 纬轩机电363.00
240 TKUV2R S 纬轩机电363.00
480 TKUV4R S 纬轩机电363.00
TKC, TKM, THKM, TB6, 600 TKUV6R S 纬轩机电363.00
TB8, TBC6, TBC86 12 TKUV7R S 纬轩机电363.00
24 TKUV8R S 纬轩机电363.00
48 TKUV9R S 纬轩机电363.00
125 TKUV10R S 纬轩机电363.00
250 TKUV11R S 纬轩机电363.00
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1 for 120 Vac UVRs on all other breaker lines, order Product Number
192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed.
Not available with leads out the back on "Q-Line." For factory installation, contact Customer Service Center.
4For TB1 with bolt-on limiters.
5Not available with “B” suffix – leads out back.
6Not UL listed.
7GO-135B.
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-7
to change without notice
Dummy Trip1
List Price
Breaker Type Product Number GO-135LG
E150 Internal accessories for these noninterchangeable No FJ225 breakers require factory-installed dummy trips. Charge JJ400 Automatically supplied when accessories are ordered.
FK225 TFKYT2 (two-pole) 纬轩机电148.00
FK225 TFKYT3 (three-pole) 纬轩机电208.00
JK400 TJKYT3 (two-pole, three-pole) 纬轩机电212.00
JK600 TJKYT36 (two-pole, three-pole) 纬轩机电212.00
KM800 TKMAYT3 (two-pole, three-pole) 纬轩机电261.00
KM1200 TKMA3YT12 (two-pole, three-pole) 纬轩机电424.00
1Not UL listed when field installed.
2Add "B" suffix for leads exit from back of breaker; for price, multiply List Price
by 1.25. For factory installation, contact Customer Service Center.
3Not available with “B” suffix – leads out back.
4Not available for two-pole TEB, TED. Order TEDBAR.
5Changes circuit breaker interrupting capacity to: 10kA @ 600 Vac, 22kA @ 480 Vac,
22kA @ 240 Vac, for TFC, TFJ, TFK and THFK only.
6UL listed for field installation.
7Mounts in center pole with leads out left side.
8GO-135B
Bell Alarm Switches
Product Number2
Breaker UL Listed When Factory Installed List Price
Type Base No. Suffix GO-135LG
TEB, TEC, TB1 TEDBAR or S 纬轩机电154.008
TED, THED, THLC1 TEDBAL3,4 纬轩机电154.008
TFC, TFJ, TFK, THFK, TFKBAAR5,6 S 纬轩机电154.00 THLC2, THLC4, TLB4
TJC, TJJ, TJK, THJK TJKBAAL7 S 纬轩机电156.00 TB4, TBC4, TJD
TKC, TKM, THKM, TKMABAAL7 S 纬轩机电141.00 TB6, TBC6, TBC8, TB8
Blown Fuse Detector-Three-Coil Shunt Trip
Product Number2
Breaker UL Listed When Factory Installed List Price
Type Base No. Suffix GO-135LG
TED, THED, TEC3 TEDST316 RS 纬轩机电672.008
TFJ, TJK, THFK, TFC TFKBFD316 LS or RS 纬轩机电672.00
TJJ, TJK, THJK, TJD, TJC TJKST316 LS 纬轩机电672.00
TKM, THKM, TKC TKMAST316 LS 纬轩机电672.00
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
Components: Parts
1
1-8 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SED, SEH; 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adj. Inst. 18kA 25kA
Ampere Trip Range Amps Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Number GO-135S Number GO-135S Number GO-135S Range
15 43 182 SRPE30A15 纬轩机电106.00
20 58 254 SRPE30A20 纬轩机电106.00 30 SEDA24AT0030 纬轩机电214.00 SEHA24AT0030 纬轩机电530.00 25 73 332 SRPE30A25 纬轩机电106.00
30 87 415 SRPE30A30 纬轩机电106.00
40 118 501 SRPE60A40 纬轩机电106.00
50 148 637 SRPE60A50 纬轩机电106.00 60 SEDA24AT0060 纬轩机电214.00 SEHA24AT0060 纬轩机电530.00 12-3/0 Cu 60 178 777 SRPE60A60 纬轩机电106.00 TCAL18 纬轩机电3.00 12-3/0 Al 70 206 863 SRPE100A70 纬轩机电106.00
80 236 999 SRPE100A80 纬轩机电106.00 100 SEDA24AT0100 纬轩机电312.00 SEHA24AT0100 纬轩机电634.00 90 267 1138 SRPE100A90 纬轩机电106.00
100 297 1280 SRPE100A100 纬轩机电106.00
110 328 1426 SRPE150A110 纬轩机电106.00
125 374 1640 SRPE150A125 纬轩机电106.00 150 SEDA24AT0150 纬轩机电837.00 SEHA24AT0150 纬轩机电1427.00
150 450 1991 SRPE150A150 纬轩机电106.00
SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SEL, SEP2; 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adj. Inst. 65kA 100kA
Ampere Trip Range Amps Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Number GO-135S Number GO-135S Number GO-135S Range
15 43 182 SRPE30A15 纬轩机电106.00
20 58 254 SRPE30A20 纬轩机电106.00 30 SELA24AT0030 纬轩机电549.00 SEPA24AT0030 纬轩机电895.00 25 73 332 SRPE30A25 纬轩机电106.00
30 87 415 SRPE30A30 纬轩机电106.00
40 118 501 SRPE60A40 纬轩机电106.00
50 148 637 SRPE60A50 纬轩机电106.00 60 SELA24AT0060 纬轩机电549.00 SEPA24AT0060 纬轩机电895.00 12-3/0 Cu 60 178 777 SRPE60A60 纬轩机电106.00 TCAL18 纬轩机电3.00
70 206 863 SRPE100A70 纬轩机电106.00 12-3/0 Al
80 236 999 SRPE100A80 纬轩机电106.00 100 SELA24AT0100 纬轩机电744.00 SEPA24AT0100 纬轩机电1179.00 90 267 1138 SRPE100A90 纬轩机电106.00
100 297 1280 SRPE100A100 纬轩机电106.00
110 328 1426 SRPE150A110 纬轩机电106.00
125 374 1640 SRPE150A125 纬轩机电106.00 150 SELA24AT0150 纬轩机电1808.00 SEPA24AT0150 纬轩机电2777.00
150 450 1991 SRPE150A150 纬轩机电106.00
2SEL, SEP UL current limiting.
Note: All Spectra? breakers UL listed as HACR type.
All Spectra? breakers marked CE.
Product Number Structure
S E D A 2 4 A T 0030
Frame Rating Interruption Continuous Voltage Trip Trip Sensor
Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra? E = 150 D = 18 kA A = Standard 2 = 2 poles 4 = 480V A = RMS1 T = LSI1 0030
H = 25 kA 3 = 3 poles 6 = 600V 0060
L = 65 kA 0100
P = 100 kA 0150
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
Molded Case Circuit Breakers
Industrial Circuit Breaker Accessories
15-150A Circuit Breakers, Electronic Trip, Spectra? RMS, SE150 Line Circuit Breakers
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-9
to change without notice
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGD, SGH; UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
Adjustable
UL 489 IC @480 Vac UL 489 IC @480 Vac
Instantaneous 65kA (240 Vac) 35kA
Ampere Trip Ampere Range Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Poles Number GO-135S Number GO-135S Number GO-135S Range
125 380 1275 SRPG400A125 纬轩机电106.00 2-pole lug kit 150 455 1530 SRPG400A150 纬轩机电106.00 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 纬轩机电106.00 2 SGDA22AT04004 纬轩机电1540.00 SGHA26AT0400 纬轩机电1959.00 TCLK2655 纬轩机电28.00 or
200 605 2040 SRPG400A200 纬轩机电106.00 (1) 8-600 Cu
225 680 2295 SRPG400A225 纬轩机电106.00 400
250 755 2550 SRPG400A250 纬轩机电106.00 3-pole lug kit 300 905 3060 SRPG400A300 纬轩机电106.00 3 SGDA32AT04004 纬轩机电1860.00 SGHA36AT0400 纬轩机电2383.00 (2) 2/0-500 Al
350 1060 3570 SRPG400A350 纬轩机电106.00 TCLK3655 纬轩机电42.00 or
400 1210 4080 SRPG400A400 纬轩机电106.00 (1) 8-600 Al
4Rated 240 Vac max.
5Order one kit for either line or load end; two kits required for both.
Note: All Spectra? breakers UL listed as HACR type. All Spectra? breakers marked CE.
125-600A Circuit Breakers, Electronic Trip, Spectra? RMS, SG600 Digital, Solid-State Spectra? RMS Breakers
70-250A Circuit Breakers, Electronic Trip, Spectra? RMS, SF250 Line Circuit Breakers
SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SFH; 2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
Adjustable Instantaneous
UL 489 IC @480 Vac
Trip Ampere Range
35kA
Ampere Product List Price Current Product List Price Product List Price Wire
Rating Low Hi gh Number GO-135S Sensor Number GO-135S Number GO-135S Range
70 205 700 SRPF250A70 纬轩机电106.00
90 265 900 SRPF250A90 纬轩机电106.00
100 295 1000 SRPF250A100 纬轩机电106.00
110 325 1100 SRPF250A110 纬轩机电106.00 8-350 Cu 125 370 1250 SRPF250A125 纬轩机电106.00 250 SFHA24AT0250 纬轩机电1134.00 TCAL29 纬轩机电8.00 150 440 1500 SRPF250A150 纬轩机电106.00 8-350 Al
175 515 1750 SRPF250A175 纬轩机电106.00
200 590 2000 SRPF250A200 纬轩机电106.00
225 665 2250 SRPF250A225 纬轩机电106.00
250 736 2500 SRPF250A250 纬轩机电106.00
Molded Case Circuit Breakers
Industrial Circuit Breaker Accessories
Product Number Structure
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
S F H A 2 4 A T 0250
Frame Rating Interruption Continuous Voltage Trip Trip Sensor
Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra? F = 250 H = 35 kA A = Standard 2 = 2 poles 4 = 480V A = RMS1 T = LSI1 0250
L = 65 kA 3 = 3 poles 6 = 600V
P = 100 kA
Product Number Structure
S G D A 2 2 A T 0400
Frame Rating Interruption Continuous Voltage Trip Trip Sensor
Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra? G = 600 D = 65 kA2 A = Standard 2 = 2 poles 2 = 240V A = RMS1 T = LSI3 0400
H = 35 kA H = 100% 3 = 3 poles 6 = 600V 0600
L = 65 kA L = 100%
P = 100 kA P = 100% 2 SGD rated 65kA at 240V.
3Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
Components: Parts
1
1-10 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
Adjustable
UL 489 IC @480 Vac UL 489 IC @480 Vac
Instantaneous 50kA 65kA
Ampere Trip Ampere Range Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Poles Number GO-135S Number GO-135S Number GO-135S Range
300 940 3015 SRPK800A300 纬轩机电106.00
400 1255 4015 SRPK800A400 纬轩机电106.00 2 SKHA26AT0800 纬轩机电3377.00 SKLA26AT0800 纬轩机电4301.00 (3) 3/0-500 Cu
500 1570 5020 SRPK800A500 纬轩机电106.00 800 TCAL81 纬轩机电47.00 600 1875 6195 SRPK800A600 纬轩机电106.00
700 2155 7420 SRPK800A700 纬轩机电106.00 3 SKHA36AT0800 纬轩机电4323.00 SKLA36AT0800 纬轩机电5234.00 (3) 3/0-500 Al 800 2440 8705 SRPK800A800 纬轩机电106.00
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
Adjustable
UL 489 IC @480 Vac UL 489 IC @480 Vac
Instantaneous 50kA 65kA
Ampere Trip Ampere Range Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Poles Number GO-135S Number GO-135S Number GO-135S Range
600 1825 6110 SRPK1200A600 纬轩机电106.00
700 2125 7125 SRPK1200A700 纬轩机电106.00 2 SKHA26AT1200 纬轩机电7057.00 SKLA26AT1200 纬轩机电7958.00 (4) 250-500 Cu
800 2430 8145 SRPK1200A800 纬轩机电106.00 1200 TCAL125 纬轩机电76.00 900 2735 9160 SRPK1200A900 纬轩机电106.00
1000 3040 10180 SRPK1200A1000 纬轩机电106.00 3 SKHA36AT1200 纬轩机电7679.00 SKLA36AT1200 纬轩机电8586.00 (4) 250-500 Al 1200 3650 12215 SRPK1200A1200 纬轩机电106.00
Note: All Spectra? breakers UL listed as HACR type.
All Spectra? breakers marked CE.
Molded Case Circuit Breakers
Industrial Circuit Breaker Accessories
Product Number Structure
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
S K H A 2 6 A T 0800
Frame Rating Interruption Continuous Voltage Trip Trip Sensor
Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra? K = 1200 H = 50 kA A = Standard 2 = 2 poles 6 = 600V A = RMS1 T = LSI1 0800
L = 65 kA H = 100% 3 = 3 poles 1200
P = 100 kA L = 100%
P = 100%
300-1200A Circuit Breakers, Electronic Trip, Spectra? RMS
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-11
to change without notice
MicroVersaTrip? Plus and PM Rating Plug Selection —
All Plugs List Price 纬轩机电106.00, GO-135S
Circuit Breaker Sensor Rating Plug Rating Plug
Frame Rating Rating (Amperes) Product No.
150 60 SRPG150B60
80 SRPG150B80
100 SRPG150B100
125 SRPG150B125
150 SRPG150B150
400 150 SRPG400B150
200 SRPG400B200
SGHB, SGHH, SGLB, 225 SRPG400B225
SGLL, SGPB, SGPP 250 SRPG400B250
300 SRPG400B300
350 SRPG400B350
400 SRPG400B400
600 300 SRPG600B300
400 SRPG600B400
450 SRPG600B450
500 SRPG600B500
600 SRPG600B600
1MicroVersaTrip? PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 1-12 to 1-14.
Note: All Spectra? breakers UL listed as HACR type.
All Spectra? breakers marked CE.
Microversatrip? Plus and PM Rating Plug Selection —
All Plugs List Price 纬轩机电106.00, GO-135S
Circuit Breaker Sensor Rating Plug Rating Plug
Frame Rating Rating (Amperes) Product No.
300 SRPK800B300
400 SRPK800B400
800 500 SRPK800B500
600 SRPK800B600
SKHB, SKHH, SKLB, 700 SRPK800B700
SKLL, SKPB, SKPP 800 SRPK800B800
600 SRPK1200B600
700 SRPK1200B700
1200 800 SRPK1200B800
1000 SRPK1200B1000
1200 SRPK1200B12002
1Microversatrip? PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 1-12 to 1-14.
2Not suitable for use with 100% rated, 1000A breaker frame.
Note: All Spectra? breakers UL listed as HACR type.
All Spectra? breakers marked CE.
300-1200A Circuit Breakers, Electronic Trip, Spectra? RMS, SK1200 with MicroVersaTrip? Plus and PM1
60-600A Circuit Breakers, Electronic Trip, Spectra? RMS , with MicroVersaTrip? PM Trip Unit1
Molded Case Circuit Breakers
Industrial Circuit Breaker Accessories
Rating Plugs
Components: Parts
1
1-12 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Molded Case Circuit Breakers
Power Management System Accessories
Spectra? RMS Circuit Breakers with MicroVersaTrip? Plus and MicroVersaTrip? PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)
Required Accessories
Type Accessories
Standard –
Ground Fault Option with 3-phase, 4-wire Neutral Current Sensor and Terminal Block
MicroVersaTrip? Plus Trip Unit or 1-phase, 3-wire service or Neutral Current Sensor and Junction Box
Control Power Option Power Supply Plate or Voltage Module1 or Power Supply Assembly2
Power Supply Plate and Voltage Conditioner Plate or Voltage Module1
Standard or with Protective Relaying or Power Supply Assembly2 and Voltage Conditioner Assembly2
MicroVersaTrip? PM Trip Unit Junction Box, Cable Harness and Auxiliary Switch
Ground Fault Option with 3-phase, 4-wire Neutral Current Sensor
or 1-phase, 3-wire service
1For installation into GE Spectra? Series Switchboards only.
2Requires fuse protection and other components; refer to accessory detail for additional information.
Power Supply Plate
The Power Supply Plate is used to provide +24 Vdc control power to Spectra? RMS Molded
Case Circuit Breakers with MicroVersaTrip? PM or MicroVersaTrip? Plus trip systems via the
Distribution Cable System. The Power Supply Plate includes the Power Supply Assembly
(product number SPSAA) as an integral component and also includes fuse protection for AC
source input. Supplemental +24 Vdc input terminals are provided for backup control power
applications. Five versions are available. Not suitable for 400 Hz. List Price
Description Voltage Rating Product Number GO-135PM
The Power Supply Plate is rated 24 watts 120 Vac SPSA120 纬轩机电1215.00
(+24 Vdc at 1.0 amperes) and has the maximum 208 Vac SPSA208 纬轩机电1215.00
capacity to power a distribution Cable System 240 Vac SPSA240 纬轩机电1215.00
consisting of 20 breakers and has a maximum 480 Vac SPSA480 纬轩机电1215.00
system cable length of 40 feet. 600 Vac SPSA600 纬轩机电1215.00
Voltage Conditoner Plate
The Voltage Conditioner Plate is used to provide voltage sensing signals to Spectra?
RMS Molded Case Circuit Breakers with MicroVersaTrip? PM Trip Units via the Distribution
Cable System. The Voltage Conditioner Plate includes the Voltage Conditioner Assembly
(product number SVCAA) as an integral component and also includes fuse protection
for the AC source input terminals and three 1-VA high accuracy potential transformers.
The Voltage Conditioner Plate requires a control power source of +24 Vdc to operate properly
(the Power Supply Assembly or Power Supply Plate can provide this required input). The unit
also requires AC direct voltage inputs from the AC source. A GE POWER LEADER? network
(commnet) connection is provided. Seven versions are available. Not suitable for 400 Hz. List Price
Voltage Rating and Service Type Comments Product Number GO-135PM
120 Vac Wye system Phase to Neutral potential SVCA120Y 纬轩机电1000.00
208 Vac Wye system Phase to Phase potential SVCA208Y 纬轩机电1000.00
240 Vac Delta system Phase to Phase potential SVCA240D 纬轩机电1000.00
277 Vac Wye system Phase to Neutral potential SVCA277Y 纬轩机电1000.00
480 Vac Wye system Phase to Phase potential SVCA480Y 纬轩机电1000.00
480 Vac Delta system Phase to Phase potential SVCA480D 纬轩机电1000.00
600 Vac Delta system Phase to Phase potential SVCA600D 纬轩机电1000.00
Note: The Voltage Conditoner Plate has the maximum capacity to power a Distribution Cable System consisting of
20 breakers and has a maximum system cable length of 40 feet.
Distribution Cable Junction Box
The Distribution Cable Junction Box is a modular connector used to provide quick, easy and
reliable attachment of Spectra? RMS Molded Case Circuit Breakers with MicroVersaTrip? Plus
trip systems or MicroVersaTrip? PM trip systems to the Distribution Cable System. The Junction
Box contains two Distribution Cable Harness plugs, one breaker plug and a terminal block for
the connection of a neutral current sensor and an auxiliary switch. Product number SDCJBA
is for general purpose OEM applications. Product number SDCJBB is designed for mounting
in Spectra? Series Panelboards. List Price
Description Product Number GO-135PM
Distribution Cable Junction Box SDCJBA3 纬轩机电155.00
Distribution Cable Junction Box SDCJBB 纬轩机电155.00
3Limited availability—obselete when inventory depleted.
Power Supply Plate
Voltage Conditioner Plate
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-13
to change without notice
Molded Case Circuit Breakers
Power Management System Accessories
Spectra? RMS Circuit Breakers with MicroVersaTrip? Plus and MicroVersaTrip? PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)
Distribution Cable Harness3
The Distribution Cable Harness is a modular connector used to carry electronic signals
and/or control power between Spectra? RMS Molded Case Circuit Breakers with
MicroVersaTrip? Plus or MicroVersaTrip? PM Trip Units and Distribution Cable accessories.
The harnesses come in three lengths. List Price
Description Harness Length Product Number GO-135PM
Distribution Cable Harness 11 inches SDCHA11 纬轩机电70.00
Distribution Cable Harness 30 inches SDCHA30 纬轩机电80.00
Distribution Cable Harness 60 inches SDCHA60 纬轩机电100.00
3Cannot be connected together. Use 30 inch Distribution Cable Extension (SDCEA30) to extend.
Distribution Cable Extension
The Distribution Cable Extension is used to provide modular expansion of the Distribution
Cable System. List Price
Description Harness Length Product Number GO-135PM
Distribution Cable Extension 30 inches SDCEA30 纬轩机电80.00
Distribution Cable Terminal Block
The Distribution Cable Terminal Block is a modular attachment primarily used to provide
an alternate means of input to Spectra? RMS Molded Case Circuit Breakers with
MicroVersaTrip? Plus or MicroVersaTrip? PM Trip Units. The Terminal Block plugs into the
breaker distribution cable receptacle allowing the direct connection of breaker signals
via screw terminals. This allows point-to-point wiring of breakers instead of using the
Distribution Cable System. List Price
Description Product Number GO-135PM
Distribution Cable Terminal Block SDCTBA11 纬轩机电110.00
Power Supply Assembly
The Power Supply Assembly is used to provide +24 Vdc Control Power to Spectra? RMS
Molded Case Circuit Breakers with MicroVersaTrip? Plus or MicroVersaTrip? PM trip systems
via the Distribution Cable System. The assembly requires a minimum input voltage of 85
Vac to operate properly (the maximum voltage rating is 240 Vac). Supplemental +24 Vdc
input terminals are provided for backup control power applications. The input must be
fused with 1/2 ampere class CC fuses (not included). Not suitable for 400 Hz. List Price
Description Voltage Rating Product Number GO-135PM
The Power Supply Assembly is rated 24 watts 85 - 240 Vac SPSAA 纬轩机电1000.00
(+24 Vdc @ 1.0 ampere) and has the maximum
capacity to power a Distribution Cable System
consisting of 20 breakers and has a maximum
system cable length of 40 feet.
Distribution Cable Extension
Distribution Cable Terminal Block
Power Supply Assembly
Required Accessories
Type Accessories
Standard –
Ground Fault Option with 3-phase, 4-wire Neutral Current Sensor and Terminal Block
MicroVersaTrip? Plus Trip Unit or 1-phase, 3-wire service or Neutral Current Sensor and Junction Box
Control Power Option Power Supply Plate or Voltage Module1 or Power Supply Assembly2
Power Supply Plate and Voltage Conditioner Plate or Voltage Module1
Standard or with Protective Relaying or Power Supply Assembly2 and Voltage Conditioner Assembly2
MicroVersaTrip? PM Trip Unit Junction Box, Cable Harness and Auxiliary Switch
Ground Fault Option with 3-phase, 4-wire Neutral Current Sensor
or 1-phase, 3-wire service
1For installation into GE Spectra? Series Switchboards only.
2Requires fuse protection and other components; refer to accessory detail for additional information.
Distribution Cable Harness
Components: Parts
1
1-14 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Molded Case Circuit Breakers
Power Management System Accessories
Spectra? RMS Circuit Breakers with MicroVersaTrip? Plus and MicroVersaTrip? PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)
Voltage Modules
The Voltage Module is used primarily as a Spectra? Series Switchboard component
to provide +24 Vdc Control Power to Spectra? RMS Molded Case Circuit Breakers with
MicroVersaTrip? Plus or MicroVersaTrip? PM Trip Units via the Distribution Cable System.
The Module also provides voltage sensing signals to Spectra? RMS Molded Case Circuit
Breakers with MicroVersaTrip? PM Trip Units on the same Distribution Cable System. The
Module contains both a Power Supply Plate and a Voltage Conditioner as integral components.
It also includes fuse protection for the AC source input terminals (the modules
pressure connectors which mate with the switchboard interior bus bars). A GE POWER
LEADER? Network (commnet) connection is provided as well as supplemental 24 Vdc
input terminals for backup control power applications. Seven versions are available. Not
suitable for 400 Hz.
List Price
Voltage Rating and Service Type Comments Product Number GO-135PM
120 Vac Wye system Phase to Neutral potential ADSVMA120Y 纬轩机电2350.00
208 Vac Wye system Phase to Phase potential ADSVMA208Y 纬轩机电2350.00
240 Vac Delta system Phase to Phase potential ADSVMA240D 纬轩机电2350.00
277 Vac Wye system Phase to Neutral potential ADSVMA277Y 纬轩机电2350.00
480 Vac Wye system Phase to Phase potential ADSVMA480Y 纬轩机电2350.00
480 Vac Delta system Phase to Phase potential ADSVMA480D 纬轩机电2350.00
600 Vac Delta system Phase to Phase potential ADSVMA600D 纬轩机电2350.00
Note: The Voltage Module has the maximum capacity to power a Distribution Cable System consisting of 20
breakers and has a maximum system cable length of 40 feet.
Voltage Module Exterior View Voltage Module Interior View
Voltage Conditioner Assembly
Voltage Conditioner Assembly
The Voltage Conditioner Assembly is used to provide voltage sensing signals to Spectra?
RMS Molded Case Circuit Breakers with MicroVersaTrip? PM Trip Units via the Distribution
Cable System. The Voltage Conditioner Assembly requires a control power source of +24
Vdc to operate properly (the Power Supply Assembly or Power Supply Plate can provide
this required input). The unit also requires 120 Vac voltage inputs from the secondary
of three 1-VA high accuracy potential transformers (not included). The primary side of
the potential transformers must be fused with three, 1/2 ampere class CC fuses (not
included). A GE POWER LEADER? network (commnet) connection is provided. Not suitable
for 400 Hz.
List Price
Description Voltage Rating Product Number GO-135PM
Requires 120 Vac voltage inputs from the 120 Vac SVCAA 纬轩机电680.00
secondary of three 1.0 VA high accuracy
potential transformers
Note: the Voltage Conditioner Assembly has the maximum capacity to power a Distribution Cable System
consisting of 20 breakers and has a maximum system cable length of 40 feet.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-15
to change without notice
Molded Case Circuit Breakers
Accessories–Other
Spectra? RMS Circuit Breakers with MicroVersaTrip? Plus and MicroVersaTrip? PM Trip Units
All Devices UL Listed for Factory or Field Installation Except Where Noted
Neutral Current Sensor
The neutral current sensor is used in conjunction with breakers that have a MicroVersaTrip?
Plus or MicroVersaTrip? PM Trip Unit with the optional ground fault function and the breaker
is connected to a grounded neutral service (3-phase, 4-wire or 1-phase, 3-wire). The neutral
current sensor provides an input signal to the breaker trip unit. Breakers connected to a
service without a neutral (3-phase, 3-wire) require no external connection or shorting of
the breaker cable connector for ground fault to function properly.
List Price
Breaker Type Sensor Rating (S) Product Number GO-135S
SG 150 TSRG201 纬轩机电532.00
SG 400 TSRG204 纬轩机电532.00
SG 600 TSRG206 纬轩机电532.00
SK 800 TSKG408 纬轩机电532.00
SK 1200 TSKG412 纬轩机电532.00
Voltage Current (mA) Product List Price
ac dc Inrush Cont Number GO-135S
120 125 500 6.0 SAST1 纬轩机电363.00
240 250 400 5.0 SAST2 纬轩机电363.00
— 12 1000 800 SAST51 纬轩机电363.00
24 24 300 10.0 SAST3 纬轩机电363.00
48 48 300 10.0 SAST4 纬轩机电363.00
1Not suitable for use with ground fault sensing and relaying equipment.
Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.
Auxiliary Switch
Auxiliary switches provide remote indication of whether the circuit breaker main
contacts are opened or closed via open or closed SPDT switch elements.
Switch Number of Auxiliary Switch List Price
Rating Switch Elements Product Number GO-135S
5A @240 Vac/ 1 form C SAUXPAB1 纬轩机电149.00
0.5A @ 125 Vdc 2 form C SAUXPAB2 纬轩机电295.00
Gold-Plated Contacts 1 form C SAUXGAB1 纬轩机电149.00
0.5A @ 30V 2 form C SAUXGAB2 纬轩机电295.00
One each 2 form C SAUXGPAB2 纬轩机电295.00
of above types
Shunt Trip
For remote tripping of breaker, use with momentary close contact. Not recommended for
use with latching relay contact since electronics in shunt trip will pulse power to the coil
if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2
seconds at rated control voltage. (A short-circuit trip would be instantaneous.)
If maintained (latching relay) contact must be used and delayed shunt tripping is not
acceptable, use small bell alarm in series with control power for SE150 and SF250 frames
and auxiliary switch for SG600 and SK1200 breakers.
These devices are suitable for use with ground fault sensing and relaying equipment.
Maximum VA is 75. AC devices are UL listed for 50-60 Hz.
Red
White
Brown/white
Black
Black
All accessory contacts shown
with the circuit breaker in
tripped position.
All accessory contacts shown
with the circuit breaker in
tripped position.
Auxiliary Switch
Shunt Trip
Internal Accessories, Spectra? RMS Circuit Breakers
Components: Parts
1
1-16 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Actuator
All Spectra? circuit breakers are supplied with an actuator installed in the left-side pouch.
The actuator is removed when installing either a shunt trip or undervoltage release.
List Price
Description Product Number GO-148C
Replacement Actuator SACTUATOR 纬轩机电250.00
Voltage Peak Current Product List Price
ac dc (mA) Number GO-135S
120 125 200 SAUV1 纬轩机电363.00
240 250 200 SAUV2 纬轩机电363.00
24 24 100 SAUV3 纬轩机电363.00
48 48 100 SAUV4 纬轩机电363.00
120 125 SPUVTD 纬轩机电430.001
1GO-245B.
Switch Number of Product List Price
Rating Switch Elements Number GO-135S
5A @ 240 Vac/ 1 form C SABAP1 纬轩机电154.00 0.5A @ 125 Vdc
Gold-Plated Contacts 1 form C SABAG1 纬轩机电154.00 0.5A @30V
Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.
Bell Alarm Switch
The bell alarm switch provides remote indication of whether the circuit breaker has been
tripped via open or closed SPDT switch elements, but remains unchanged during "On/Off"
circuit breaker operation and during operation by the "Push-to-Trip" button.
Undervoltage Release
Undervoltage Release
The undervoltage release provides automatic circuit breaker tripping when there is a
power loss or major dip (to 35%-70% of rated voltage) in accessory control voltage. AC
devices are UL listed for 50-60 Hz. Product number SAUV1 may be used with time delay
unit SPUVTD (List Price 纬轩机电430.00, GO-245B) (delay 0.1 to 1.0 seconds), 120 Vac input,
125 Vdc output.
Bell Alarm Switch
Purple
Yellow
Brown
Blue
Blue
All accessory contacts shown
with the circuit breaker in
tripped position.
All accessory contacts shown
with the circuit breaker in
tripped position.
Molded Case Circuit Breakers
Internal Accessories
Spectra? RMS Circuit Breakers
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-17
to change without notice
Contacts – Auxiliary and Bell Alarm (Rated 5A @240VAC, 0.5A @125VDC)
Normally Open Normally Closed
List Price List Price
Accessory Product No. GO-135H Product No. GO-135H
Aux. Switch Right Mounted FAS10RW 纬轩机电149.00 FAS01RW 纬轩机电149.00
Aux. Switch Left Mounted FAS10LW 纬轩机电149.00 FAS01LW 纬轩机电149.0
Bell Alarm Mechanism FABAM10W 纬轩机电154.00 FABAM01W 纬轩机电154.00
Releases – Shunt Trip and Undervoltage
Shunt Trip Undervoltage Release
Rating (Inrush List Price Rating (Inrush List Price
Voltage Power Consumption) Product No. GO-135H Power Consumption) Product No. GO-135H
12 VDC 200 mA / 2.4W FASHTBW 纬轩机电363.00 — ——
24 VAC/DC 100 mA / 3.6W FASHTDW 纬轩机电363.00 50 mA / 1.2W FAUVRDW 纬轩机电363.00
48 VAC/DC 60 mA / 2.88W FASHTFW 纬轩机电363.00 20 mA / 0.96W FAUVRFW 纬轩机电363.00
120 VAC 40 mA / 4.8W FASHTKW 纬轩机电363.00 — ——
110/130 VAC/DC 40 mA / 4.8W FASHTJW 纬轩机电363.00 15 mA / 1.8W FAUVRJW 纬轩机电363.00
220/240 VAC, 250 VDC 20 mA / 4.6W FASHTNW 纬轩机电363.00 15 mA / 3.45W FAUVRNW 纬轩机电363.00
277 VAC 11 mA / 3.0W FASHT7W 纬轩机电363.00 15 mA / 4.0W FAUVR7W 纬轩机电363.00
400/480 VAC 20 mA / 8.4W FASHTUW 纬轩机电363.00 15 mA / 6.3W FAUVRUW 纬轩机电363.00
Auxiliary Switch/Bell Alarm Mechanism
Shunt Trip/Undervoltage Release
Molded Case Circuit Breakers
Accessories
Record Plus? FC 100
Lugs and Lug Kits
Single Lug List Price Lug Kit List Price
Amp Range Wire Range Strip Length Product No. GO-135H Product No. (Set of 3) GO-135H
15-20A 14-10 Cu/Al .40-.50” FCAL12 纬轩机电3.25 FCALK12 纬轩机电9.00
25-60A 10-4 Cu/Al .40-.50” FCAL13 纬轩机电3.25 FCALK13 纬轩机电9.00
70-100A 4-1/0 Cu/Al .40-.50” FCAL14 纬轩机电3.25 FCALK14 纬轩机电9.00
External Accessories
Components: Parts
1
1-18 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Molded Case Circuit Breakers
Accessories
Record Plus? FE 250
FE Rating Plugs List Price
Trip Curve CT Rating Rated Current Product No. GO-135H
25A 20 A FERP3B0020 纬轩机电106.00
25 A FERP3B0025 纬轩机电106.00
30 A FERP3D0030 纬轩机电106.00
40 A FERP3D0040 纬轩机电106.00 60A 50 A FERP3D0050 纬轩机电106.00
60 A FERP3D0060 纬轩机电106.00
70 A FERP3G0070 纬轩机电106.00
80 A FERP3G0080 纬轩机电106.00
DES-200 90 A FERP3G0090 纬轩机电106.00 125A 100 A FERP3G0100 纬轩机电106.00
110 A FERP3G0110 纬轩机电106.00
125 A FERP3G0125 纬轩机电106.00
150A 150 A FERP3H0150 纬轩机电106.00
175 A FERP3K0150 纬轩机电106.00
200 A FERP3K0200 纬轩机电106.00 250A 225 A FERP3K0225 纬轩机电106.00
250 A FERP3K0250 纬轩机电106.00
Bell Alarm
Contact List Price
Configuration Contact Rating Wire leads Product No. GO-135H
1 NO (Form A) 5A @ 277 VAC, #16 AWG FABAM10W 纬轩机电154.00
0.3A @ 125 VDC
1 NC (Form B) 5A @ 277 VAC, #16 AWG FABAM01W 纬轩机电154.00
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Internal and External Accessories
Neutral Grounds and Sensors
Neutral Current Sensors
For grounded neutral system ground fault applications
List Price
Breaker Type Ampere Rating Product Number GO-135S
150 TSRG201 纬轩机电532.00
200 TSRG202 纬轩机电532.00
300 TSRG203 纬轩机电532.00 J 400 TSRG204 纬轩机电532.00
500 TSRG205 纬轩机电532.00
600 TSRG206 纬轩机电532.00
800 TSKG408 纬轩机电532.00
K 1000 TSKG410 纬轩机电532.00
1200 TSKG412 纬轩机电532.00 Neutral Current Sensor
Breaker Frames & Ratings Plugs
Insulated Case Circuit Breakers
Circuit Breakers History/Timeline
GE Insulated Case Circuit Breakers History/Timeline
1965 GE pioneered the design of insulated case circuit breakers when it introduced the original
Power Break? circuit breaker.
1995 GE introduced Power Break? II insulated case circuit breakers, the vanguard of a new age in reliable, flexible
and easy-to-use circuit protection.
Evolution of the GE Trip Unit
1965 Dual Magnetic Trip
1975 VersaTrip Solid State Trip
1979 VersaTrip Mod 2 Solid State Trip
1979 Magnetrip-Dual Mag
1979 SelecTrip
1982 MicroVersaTrip?
1988 MicroVersaTrip? RMS 9
1989 MicroVersaTrip? RMS 9 / Epic
1994 MicroVersaTrip? Plus/PM
1995 Enhanced MicroVersaTrip? Plus/PM
1996 Power Break? II MicroVersaTrip? Plus/PM
1997 Power Break? II Powerplus
2009 EntelliGuard? TU
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-19
to change without notice
This catalog contains replacement parts, retrofits, accessories,
and older generation products. For current generation products,
please see the GE BuyLog? or Control Catalog.
Components: Parts
1
1-20 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Enhanced MicroVersaTrip?, Rating Plug Selection
Power Break? II Rating Plug Selection
Enhanced
MicroVersaTrip? Plus
Power+ Trip and Enhanced
Power+ Trip Unit Ground MicroVersaTrip? PM
Unit Standard Fault Rating Trip Unit
Frame Sensor Current Rating Plugs Plugs Rating Plugs
Size Rating Rating List Price 纬轩机电89.00 List Price 纬轩机电747.00 List Price 纬轩机电89.00
(Amperes) (Amperes) (Amperes) GO-245A GO-245A GO-245A
100 TR2C100 TR2C100GF TR2B100
200 150 TR2C150 TR2C150GF TR2B150
200 TR2C200 TR2C200GF TR2B200
150 – – TR4B150
800 200 TR4C200 TR4C200GF TR4B200
225 TR4C225 TR4C225GF TR4B225 400 250 TR4C250 TR4C250GF TR4B250
300 TR4C300 TR4C300GF TR4B300
400 TR4C400 TR4C400GF TR4B400
300 – – TR8B300
400 TR8C400 TR8C400GF TR8B400
450 TR8C450 TR8C450GF TR8B450
800-1600 800 500 TR8C500 TR8C500GF TR8B500
600 TR8C600 TR8C600GF TR8B600
700 TR8C700 TR8C700GF TR8B700
800 TR8C800 TR8C800GF TR8B800
400 – – TR10B400
1000 600 TR10C600 TR10C600GF TR10B600
800 TR10C800 TR10C800GF TR10B800
1000 TR10C1000 TR10C1000GF TR10B1000
1600 600 – – TR16B600
800 TR16C800 TR16C800GF TR16B800
1600 1000 TR16C1000 TR16C1000GF TR16B1000
1100 TR16C1100 TR16C1100GF TR16B1100
1200 TR16C1200 TR16C1200GF TR16B1200
1600 TR16C1600 TR16C1600GF TR16B1600
750 – – TR20B750
800 – – TR20B800
1000 TR20C1000 TR20C1000GF TR20B1000
2000 2000 1200 TR20C1200 TR20C1200GF TR20B1200
1500 TR20C1500 TR20C1500GF TR20B1500
1600 TR20C1600 TR20C1600GF TR20B1600
2000 TR20C2000 TR20C2000GF TR20B2000
400 – – TR10B400
600 TR10C600 TR10C600GF TR10B600 1000 800 TR10C800 TR10C800GF TR10B800
1000 TR10C1000 TR10C1000GF TR10B1000
750 – – TR20B750
800 – – TR20B800
1000 TR20C1000 TR20C1000GF TR20B1000 2500 2000 1200 TR20C1200 TR20C1200GF TR20B1200
1500 TR20C1500 TR20C1500GF TR20B1500
1600 TR20C1600 TR20C1600GF TR20B1600
2000 TR20C2000 TR20C2000GF TR20B2000
1600 TR25C1600 TR25C1600GF TR25B1600
2500 2000 TR25C2000 TR25C2000GF TR25B2000
2500 TR25C2500 TR25C2500GF TR25B2500
1200 – – TR30B1200
1600 – – TR30B1600
3000 3000 2000 TR30C2000 TR30C2000GF TR30B2000
2500 TR30C2500 TR30C2500GF TR30B2500
3000 TR30C3000 TR30C3000GF TR30B3000
1600 TR40C1600 TR40C1600GF TR40B1600
2000 TR40C2000 TR40C2000GF TR40B2000
4000 4000 2500 TR40C2500 TR40C2500GF TR40B2500
3000 TR40C3000 TR40C3000GF TR40B3000
3600 TR40C3600 TR40C3600GF TR40B3600
4000 TR40C4000 TR40C4000GF TR40B4000
MicroVersaTrip? and MicroVersaTrip? PM Rating Plug
Trip Indicator Product List Price
L/ST/1 Ground Fault Number GO-245A
– – TARGET00 纬轩机电60.00
? – TARGET01 纬轩机电140.00
? ? TARGET02 纬轩机电160.00
Power+ Target Module
Power+ trip units are designed to accept an optional field-installable
target module. The target module indicates long-time pickup, battery
status, trip unit health status, and whether a breaker trip was
caused by an overload, a short circuit or a ground fault. Target
modules are available with or without ground fault indication.
Power+ Trip Target Module
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-21
to change without notice
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
120 – SPE120R 纬轩机电1671.00 SPE120 纬轩机电1838.00
240 – SPE240R 纬轩机电1869.00 SPE240 纬轩机电2056.00
– 24 SPE024R 纬轩机电1869.00 SPE024 纬轩机电2056.00
– 48 SPE048R 纬轩机电1869.00 SPE048 纬轩机电2056.00
– 72 SPE072R 纬轩机电1869.00 SPE072 纬轩机电2056.00
– 125 SPE125R 纬轩机电1869.00 SPE125 纬轩机电2056.00
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
120 – SPRCS120R 纬轩机电286.00 SPRCS120 纬轩机电315.00
240 – SPRCS240R 纬轩机电286.00 SPRCS240 纬轩机电315.00
– 24 SPRCS024R 纬轩机电286.00 SPRCS024 纬轩机电315.00
– 48 SPRCS048R 纬轩机电286.00 SPRCS048 纬轩机电315.00
– 72 SPRCS072R 纬轩机电286.00 SPRCS072 纬轩机电315.00
– 125 SPRCS125R 纬轩机电286.00 SPRCS125 纬轩机电315.00
Electrical Operator
Remote Close Solenoid
This accessory provides an electrically operated solenoid which, when energized, closes
the breaker. It is suitable for control interlock schemes in which manual closing capability
would not be convenient or desirable. The breaker is provided with a manual close
button, which can be replaced by the Hidden "ON" Button accessory and/or sealed using
the Limited Access Pushbutton Cover accessory. The remote close accessory is continuously
rated and has an anti-pump feature, which prevents a motor operated breaker
from repeatedly closing into a fault. Closing control voltage must be removed and re-applied
for each breaker closure.
Remote Close Solenoid
Accessories—Stationary and Draw-out Breakers
The complete line of Power Break? II breaker accessories may be either factory or field
installed to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm with
mechanical lockout, and the undervoltage release modules are drop-in from the front of
the breaker, interchangeable across all frames, and require no field internal wiring or
breaker disassembly. Auxiliary switch modules are available in groups of 4, 8 or 12,
NO/NC single-pole, double-throw (SPDT) switches. Their installation simply involves
removal of breaker cover, installation of the switch module, routing of wiring and installation
of the pre-wired terminal block and re-installation of the cover. Auxiliary switches
are also interchangeable across all Power Break? II breaker frames.
Electrical Operator
The electrical operator mounts inside the front cover of the manually operated breaker.
This accessory can be added to any Power Break? II breaker in the factory or the field
to provide electrical spring charging and charge indication. For remote closing, the
remote close solenoid must be priced and ordered separately. All breakers are
prewired to dedicated secondary terminals for easy field installation. When electrical
operation is used, either a shunt trip or an undervoltage release must be ordered and
priced separately.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-22 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Shunt Trip
The shunt trip accessory is an electronic module, which provides remote control capability
to open the circuit breaker. When activated, the shunt trip module sends a signal to
the trip unit to open the breaker. This allows the trip unit to record, display, distinguish
and communicate (in MicroVersaTrip? PM trip units) that the opening event was initiated
by the shunt trip device. The shunt trip is continuously rated and requires no cut-off
switch. When energized, the shunt trip supplies +24Vdc power to the trip unit to power
the display.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
– 12 SPST012R 纬轩机电301.00 SPST012 纬轩机电328.00
24 24 SPST024R 纬轩机电301.00 SPST024 纬轩机电328.00
48 48 SPST048R 纬轩机电301.00 SPST048 纬轩机电328.00
120 125 SPST120R 纬轩机电301.00 SPST120 纬轩机电328.00
208 – SPST208R 纬轩机电301.00 SPST208 纬轩机电328.00
240 250 SPST240R 纬轩机电301.00 SPST240 纬轩机电328.00
480 – SPST480R1 纬轩机电301.00 SPST4801 纬轩机电328.00
600 – SPST600R1 纬轩机电301.00 SPST6001 纬轩机电328.00
1Kit contains externally mounted transformer.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
12 SPSTL012R 纬轩机电401.00 SPSTL012 纬轩机电428.00
24 24 SPSTL024R 纬轩机电401.00 SPSTL024 纬轩机电428.00
48 48 SPSTL048R 纬轩机电401.00 SPSTL048 纬轩机电428.00
120 125 SPSTL120R 纬轩机电401.00 SPSTL120 纬轩机电428.00
208 – SPSTL208R 纬轩机电401.00 SPSTL208 纬轩机电428.00
240 250 SPSTL240R 纬轩机电401.00 SPSTL240 纬轩机电428.00
480 – SPSTL480R1 纬轩机电401.00 SPSTL480 纬轩机电428.00
600 – SPSTL600R1 纬轩机电401.00 SPSTL600 纬轩机电428.00
1Kit contains externally mounted transformer.
Shunt Trip Module
Shunt Trip with Lockout Module
The shunt trip with lockout is identical to the regular shunt trip, but when energized, it
will also prevent closure of an "open" breaker by mechanically blocking both manual and
electrical closing. When energized, the closing springs will not discharge, the movable
contacts will not move; the contacts are "kiss free."
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-23
to change without notice
Undervoltage Release Module
The undervoltage release is an electronic module used to open the circuit breaker when
the monitored voltage drops below 35-60% of its rated value. The undervoltage release
"resets" when the monitored voltage is re-established allowing the circuit breaker to reclose
(the sealing voltage of the UVR is 60-85% of its rated voltage).
An undervoltage release trip operation is produced by the MicroVersaTrip? Plus unit in
response to a signal from the undervoltage release module. This allows the trip unit to
record, display, distinguish and communicate (in MicroVersaTrip? PM trip units) that the
breaker opening event was due to undervoltage release. Operation of the undervoltage
release module will prevent breaker contact closure, i.e. "kiss-free" operation. When
energized, the undervoltage release supplies +24 Vdc power to the trip unit to power
the display.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
24 – SPUV024ACR 纬轩机电301.00 SPUV024AC 纬轩机电328.00
48 – SPUV048ACR 纬轩机电301.00 SPUV048AC 纬轩机电328.00
120 – SPUV120ACR 纬轩机电301.00 SPUV120AC 纬轩机电328.00
208 – SPUV208ACR 纬轩机电301.00 SPUV208AC 纬轩机电328.00
240 – SPUV240ACR 纬轩机电301.00 SPUV240AC 纬轩机电328.00
480 – SPUV480ACR1 纬轩机电301.00 SPUV480AC1 纬轩机电328.00
600 – SPUV600ACR1 纬轩机电301.00 SPUV600AC1 纬轩机电328.00
– 12 SPUV012DCR 纬轩机电301.00 SPUV012DC 纬轩机电328.00
– 24 SPUV024DCR 纬轩机电301.00 SPUV024DC 纬轩机电328.00
– 48 SPUV048DCR 纬轩机电301.00 SPUV048DC 纬轩机电328.00
– 125 SPUV125DCR 纬轩机电301.00 SPUV125DC 纬轩机电328.00
– 250 SPUV250DCR 纬轩机电301.00 SPUV250DC 纬轩机电328.00
1Kit contains externally mounted transformer.
Undervoltage Release Module
Bell Alarm (Alarm Only)
The bell alarm module is used to signal breaker "tripped" status to other accessories
(e.g., external alarm devices, indicating lights, relays, or logic circuits) for remote indication
and interlocking functions. The bell alarm response is configurable by means of
rear-mounted DIP switches on the trip unit. The bell alarm can be made to operate in
response to an overcurrent (including ground fault) or protective relay trip and/or a
shunt trip operation, and/or operation of the undervoltage release module. It is not
actuated as a result of normal breaker "ON/OFF" operation.
This module provides a visual, mechanical pop-out target, which protrudes through the
face of the circuit breaker door when it operates. The bell alarm may be reset manually
by depressing the mechanical target, or automatically by closing the breaker.
The bell alarm is provided with one SPDT switch with control power duty contacts as
shown in the auxiliary switch accessories.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
240 125-250 SPBAA240R 纬轩机电124.00 SPBAA240 纬轩机电135.00
600 125-250 SPBAA600R1 纬轩机电124.00 SPBAA6002 纬轩机电135.00
2600 Vac module not UL Listed.
Bell (Alarm Only)
List Price
Description Product Number GO-245B
Time Delay Module
(0.1 to 1.0 second delay) SPUVTD 纬轩机电430.00
Time Delay Module for UVR
The time delay module prevents nuisance tripping due to momentary loss of voltage.
The module has 120 Vac input and 125 Vdc output and must be used with the 125 Vdc UVR.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-24 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Bell Alarm With Lockout
The bell alarm with lockout module combines both the bell alarm and a manual lockout
function. The bell alarm switch operates identically to the standard bell alarm module,
except that the mechanical pop-out target must be manually reset before the breaker
can be closed.
Operation of the bell alarm with lockout module can be independently set by means
of setting the DIP switches at the rear of the trip unit. Current rating of the single SPDT
switch is identical to the auxiliary switch accessories.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
240 125-250 SPBAL240R 纬轩机电124.00 SPBAL240 纬轩机电135.00
600 125-250 SPBAL600R1 纬轩机电124.00 SPBAL6001 纬轩机电135.00
1600 Vac module not UL Listed. Bell Alarm with Mechanical Reset Lockout
Auxiliary Switch
An auxiliary switch signals the circuit breaker’s primary contact position (i.e., OPEN or
CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables
the user to provide remote indication, interlocking or control operations as a function of
breaker primary contact position. The auxiliary switch operation is independent of the
method by which the breaker is opened or closed. The auxiliary switch does not distinguish
between a "tripped" or "open" condition. The auxiliary switch contacts follow the
main breaker contacts on opening and precede them on closing.
Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control
power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module
comes pre-wired to its own terminal board, which mounts with one screw to the left of
the breaker. A special accessory, available for draw out breakers, comes pre-wired to the
breaker secondary disconnect. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125
Vdc and 1/4A at 250 Vdc.
Auxiliary Switches for Stationary Breakers
No. of SPDT
Ratings Ratings Switch Elements Field Installable List Price Factory Installed List Price
Vac Vdc (Contacts) Product Number GO-245B Product Number GO-245B
240 125-250 4 SPAS240AB4R 纬轩机电268.00 SPAS240AB4 纬轩机电293.00
240 125-250 8 SPAS240AB8R 纬轩机电564.00 SPAS240AB8 纬轩机电616.00
240 125-250 12 SPAS240AB12R 纬轩机电651.00 SPAS240AB12 纬轩机电710.00
600 125-250 4 SPAS600AB4R1 纬轩机电268.00 SPAS600AB41 纬轩机电293.00
600 125-250 8 SPAS600AB8R1 纬轩机电564.00 SPAS600AB81 纬轩机电616.00
1600 Vac module not UL Listed.
Auxiliary Switch with
Pre-wired Secondary Terminals
for Stationary Breaker
Auxiliary Switch with
Pre-wired Secondary Terminals
for Draw-out Breaker
Auxiliary Switches for Draw-out Breakers
No. of SPDT
Ratings Ratings Switch Elements Field Installable List Price Factory Installed List Price
Vac Vdc (Contacts) Product Number GO-245B Product Number GO-245B
240 125-250 4 SPAS240AB4DR 纬轩机电551.00 SPAS240AB4D 纬轩机电576.00
240 125-250 8 SPAS240AB8DR 纬轩机电847.00 SPAS240AB8D 纬轩机电899.00
240 125-250 12 SPAS240AB12DR 纬轩机电934.00 SPAS240AB12D 纬轩机电993.00
600 125-250 4 SPAS600AB4DR1 纬轩机电551.00 SPAS600AB4D1 纬轩机电576.00
600 125-250 8 SPAS600AB8DR1 纬轩机电847.00 SPAS600AB8D1 纬轩机电899.00
1600 Vac module not UL Listed.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-25
to change without notice
Mechanical Operations Counter
The mechanical operations counter is mounted behind the front cover of the breaker. It
is viewable through a rectangular knockout window opening in the breaker cover. It is a
five-digit, non-resettable counter, which is actuated each time the breaker is opened by
any means.
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPCOUNTERR 纬轩机电100.00 SPCOUNTER 纬轩机电125.00
Hidden "ON" Button
The hidden "ON" button is assembled to the mechanism behind an unlabeled, false
pushbutton. Manual closing of the breaker can only be performed by means of a small
diameter rod. This accessory is used to limit access to the manual "ON" control to
authorized personnel.
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPPBNONR 纬轩机电64.00 SPPBNON 纬轩机电64.00
Maintenance/Repair Parts
Description Product Number List Price GO Schedule
Top Cover and Rating Labels SPBII-REPLACE_COVER1 纬轩机电600.00 148C
Replacement MVT Door 10054335P1 纬轩机电20.00 148G
Replacement Powerplus Door 10054335P2 纬轩机电16.00 148G
Stop Block Kit w/Installation Tool SPBUMPERKIT 纬轩机电175.00 148C
Stop Block Kit (no tools) SPBUMPNTKIT 纬轩机电90.00 148C
1Special handling and order entry required to preserve UL Listing of breaker.
Contact Post Sale Service for additional details of special process.
Limited Access Pushbutton Cover
This accessory limits access to "ON/OFF" control of a breaker to authorized personnel.
The pushbutton cover accessory consists of transparent hinged covers that can be individually
sealed to the limited access assembly. Both the "ON" and "OFF" buttons can be
pilot drilled to allow use of a 1/8" rod to operate either one or both pushbuttons.
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPPBCOVERR 纬轩机电80.00 SPPBCOVER 纬轩机电90.00
Mechanical Operations Counter
Breaker with limited access pushbutton
cover assembly installed
Activating the breaker closing
mechanism through the hole in the
Hidden “ON” Button
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-26 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Key Interlock Provisions
The key interlock provision enables the user to mount a one- to four-cylinder, narrowfaced,
Kirk-type FN or Superior customer-supplied lock on the face of the breaker. This
accessory provides mounting for key interlocks that are furnished by the customer. The
key interlock provision works in conjunction with the padlock provision. The key interlock
extends a lever through the padlock hasp when the key is turned to the key removal or
bolt extended position. Additionally, the accessory provides a hasp for mounting three
padlocks with 1/4" to 3/8" diameter shanks.
Padlock Provisions (Standard)
Padlocking provisions are standard on all Power Break? II circuit breakers. When the
breaker is in the open position, and the padlock hasp is raised at least 1/4", the breaker
cannot be closed mechanically or electrically. The hasp accepts up to three padlocks
with 1/4" to 3/8" diameter shanks.
Walking Beam Interlocks—Stationary Breakers Only
Walking beam interlocks are mechanical devices used to prevent two adjacent circuit
breakers from both being in the "ON" or closed position at the same time. However, both
breakers can be in the "OFF" or open position.
Door Interlock
The door interlock provides interlocking of the circuit breaker compartment’s hinged
door so that the breaker must be in the "OFF" position before the door can be opened.
The door interlock is defeatable with a small tool to allow authorized access.
Circuit Breaker List Price
Envelope Size (Amperes) Product Number GO-245B
800, 1600 and 2000 SPWB20 纬轩机电1228.00
3000 SPWB30 纬轩机电1228.00
4000 SPWB40 纬轩机电1228.00
Product Numbers, Key Interlock Provisions
Circuit Breaker Number of Field Installed List Price Factory Installed List Price
Envelope Size (Amps) Key Locks Product Number GO-245B Product Number GO-245B
All 1 to 4 SPK4R 纬轩机电355.00 SPK4 纬轩机电426.00
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPDILR 纬轩机电173.00 SPDIL 纬轩机电208.00
Key Interlock Kit (lock not included)
Door Interlock
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
15-150A Circuit Breakers.....................................................................1-8
70-250A Circuit Breakers.....................................................................1-9
125-600A Circuit Breakers ..................................................................1-9
300-1200A Circuit Breakers.............................................................1-10
Rating Plugs.............................................................................................1-11
Power Management System Accessories
For Spectra? RMS Circuit Breakers ...............................................1-12
Record Plus? FC 100 Accessories.......................................................1-17
Record Plus? FE 250 Accessories .......................................................1-18
Insulated Case Circuit Breakers
History/Timeline .........................................................................................1-19
Power Break? II Circuit Breaker Accessories
Enhanced MicoVersaTrip?, Rating Plug Selection .................1-20
Stationary & Draw-out Breaker Accessories ...........................1-21
Stationary Breaker Mounting Kits.................................................1-27
Neutral Current Sensors & POWER LEADER Accessories ..1-29
Draw-out Breakers and Accessories...........................................1-30
Disconnect Switches & Operating Mechanisms
High-Pressure Contact Switch
With Internal Ground Fault Devices.............................................1-32
Accessories..............................................................................................1-33
1
This catalog contains replacement parts, retrofits, accessories,
and older generation products. For current generation products,
please see the GE BuyLog? or Control Catalog.
Components: Parts
1
1-2 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Molded Case Circuit Breakers
History/Timeline
GE Molded Case Circuit Breakers History/Timeline
1950s CORE (Q-Line, TEY, THED, THFK, THJK, THKM)
Thermal Magnetic
1970s CORE (TJLS, TKLS, TJL4V, TKL4V)
Electronic Trip (VersaTrip, SelecTrip, RMS9, MVT)
1990s Spectra? SE, SF, SG, SK
Electronic Trip (S1, MVT+, MVTpm)
2005 Record Plus? (FB)
Thermal Magnetic
2007 Record Plus? (FE, FG)
Electronic Trip (SMR1, SMR2)
This catalog contains replacement parts, retrofits, accessories,
and older generation products. For current generation products,
please see the GE BuyLog? or Control Catalog.
Components: Parts
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-3
to change without notice
Auxiliary Switches
Unless otherwise noted switch is SPDT rated 6 amperes at rated ac voltage, 1/2 amperes at 125 Vdc, 1/4 amperes at 250 Vdc.
Control Voltage 240 Vac, 250 Vdc Maximum Control Voltage 600 Vac, 250 Vdc Maximum
UL Listed When Factory Installed Suffix1 Not UL Listed Suffix1
Number of Add to Base Product Add to Base Product
SPDT Switch Base Number for Factory List Price Base Number for Factory List Price
Breaker Type Elements Number Installation12 GO-135LG Number Installation12 GO-135LG
TQB, THQB, THHQB, TXQB, TQL, 13 TQAS2A12, 4 5 纬轩机电64.5011 – ––
THQL, THHQL, TXQL
TQC, THQC, THHQC, TXQC 13 TQCAS2A12, 4 5 纬轩机电77.5011 – ––
TQD, THQD 1 TQDAS2AB1RS N/A 纬轩机电148.006 – –
TEB, TEC, TB1 1 TEDAS2AB1R,L7,8 S 纬轩机电148.0011 TEDAS6AB1R,L7, 8 S 纬轩机电179.0011
TED, THED,THLC18 2 TEDAS2AB2R,L7,8 S 纬轩机电295.0011 TEDAS6AB2R,L7, 8 S 纬轩机电360.0011
TFC, TFJ, TFK, THFK,9 1 TFKASA2AB110 RS or LS 纬轩机电148.00 TFKASA6AB110 RS 纬轩机电167.00
THLC2, THLC4, TLB2, TLB4 2 TFKASA2AB210 RS or LS 纬轩机电295.00 TFKASA6AB210 RS 纬轩机电360.00
1 TJKASA2AB1R,L S 纬轩机电148.00 TJKASA6AB1R,L S 纬轩机电179.00
2 TJKASA2AB2R,L S 纬轩机电295.00 TJKASA6AB2R,L S 纬轩机电360.00 TJC, TJD, TJJ, TJK, THJK 3 TJKASA2AB3R,L S 纬轩机电439.00 TJKASA6AB3R,L S 纬轩机电530.00
4 TJKASA2AB4R,L S 纬轩机电598.00 TJKASA6AB4R,L S 纬轩机电712.00
1 TB4ASA2AB1R,L S 纬轩机电148.00 TB4ASA6AB1R,L S 纬轩机电179.00
2 TB4ASA2AB2R,L S 纬轩机电295.00 TB4ASA6AB2R,L S 纬轩机电360.00 TB4, TBC4 3 TB4ASA2AB3R,L S 纬轩机电439.00 TB4ASA6AB3R,L S 纬轩机电530.00
4 TB4ASA2AB4R,L S 纬轩机电598.00 TB4ASA6AB4R,L S 纬轩机电712.00
1 TKMAAS2AB1 RS or LS 纬轩机电148.00 TKMAAS6AB1 RS or LS 纬轩机电179.00
TKM, THKM, TKC, TB6, 2 TKMAAS2AB2 RS or LS 纬轩机电295.00 TKMAAS6AB2 RS or LS 纬轩机电360.00
TB8, TBC6, TBC8 3 TKMAAS2AB3 RS or LS 纬轩机电439.00 TKMAAS6AB3 RS or LS 纬轩机电530.00
4 TKMAAS2AB4 RS or LS 纬轩机电598.00 TKMAAS6AB4 RS or LS 纬轩机电712.00
1"S" suffix for wires out the side of breaker. For lead exit from back of breaker, replace suffix "S" with "B" and multiply list price by 1.25. "B" suffix not UL listed. Not available
with leads out the back for "Q-Line", or 2 element auxiliary switches used on TFG, TFJ, TFK, THFK, THLC2, THLC4, TLB2, and TLB4.
2Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers.
3Switch is SPST. Operates like "A" side of an "AB" contact and is rated six amperes at 120 Vac and three amperes at 24 Vac.
4Accessories mounted in a one-inch frame and increase overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Must be factory
installed. Maximum total breaker width is four poles.
5To order, specify both the accessory and breaker product number, e.g. THQL2130, TQASA1 identifies a 30 ampere, 2-pole plug-in breaker with a factory installed SPST auxiliary
switch.
6GO-135F.
7Auxiliary switch mounts in right pole only on two-pole TEB, TED breakers. (Factory installed only.)
8Not available with “B” suffix–leads out back.
9Changes circuit breaker interrupting capacity to 10kAIC, 600 Vac; 22 kAIC, 240 and 480 Vac.
10UL listed for field installation.
11GO-135B.
12For factory installation, contact Customer Service Center.
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
1
Components: Parts
1
1-4 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Shunt Trip
Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number List Price
Breaker Type Vac Vdc for Field Replacement for Factory Installation GO-135B
TQB, THQB, THHQB, TXQB, 120-240 TQSTA14,5,6 9 纬轩机电95.50
TQL, THQL, THHQL, TXQL 12 TQSTA74,5,6 9 纬轩机电95.50
24-48 TQSTA84,5,6 9 纬轩机电95.50
120 TQDST17,8 9 纬轩机电178.0012
240 TQDST28 9 纬轩机电178.0012
TQD, THQD 12 TQDST78 9 纬轩机电178.0012
24 TQDST88 9 纬轩机电178.0012
120 TEDST12 RS or LS7,11 纬轩机电363.00
240 TEDST12 RS or LS7,11 纬轩机电363.00
480 TEDST13 RS or LS7,11 纬轩机电363.00
TEB, TEC, TB1-B,10 600 TEDST13 RS or LS7,11 纬轩机电363.00
TED, THED, THLC1 12 TEDST7 RS or LS7,11 纬轩机电363.00
24 TEDST8 RS or LS7,11 纬轩机电363.00
48 TEDST9 RS or LS7,11 纬轩机电363.00
125 TEDST12 RS or LS7,11 纬轩机电363.00
250 TEDST11 RS or LS7,11 纬轩机电363.00
120 TFKSTA121 RS or LS 纬轩机电363.0013
240 TFKSTA121 RS or LS 纬轩机电363.0013
480 TFKSTA131 RS or LS 纬轩机电363.0013
TFC, TFJ, TFK, THFK, THLC2, 600 TFKSTA131 RS or LS 纬轩机电363.0013
THLC4, TLB2, TLB4 12 TFKSTA71 RS or LS 纬轩机电363.0013
24 TFKSTA81 RS or LS 纬轩机电363.0013
48 TFKSTA91 RS or LS 纬轩机电363.0013
125 TFKSTA121 RS or LS 纬轩机电363.0013
250 TFKSTA111 RS or LS 纬轩机电363.0013
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number
192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed.
Not available with leads out the back on "Q-Line." For factory installation, contact Customer Service Center.
4Mounts on a one-inch frame and increases overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Maximum total breaker width is
4-pole. Must be factory installed.
5Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers.
6TQST shunt trips not available on breakers over 100 A.
7Not available with “B” suffix–leads out back.
8Must be factory installed, right pole only.
9To order, specify both the accessory and breaker product number =, e.g. THQL2130, TQST1 identifies a 30 A, 2-pole plug-in breaker with a factory installed 120 Vac shunt
trip.
10For TB1 with bolt-on limiters.
11Mounts in the right pole only on 2-pole TEB, TED breakers.
12GO-135F.
13GO-135LG.
How to Order
For field replacement, order base number only. For factory installation, contact Customer
Service Center and order base number plus appropriate suffix. For a nonautomatic breaker
(molded case switch) a dummy trip is required when installing either a shunt trip or UVR.
Shunt Trip
Remote Tripping – Trips breaker by remote control. Trip coil de-energized when breaker
opens. Device meets UL requirements for service to ground fault system.
Undervoltage Release
Undervoltage release automatically trips breaker when applied coil voltage drops to 30
to 70 percent of rated value. Time-delay unit prevent nuisance tripping due to
momentary loss of voltage. Separate externally mounted unit has 120 Vac input and 125
Vdc output. Used in conjunction with 125 Vdc undervoltage release which must be
ordered separately. Product number SPUVTD for adjustable delay .1 to 1.0 seconds. List
Price 纬轩机电430.00 GO-245B.
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-5
to change without notice
Shunt Trip (continued)
Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number List Price
Breaker Type Vac Vdc for Field Replacement for Factory Installation GO-135LG
120 TJKSTA12R,L S 纬轩机电363.00
240 TJKSTA12R,L S 纬轩机电363.00
480 TJKSTA13R,L S 纬轩机电363.00
600 TJKSTA13R,L S 纬轩机电363.00
TJC, TJD, TJJ, TJK, THJK 12 TJKSTA7R,L S 纬轩机电363.00
24 TJKSTA8R,L S 纬轩机电363.00
48 TJKSTA9R,L S 纬轩机电363.00
125 TJKSTA12R,L S 纬轩机电363.00
250 TJKSTA11R,L S 纬轩机电363.00
120 TB4STA12R,L5 纬轩机电363.00
240 TB4STA12R,L5 纬轩机电363.00
480 TB4STA13R,L5 纬轩机电363.00
600 TB4STA13R,L5 纬轩机电363.00
TB4, TBC4 12 TB4STA7R,L5 纬轩机电363.00
24 TB4STA8R,L5 纬轩机电363.00
48 TB4STA9R,L5 纬轩机电363.00
125 TB4STA12R,L5 纬轩机电363.00
250 TB4STA11R,L5 纬轩机电363.00
120 TKMASTA12R,L S 纬轩机电363.00
240 TKMASTA12R,L S 纬轩机电363.00
480 TKMASTA13R,L S 纬轩机电363.00
600 TKMASTA13R,L S 纬轩机电363.00 TKC, TKM, THKM, TB6, 12 TKMASTA7R,L S 纬轩机电363.00 TB8, TBC6, TBC84 24 TKMASTA8R,L S 纬轩机电363.00
48 TKMASTA9R,L S 纬轩机电363.00
125 TKMASTA12R,L S 纬轩机电363.00
250 TKMASTA11R,L S 纬轩机电363.00
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number
192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed.
Not available with leads out the back on "Q-Line." For factory installation, contact Customer Service Center.
4Not UL listed.
5Not available for factory installation.
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
Components: Parts
1
Components: Parts
1
1-6 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Undervoltage Release
Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number List Price
Breaker Type Vac Vdc for Field Replacement for Factory Installation GO-135LG
120 TEDUV1 RS8 纬轩机电363.007
240 TEDUV2 RS8 纬轩机电363.007
480 TEDUV4 RS8 纬轩机电363.007
TEB, TEC, TB1-B5 600 TEDUV6 RS8 纬轩机电363.007
TED, THED, THLC1 12 TEDUV7 RS8 纬轩机电363.007
24 TEDUV8 RS8 纬轩机电363.007
48 TEDUV9 RS8 纬轩机电363.007
125 TEDUV10 RS8 纬轩机电363.007
250 TEDUV11 RS8 纬轩机电363.007
120 TFKUVA11 RS or LS 纬轩机电363.00
240 TFKUVA2 RS or LS 纬轩机电363.00
480 TFKUVA4 RS or LS 纬轩机电363.00
600 TFKUVA6 RS or LS 纬轩机电363.00 TFC, TFJ, TFK, THFK, THLC2, 12 TFKUVA7 RS or LS 纬轩机电363.00 THLC4, TLB2, TLB4 24 TFKUVA8 RS or LS 纬轩机电363.00
48 TFKUVA9 RS or LS 纬轩机电363.00
125 TFKUVA10 RS or LS 纬轩机电363.00
250 TDKUVA11 RS or LS 纬轩机电363.00
120 TJUV1R S 纬轩机电363.00
240 TJUV2R S 纬轩机电363.00
480 TJUV4R S 纬轩机电363.00
600 TJUV6R S 纬轩机电363.00
TJC, TJD, TJJ, TJK, THJK 12 TJUV7R S 纬轩机电363.00
24 TJUV8R S 纬轩机电363.00
48 TJUV9R S 纬轩机电363.00
125 TJUV10R S 纬轩机电363.00
250 TJUV11R S 纬轩机电363.00
120 TKUV1R S 纬轩机电363.00
240 TKUV2R S 纬轩机电363.00
480 TKUV4R S 纬轩机电363.00
TKC, TKM, THKM, TB6, 600 TKUV6R S 纬轩机电363.00
TB8, TBC6, TBC86 12 TKUV7R S 纬轩机电363.00
24 TKUV8R S 纬轩机电363.00
48 TKUV9R S 纬轩机电363.00
125 TKUV10R S 纬轩机电363.00
250 TKUV11R S 纬轩机电363.00
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1 for 120 Vac UVRs on all other breaker lines, order Product Number
192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed.
Not available with leads out the back on "Q-Line." For factory installation, contact Customer Service Center.
4For TB1 with bolt-on limiters.
5Not available with “B” suffix – leads out back.
6Not UL listed.
7GO-135B.
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-7
to change without notice
Dummy Trip1
List Price
Breaker Type Product Number GO-135LG
E150 Internal accessories for these noninterchangeable No FJ225 breakers require factory-installed dummy trips. Charge JJ400 Automatically supplied when accessories are ordered.
FK225 TFKYT2 (two-pole) 纬轩机电148.00
FK225 TFKYT3 (three-pole) 纬轩机电208.00
JK400 TJKYT3 (two-pole, three-pole) 纬轩机电212.00
JK600 TJKYT36 (two-pole, three-pole) 纬轩机电212.00
KM800 TKMAYT3 (two-pole, three-pole) 纬轩机电261.00
KM1200 TKMA3YT12 (two-pole, three-pole) 纬轩机电424.00
1Not UL listed when field installed.
2Add "B" suffix for leads exit from back of breaker; for price, multiply List Price
by 1.25. For factory installation, contact Customer Service Center.
3Not available with “B” suffix – leads out back.
4Not available for two-pole TEB, TED. Order TEDBAR.
5Changes circuit breaker interrupting capacity to: 10kA @ 600 Vac, 22kA @ 480 Vac,
22kA @ 240 Vac, for TFC, TFJ, TFK and THFK only.
6UL listed for field installation.
7Mounts in center pole with leads out left side.
8GO-135B
Bell Alarm Switches
Product Number2
Breaker UL Listed When Factory Installed List Price
Type Base No. Suffix GO-135LG
TEB, TEC, TB1 TEDBAR or S 纬轩机电154.008
TED, THED, THLC1 TEDBAL3,4 纬轩机电154.008
TFC, TFJ, TFK, THFK, TFKBAAR5,6 S 纬轩机电154.00 THLC2, THLC4, TLB4
TJC, TJJ, TJK, THJK TJKBAAL7 S 纬轩机电156.00 TB4, TBC4, TJD
TKC, TKM, THKM, TKMABAAL7 S 纬轩机电141.00 TB6, TBC6, TBC8, TB8
Blown Fuse Detector-Three-Coil Shunt Trip
Product Number2
Breaker UL Listed When Factory Installed List Price
Type Base No. Suffix GO-135LG
TED, THED, TEC3 TEDST316 RS 纬轩机电672.008
TFJ, TJK, THFK, TFC TFKBFD316 LS or RS 纬轩机电672.00
TJJ, TJK, THJK, TJD, TJC TJKST316 LS 纬轩机电672.00
TKM, THKM, TKC TKMAST316 LS 纬轩机电672.00
Molded Case Circuit Breakers
Internal Accessories
Internally Mounted Signaling and Controlling Functions
Components: Parts
1
1-8 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SED, SEH; 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adj. Inst. 18kA 25kA
Ampere Trip Range Amps Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Number GO-135S Number GO-135S Number GO-135S Range
15 43 182 SRPE30A15 纬轩机电106.00
20 58 254 SRPE30A20 纬轩机电106.00 30 SEDA24AT0030 纬轩机电214.00 SEHA24AT0030 纬轩机电530.00 25 73 332 SRPE30A25 纬轩机电106.00
30 87 415 SRPE30A30 纬轩机电106.00
40 118 501 SRPE60A40 纬轩机电106.00
50 148 637 SRPE60A50 纬轩机电106.00 60 SEDA24AT0060 纬轩机电214.00 SEHA24AT0060 纬轩机电530.00 12-3/0 Cu 60 178 777 SRPE60A60 纬轩机电106.00 TCAL18 纬轩机电3.00 12-3/0 Al 70 206 863 SRPE100A70 纬轩机电106.00
80 236 999 SRPE100A80 纬轩机电106.00 100 SEDA24AT0100 纬轩机电312.00 SEHA24AT0100 纬轩机电634.00 90 267 1138 SRPE100A90 纬轩机电106.00
100 297 1280 SRPE100A100 纬轩机电106.00
110 328 1426 SRPE150A110 纬轩机电106.00
125 374 1640 SRPE150A125 纬轩机电106.00 150 SEDA24AT0150 纬轩机电837.00 SEHA24AT0150 纬轩机电1427.00
150 450 1991 SRPE150A150 纬轩机电106.00
SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SEL, SEP2; 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac UL 489 IC @480 Vac
Adj. Inst. 65kA 100kA
Ampere Trip Range Amps Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Number GO-135S Number GO-135S Number GO-135S Range
15 43 182 SRPE30A15 纬轩机电106.00
20 58 254 SRPE30A20 纬轩机电106.00 30 SELA24AT0030 纬轩机电549.00 SEPA24AT0030 纬轩机电895.00 25 73 332 SRPE30A25 纬轩机电106.00
30 87 415 SRPE30A30 纬轩机电106.00
40 118 501 SRPE60A40 纬轩机电106.00
50 148 637 SRPE60A50 纬轩机电106.00 60 SELA24AT0060 纬轩机电549.00 SEPA24AT0060 纬轩机电895.00 12-3/0 Cu 60 178 777 SRPE60A60 纬轩机电106.00 TCAL18 纬轩机电3.00
70 206 863 SRPE100A70 纬轩机电106.00 12-3/0 Al
80 236 999 SRPE100A80 纬轩机电106.00 100 SELA24AT0100 纬轩机电744.00 SEPA24AT0100 纬轩机电1179.00 90 267 1138 SRPE100A90 纬轩机电106.00
100 297 1280 SRPE100A100 纬轩机电106.00
110 328 1426 SRPE150A110 纬轩机电106.00
125 374 1640 SRPE150A125 纬轩机电106.00 150 SELA24AT0150 纬轩机电1808.00 SEPA24AT0150 纬轩机电2777.00
150 450 1991 SRPE150A150 纬轩机电106.00
2SEL, SEP UL current limiting.
Note: All Spectra? breakers UL listed as HACR type.
All Spectra? breakers marked CE.
Product Number Structure
S E D A 2 4 A T 0030
Frame Rating Interruption Continuous Voltage Trip Trip Sensor
Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra? E = 150 D = 18 kA A = Standard 2 = 2 poles 4 = 480V A = RMS1 T = LSI1 0030
H = 25 kA 3 = 3 poles 6 = 600V 0060
L = 65 kA 0100
P = 100 kA 0150
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
Molded Case Circuit Breakers
Industrial Circuit Breaker Accessories
15-150A Circuit Breakers, Electronic Trip, Spectra? RMS, SE150 Line Circuit Breakers
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-9
to change without notice
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGD, SGH; UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
Adjustable
UL 489 IC @480 Vac UL 489 IC @480 Vac
Instantaneous 65kA (240 Vac) 35kA
Ampere Trip Ampere Range Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Poles Number GO-135S Number GO-135S Number GO-135S Range
125 380 1275 SRPG400A125 纬轩机电106.00 2-pole lug kit 150 455 1530 SRPG400A150 纬轩机电106.00 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 纬轩机电106.00 2 SGDA22AT04004 纬轩机电1540.00 SGHA26AT0400 纬轩机电1959.00 TCLK2655 纬轩机电28.00 or
200 605 2040 SRPG400A200 纬轩机电106.00 (1) 8-600 Cu
225 680 2295 SRPG400A225 纬轩机电106.00 400
250 755 2550 SRPG400A250 纬轩机电106.00 3-pole lug kit 300 905 3060 SRPG400A300 纬轩机电106.00 3 SGDA32AT04004 纬轩机电1860.00 SGHA36AT0400 纬轩机电2383.00 (2) 2/0-500 Al
350 1060 3570 SRPG400A350 纬轩机电106.00 TCLK3655 纬轩机电42.00 or
400 1210 4080 SRPG400A400 纬轩机电106.00 (1) 8-600 Al
4Rated 240 Vac max.
5Order one kit for either line or load end; two kits required for both.
Note: All Spectra? breakers UL listed as HACR type. All Spectra? breakers marked CE.
125-600A Circuit Breakers, Electronic Trip, Spectra? RMS, SG600 Digital, Solid-State Spectra? RMS Breakers
70-250A Circuit Breakers, Electronic Trip, Spectra? RMS, SF250 Line Circuit Breakers
SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SFH; 2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
Adjustable Instantaneous
UL 489 IC @480 Vac
Trip Ampere Range
35kA
Ampere Product List Price Current Product List Price Product List Price Wire
Rating Low Hi gh Number GO-135S Sensor Number GO-135S Number GO-135S Range
70 205 700 SRPF250A70 纬轩机电106.00
90 265 900 SRPF250A90 纬轩机电106.00
100 295 1000 SRPF250A100 纬轩机电106.00
110 325 1100 SRPF250A110 纬轩机电106.00 8-350 Cu 125 370 1250 SRPF250A125 纬轩机电106.00 250 SFHA24AT0250 纬轩机电1134.00 TCAL29 纬轩机电8.00 150 440 1500 SRPF250A150 纬轩机电106.00 8-350 Al
175 515 1750 SRPF250A175 纬轩机电106.00
200 590 2000 SRPF250A200 纬轩机电106.00
225 665 2250 SRPF250A225 纬轩机电106.00
250 736 2500 SRPF250A250 纬轩机电106.00
Molded Case Circuit Breakers
Industrial Circuit Breaker Accessories
Product Number Structure
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
S F H A 2 4 A T 0250
Frame Rating Interruption Continuous Voltage Trip Trip Sensor
Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra? F = 250 H = 35 kA A = Standard 2 = 2 poles 4 = 480V A = RMS1 T = LSI1 0250
L = 65 kA 3 = 3 poles 6 = 600V
P = 100 kA
Product Number Structure
S G D A 2 2 A T 0400
Frame Rating Interruption Continuous Voltage Trip Trip Sensor
Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra? G = 600 D = 65 kA2 A = Standard 2 = 2 poles 2 = 240V A = RMS1 T = LSI3 0400
H = 35 kA H = 100% 3 = 3 poles 6 = 600V 0600
L = 65 kA L = 100%
P = 100 kA P = 100% 2 SGD rated 65kA at 240V.
3Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
Components: Parts
1
1-10 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
Adjustable
UL 489 IC @480 Vac UL 489 IC @480 Vac
Instantaneous 50kA 65kA
Ampere Trip Ampere Range Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Poles Number GO-135S Number GO-135S Number GO-135S Range
300 940 3015 SRPK800A300 纬轩机电106.00
400 1255 4015 SRPK800A400 纬轩机电106.00 2 SKHA26AT0800 纬轩机电3377.00 SKLA26AT0800 纬轩机电4301.00 (3) 3/0-500 Cu
500 1570 5020 SRPK800A500 纬轩机电106.00 800 TCAL81 纬轩机电47.00 600 1875 6195 SRPK800A600 纬轩机电106.00
700 2155 7420 SRPK800A700 纬轩机电106.00 3 SKHA36AT0800 纬轩机电4323.00 SKLA36AT0800 纬轩机电5234.00 (3) 3/0-500 Al 800 2440 8705 SRPK800A800 纬轩机电106.00
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max.
Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
Adjustable
UL 489 IC @480 Vac UL 489 IC @480 Vac
Instantaneous 50kA 65kA
Ampere Trip Ampere Range Product List Price Current Product List Price Product List Price Product List Price Wire
Rating Low High Number GO-135S Sensor Poles Number GO-135S Number GO-135S Number GO-135S Range
600 1825 6110 SRPK1200A600 纬轩机电106.00
700 2125 7125 SRPK1200A700 纬轩机电106.00 2 SKHA26AT1200 纬轩机电7057.00 SKLA26AT1200 纬轩机电7958.00 (4) 250-500 Cu
800 2430 8145 SRPK1200A800 纬轩机电106.00 1200 TCAL125 纬轩机电76.00 900 2735 9160 SRPK1200A900 纬轩机电106.00
1000 3040 10180 SRPK1200A1000 纬轩机电106.00 3 SKHA36AT1200 纬轩机电7679.00 SKLA36AT1200 纬轩机电8586.00 (4) 250-500 Al 1200 3650 12215 SRPK1200A1200 纬轩机电106.00
Note: All Spectra? breakers UL listed as HACR type.
All Spectra? breakers marked CE.
Molded Case Circuit Breakers
Industrial Circuit Breaker Accessories
Product Number Structure
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
S K H A 2 6 A T 0800
Frame Rating Interruption Continuous Voltage Trip Trip Sensor
Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra? K = 1200 H = 50 kA A = Standard 2 = 2 poles 6 = 600V A = RMS1 T = LSI1 0800
L = 65 kA H = 100% 3 = 3 poles 1200
P = 100 kA L = 100%
P = 100%
300-1200A Circuit Breakers, Electronic Trip, Spectra? RMS
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-11
to change without notice
MicroVersaTrip? Plus and PM Rating Plug Selection —
All Plugs List Price 纬轩机电106.00, GO-135S
Circuit Breaker Sensor Rating Plug Rating Plug
Frame Rating Rating (Amperes) Product No.
150 60 SRPG150B60
80 SRPG150B80
100 SRPG150B100
125 SRPG150B125
150 SRPG150B150
400 150 SRPG400B150
200 SRPG400B200
SGHB, SGHH, SGLB, 225 SRPG400B225
SGLL, SGPB, SGPP 250 SRPG400B250
300 SRPG400B300
350 SRPG400B350
400 SRPG400B400
600 300 SRPG600B300
400 SRPG600B400
450 SRPG600B450
500 SRPG600B500
600 SRPG600B600
1MicroVersaTrip? PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 1-12 to 1-14.
Note: All Spectra? breakers UL listed as HACR type.
All Spectra? breakers marked CE.
Microversatrip? Plus and PM Rating Plug Selection —
All Plugs List Price 纬轩机电106.00, GO-135S
Circuit Breaker Sensor Rating Plug Rating Plug
Frame Rating Rating (Amperes) Product No.
300 SRPK800B300
400 SRPK800B400
800 500 SRPK800B500
600 SRPK800B600
SKHB, SKHH, SKLB, 700 SRPK800B700
SKLL, SKPB, SKPP 800 SRPK800B800
600 SRPK1200B600
700 SRPK1200B700
1200 800 SRPK1200B800
1000 SRPK1200B1000
1200 SRPK1200B12002
1Microversatrip? PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 1-12 to 1-14.
2Not suitable for use with 100% rated, 1000A breaker frame.
Note: All Spectra? breakers UL listed as HACR type.
All Spectra? breakers marked CE.
300-1200A Circuit Breakers, Electronic Trip, Spectra? RMS, SK1200 with MicroVersaTrip? Plus and PM1
60-600A Circuit Breakers, Electronic Trip, Spectra? RMS , with MicroVersaTrip? PM Trip Unit1
Molded Case Circuit Breakers
Industrial Circuit Breaker Accessories
Rating Plugs
Components: Parts
1
1-12 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Molded Case Circuit Breakers
Power Management System Accessories
Spectra? RMS Circuit Breakers with MicroVersaTrip? Plus and MicroVersaTrip? PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)
Required Accessories
Type Accessories
Standard –
Ground Fault Option with 3-phase, 4-wire Neutral Current Sensor and Terminal Block
MicroVersaTrip? Plus Trip Unit or 1-phase, 3-wire service or Neutral Current Sensor and Junction Box
Control Power Option Power Supply Plate or Voltage Module1 or Power Supply Assembly2
Power Supply Plate and Voltage Conditioner Plate or Voltage Module1
Standard or with Protective Relaying or Power Supply Assembly2 and Voltage Conditioner Assembly2
MicroVersaTrip? PM Trip Unit Junction Box, Cable Harness and Auxiliary Switch
Ground Fault Option with 3-phase, 4-wire Neutral Current Sensor
or 1-phase, 3-wire service
1For installation into GE Spectra? Series Switchboards only.
2Requires fuse protection and other components; refer to accessory detail for additional information.
Power Supply Plate
The Power Supply Plate is used to provide +24 Vdc control power to Spectra? RMS Molded
Case Circuit Breakers with MicroVersaTrip? PM or MicroVersaTrip? Plus trip systems via the
Distribution Cable System. The Power Supply Plate includes the Power Supply Assembly
(product number SPSAA) as an integral component and also includes fuse protection for AC
source input. Supplemental +24 Vdc input terminals are provided for backup control power
applications. Five versions are available. Not suitable for 400 Hz. List Price
Description Voltage Rating Product Number GO-135PM
The Power Supply Plate is rated 24 watts 120 Vac SPSA120 纬轩机电1215.00
(+24 Vdc at 1.0 amperes) and has the maximum 208 Vac SPSA208 纬轩机电1215.00
capacity to power a distribution Cable System 240 Vac SPSA240 纬轩机电1215.00
consisting of 20 breakers and has a maximum 480 Vac SPSA480 纬轩机电1215.00
system cable length of 40 feet. 600 Vac SPSA600 纬轩机电1215.00
Voltage Conditoner Plate
The Voltage Conditioner Plate is used to provide voltage sensing signals to Spectra?
RMS Molded Case Circuit Breakers with MicroVersaTrip? PM Trip Units via the Distribution
Cable System. The Voltage Conditioner Plate includes the Voltage Conditioner Assembly
(product number SVCAA) as an integral component and also includes fuse protection
for the AC source input terminals and three 1-VA high accuracy potential transformers.
The Voltage Conditioner Plate requires a control power source of +24 Vdc to operate properly
(the Power Supply Assembly or Power Supply Plate can provide this required input). The unit
also requires AC direct voltage inputs from the AC source. A GE POWER LEADER? network
(commnet) connection is provided. Seven versions are available. Not suitable for 400 Hz. List Price
Voltage Rating and Service Type Comments Product Number GO-135PM
120 Vac Wye system Phase to Neutral potential SVCA120Y 纬轩机电1000.00
208 Vac Wye system Phase to Phase potential SVCA208Y 纬轩机电1000.00
240 Vac Delta system Phase to Phase potential SVCA240D 纬轩机电1000.00
277 Vac Wye system Phase to Neutral potential SVCA277Y 纬轩机电1000.00
480 Vac Wye system Phase to Phase potential SVCA480Y 纬轩机电1000.00
480 Vac Delta system Phase to Phase potential SVCA480D 纬轩机电1000.00
600 Vac Delta system Phase to Phase potential SVCA600D 纬轩机电1000.00
Note: The Voltage Conditoner Plate has the maximum capacity to power a Distribution Cable System consisting of
20 breakers and has a maximum system cable length of 40 feet.
Distribution Cable Junction Box
The Distribution Cable Junction Box is a modular connector used to provide quick, easy and
reliable attachment of Spectra? RMS Molded Case Circuit Breakers with MicroVersaTrip? Plus
trip systems or MicroVersaTrip? PM trip systems to the Distribution Cable System. The Junction
Box contains two Distribution Cable Harness plugs, one breaker plug and a terminal block for
the connection of a neutral current sensor and an auxiliary switch. Product number SDCJBA
is for general purpose OEM applications. Product number SDCJBB is designed for mounting
in Spectra? Series Panelboards. List Price
Description Product Number GO-135PM
Distribution Cable Junction Box SDCJBA3 纬轩机电155.00
Distribution Cable Junction Box SDCJBB 纬轩机电155.00
3Limited availability—obselete when inventory depleted.
Power Supply Plate
Voltage Conditioner Plate
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-13
to change without notice
Molded Case Circuit Breakers
Power Management System Accessories
Spectra? RMS Circuit Breakers with MicroVersaTrip? Plus and MicroVersaTrip? PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)
Distribution Cable Harness3
The Distribution Cable Harness is a modular connector used to carry electronic signals
and/or control power between Spectra? RMS Molded Case Circuit Breakers with
MicroVersaTrip? Plus or MicroVersaTrip? PM Trip Units and Distribution Cable accessories.
The harnesses come in three lengths. List Price
Description Harness Length Product Number GO-135PM
Distribution Cable Harness 11 inches SDCHA11 纬轩机电70.00
Distribution Cable Harness 30 inches SDCHA30 纬轩机电80.00
Distribution Cable Harness 60 inches SDCHA60 纬轩机电100.00
3Cannot be connected together. Use 30 inch Distribution Cable Extension (SDCEA30) to extend.
Distribution Cable Extension
The Distribution Cable Extension is used to provide modular expansion of the Distribution
Cable System. List Price
Description Harness Length Product Number GO-135PM
Distribution Cable Extension 30 inches SDCEA30 纬轩机电80.00
Distribution Cable Terminal Block
The Distribution Cable Terminal Block is a modular attachment primarily used to provide
an alternate means of input to Spectra? RMS Molded Case Circuit Breakers with
MicroVersaTrip? Plus or MicroVersaTrip? PM Trip Units. The Terminal Block plugs into the
breaker distribution cable receptacle allowing the direct connection of breaker signals
via screw terminals. This allows point-to-point wiring of breakers instead of using the
Distribution Cable System. List Price
Description Product Number GO-135PM
Distribution Cable Terminal Block SDCTBA11 纬轩机电110.00
Power Supply Assembly
The Power Supply Assembly is used to provide +24 Vdc Control Power to Spectra? RMS
Molded Case Circuit Breakers with MicroVersaTrip? Plus or MicroVersaTrip? PM trip systems
via the Distribution Cable System. The assembly requires a minimum input voltage of 85
Vac to operate properly (the maximum voltage rating is 240 Vac). Supplemental +24 Vdc
input terminals are provided for backup control power applications. The input must be
fused with 1/2 ampere class CC fuses (not included). Not suitable for 400 Hz. List Price
Description Voltage Rating Product Number GO-135PM
The Power Supply Assembly is rated 24 watts 85 - 240 Vac SPSAA 纬轩机电1000.00
(+24 Vdc @ 1.0 ampere) and has the maximum
capacity to power a Distribution Cable System
consisting of 20 breakers and has a maximum
system cable length of 40 feet.
Distribution Cable Extension
Distribution Cable Terminal Block
Power Supply Assembly
Required Accessories
Type Accessories
Standard –
Ground Fault Option with 3-phase, 4-wire Neutral Current Sensor and Terminal Block
MicroVersaTrip? Plus Trip Unit or 1-phase, 3-wire service or Neutral Current Sensor and Junction Box
Control Power Option Power Supply Plate or Voltage Module1 or Power Supply Assembly2
Power Supply Plate and Voltage Conditioner Plate or Voltage Module1
Standard or with Protective Relaying or Power Supply Assembly2 and Voltage Conditioner Assembly2
MicroVersaTrip? PM Trip Unit Junction Box, Cable Harness and Auxiliary Switch
Ground Fault Option with 3-phase, 4-wire Neutral Current Sensor
or 1-phase, 3-wire service
1For installation into GE Spectra? Series Switchboards only.
2Requires fuse protection and other components; refer to accessory detail for additional information.
Distribution Cable Harness
Components: Parts
1
1-14 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Molded Case Circuit Breakers
Power Management System Accessories
Spectra? RMS Circuit Breakers with MicroVersaTrip? Plus and MicroVersaTrip? PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)
Voltage Modules
The Voltage Module is used primarily as a Spectra? Series Switchboard component
to provide +24 Vdc Control Power to Spectra? RMS Molded Case Circuit Breakers with
MicroVersaTrip? Plus or MicroVersaTrip? PM Trip Units via the Distribution Cable System.
The Module also provides voltage sensing signals to Spectra? RMS Molded Case Circuit
Breakers with MicroVersaTrip? PM Trip Units on the same Distribution Cable System. The
Module contains both a Power Supply Plate and a Voltage Conditioner as integral components.
It also includes fuse protection for the AC source input terminals (the modules
pressure connectors which mate with the switchboard interior bus bars). A GE POWER
LEADER? Network (commnet) connection is provided as well as supplemental 24 Vdc
input terminals for backup control power applications. Seven versions are available. Not
suitable for 400 Hz.
List Price
Voltage Rating and Service Type Comments Product Number GO-135PM
120 Vac Wye system Phase to Neutral potential ADSVMA120Y 纬轩机电2350.00
208 Vac Wye system Phase to Phase potential ADSVMA208Y 纬轩机电2350.00
240 Vac Delta system Phase to Phase potential ADSVMA240D 纬轩机电2350.00
277 Vac Wye system Phase to Neutral potential ADSVMA277Y 纬轩机电2350.00
480 Vac Wye system Phase to Phase potential ADSVMA480Y 纬轩机电2350.00
480 Vac Delta system Phase to Phase potential ADSVMA480D 纬轩机电2350.00
600 Vac Delta system Phase to Phase potential ADSVMA600D 纬轩机电2350.00
Note: The Voltage Module has the maximum capacity to power a Distribution Cable System consisting of 20
breakers and has a maximum system cable length of 40 feet.
Voltage Module Exterior View Voltage Module Interior View
Voltage Conditioner Assembly
Voltage Conditioner Assembly
The Voltage Conditioner Assembly is used to provide voltage sensing signals to Spectra?
RMS Molded Case Circuit Breakers with MicroVersaTrip? PM Trip Units via the Distribution
Cable System. The Voltage Conditioner Assembly requires a control power source of +24
Vdc to operate properly (the Power Supply Assembly or Power Supply Plate can provide
this required input). The unit also requires 120 Vac voltage inputs from the secondary
of three 1-VA high accuracy potential transformers (not included). The primary side of
the potential transformers must be fused with three, 1/2 ampere class CC fuses (not
included). A GE POWER LEADER? network (commnet) connection is provided. Not suitable
for 400 Hz.
List Price
Description Voltage Rating Product Number GO-135PM
Requires 120 Vac voltage inputs from the 120 Vac SVCAA 纬轩机电680.00
secondary of three 1.0 VA high accuracy
potential transformers
Note: the Voltage Conditioner Assembly has the maximum capacity to power a Distribution Cable System
consisting of 20 breakers and has a maximum system cable length of 40 feet.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-15
to change without notice
Molded Case Circuit Breakers
Accessories–Other
Spectra? RMS Circuit Breakers with MicroVersaTrip? Plus and MicroVersaTrip? PM Trip Units
All Devices UL Listed for Factory or Field Installation Except Where Noted
Neutral Current Sensor
The neutral current sensor is used in conjunction with breakers that have a MicroVersaTrip?
Plus or MicroVersaTrip? PM Trip Unit with the optional ground fault function and the breaker
is connected to a grounded neutral service (3-phase, 4-wire or 1-phase, 3-wire). The neutral
current sensor provides an input signal to the breaker trip unit. Breakers connected to a
service without a neutral (3-phase, 3-wire) require no external connection or shorting of
the breaker cable connector for ground fault to function properly.
List Price
Breaker Type Sensor Rating (S) Product Number GO-135S
SG 150 TSRG201 纬轩机电532.00
SG 400 TSRG204 纬轩机电532.00
SG 600 TSRG206 纬轩机电532.00
SK 800 TSKG408 纬轩机电532.00
SK 1200 TSKG412 纬轩机电532.00
Voltage Current (mA) Product List Price
ac dc Inrush Cont Number GO-135S
120 125 500 6.0 SAST1 纬轩机电363.00
240 250 400 5.0 SAST2 纬轩机电363.00
— 12 1000 800 SAST51 纬轩机电363.00
24 24 300 10.0 SAST3 纬轩机电363.00
48 48 300 10.0 SAST4 纬轩机电363.00
1Not suitable for use with ground fault sensing and relaying equipment.
Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.
Auxiliary Switch
Auxiliary switches provide remote indication of whether the circuit breaker main
contacts are opened or closed via open or closed SPDT switch elements.
Switch Number of Auxiliary Switch List Price
Rating Switch Elements Product Number GO-135S
5A @240 Vac/ 1 form C SAUXPAB1 纬轩机电149.00
0.5A @ 125 Vdc 2 form C SAUXPAB2 纬轩机电295.00
Gold-Plated Contacts 1 form C SAUXGAB1 纬轩机电149.00
0.5A @ 30V 2 form C SAUXGAB2 纬轩机电295.00
One each 2 form C SAUXGPAB2 纬轩机电295.00
of above types
Shunt Trip
For remote tripping of breaker, use with momentary close contact. Not recommended for
use with latching relay contact since electronics in shunt trip will pulse power to the coil
if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2
seconds at rated control voltage. (A short-circuit trip would be instantaneous.)
If maintained (latching relay) contact must be used and delayed shunt tripping is not
acceptable, use small bell alarm in series with control power for SE150 and SF250 frames
and auxiliary switch for SG600 and SK1200 breakers.
These devices are suitable for use with ground fault sensing and relaying equipment.
Maximum VA is 75. AC devices are UL listed for 50-60 Hz.
Red
White
Brown/white
Black
Black
All accessory contacts shown
with the circuit breaker in
tripped position.
All accessory contacts shown
with the circuit breaker in
tripped position.
Auxiliary Switch
Shunt Trip
Internal Accessories, Spectra? RMS Circuit Breakers
Components: Parts
1
1-16 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Actuator
All Spectra? circuit breakers are supplied with an actuator installed in the left-side pouch.
The actuator is removed when installing either a shunt trip or undervoltage release.
List Price
Description Product Number GO-148C
Replacement Actuator SACTUATOR 纬轩机电250.00
Voltage Peak Current Product List Price
ac dc (mA) Number GO-135S
120 125 200 SAUV1 纬轩机电363.00
240 250 200 SAUV2 纬轩机电363.00
24 24 100 SAUV3 纬轩机电363.00
48 48 100 SAUV4 纬轩机电363.00
120 125 SPUVTD 纬轩机电430.001
1GO-245B.
Switch Number of Product List Price
Rating Switch Elements Number GO-135S
5A @ 240 Vac/ 1 form C SABAP1 纬轩机电154.00 0.5A @ 125 Vdc
Gold-Plated Contacts 1 form C SABAG1 纬轩机电154.00 0.5A @30V
Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.
Bell Alarm Switch
The bell alarm switch provides remote indication of whether the circuit breaker has been
tripped via open or closed SPDT switch elements, but remains unchanged during "On/Off"
circuit breaker operation and during operation by the "Push-to-Trip" button.
Undervoltage Release
Undervoltage Release
The undervoltage release provides automatic circuit breaker tripping when there is a
power loss or major dip (to 35%-70% of rated voltage) in accessory control voltage. AC
devices are UL listed for 50-60 Hz. Product number SAUV1 may be used with time delay
unit SPUVTD (List Price 纬轩机电430.00, GO-245B) (delay 0.1 to 1.0 seconds), 120 Vac input,
125 Vdc output.
Bell Alarm Switch
Purple
Yellow
Brown
Blue
Blue
All accessory contacts shown
with the circuit breaker in
tripped position.
All accessory contacts shown
with the circuit breaker in
tripped position.
Molded Case Circuit Breakers
Internal Accessories
Spectra? RMS Circuit Breakers
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-17
to change without notice
Contacts – Auxiliary and Bell Alarm (Rated 5A @240VAC, 0.5A @125VDC)
Normally Open Normally Closed
List Price List Price
Accessory Product No. GO-135H Product No. GO-135H
Aux. Switch Right Mounted FAS10RW 纬轩机电149.00 FAS01RW 纬轩机电149.00
Aux. Switch Left Mounted FAS10LW 纬轩机电149.00 FAS01LW 纬轩机电149.0
Bell Alarm Mechanism FABAM10W 纬轩机电154.00 FABAM01W 纬轩机电154.00
Releases – Shunt Trip and Undervoltage
Shunt Trip Undervoltage Release
Rating (Inrush List Price Rating (Inrush List Price
Voltage Power Consumption) Product No. GO-135H Power Consumption) Product No. GO-135H
12 VDC 200 mA / 2.4W FASHTBW 纬轩机电363.00 — ——
24 VAC/DC 100 mA / 3.6W FASHTDW 纬轩机电363.00 50 mA / 1.2W FAUVRDW 纬轩机电363.00
48 VAC/DC 60 mA / 2.88W FASHTFW 纬轩机电363.00 20 mA / 0.96W FAUVRFW 纬轩机电363.00
120 VAC 40 mA / 4.8W FASHTKW 纬轩机电363.00 — ——
110/130 VAC/DC 40 mA / 4.8W FASHTJW 纬轩机电363.00 15 mA / 1.8W FAUVRJW 纬轩机电363.00
220/240 VAC, 250 VDC 20 mA / 4.6W FASHTNW 纬轩机电363.00 15 mA / 3.45W FAUVRNW 纬轩机电363.00
277 VAC 11 mA / 3.0W FASHT7W 纬轩机电363.00 15 mA / 4.0W FAUVR7W 纬轩机电363.00
400/480 VAC 20 mA / 8.4W FASHTUW 纬轩机电363.00 15 mA / 6.3W FAUVRUW 纬轩机电363.00
Auxiliary Switch/Bell Alarm Mechanism
Shunt Trip/Undervoltage Release
Molded Case Circuit Breakers
Accessories
Record Plus? FC 100
Lugs and Lug Kits
Single Lug List Price Lug Kit List Price
Amp Range Wire Range Strip Length Product No. GO-135H Product No. (Set of 3) GO-135H
15-20A 14-10 Cu/Al .40-.50” FCAL12 纬轩机电3.25 FCALK12 纬轩机电9.00
25-60A 10-4 Cu/Al .40-.50” FCAL13 纬轩机电3.25 FCALK13 纬轩机电9.00
70-100A 4-1/0 Cu/Al .40-.50” FCAL14 纬轩机电3.25 FCALK14 纬轩机电9.00
External Accessories
Components: Parts
1
1-18 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Molded Case Circuit Breakers
Accessories
Record Plus? FE 250
FE Rating Plugs List Price
Trip Curve CT Rating Rated Current Product No. GO-135H
25A 20 A FERP3B0020 纬轩机电106.00
25 A FERP3B0025 纬轩机电106.00
30 A FERP3D0030 纬轩机电106.00
40 A FERP3D0040 纬轩机电106.00 60A 50 A FERP3D0050 纬轩机电106.00
60 A FERP3D0060 纬轩机电106.00
70 A FERP3G0070 纬轩机电106.00
80 A FERP3G0080 纬轩机电106.00
DES-200 90 A FERP3G0090 纬轩机电106.00 125A 100 A FERP3G0100 纬轩机电106.00
110 A FERP3G0110 纬轩机电106.00
125 A FERP3G0125 纬轩机电106.00
150A 150 A FERP3H0150 纬轩机电106.00
175 A FERP3K0150 纬轩机电106.00
200 A FERP3K0200 纬轩机电106.00 250A 225 A FERP3K0225 纬轩机电106.00
250 A FERP3K0250 纬轩机电106.00
Bell Alarm
Contact List Price
Configuration Contact Rating Wire leads Product No. GO-135H
1 NO (Form A) 5A @ 277 VAC, #16 AWG FABAM10W 纬轩机电154.00
0.3A @ 125 VDC
1 NC (Form B) 5A @ 277 VAC, #16 AWG FABAM01W 纬轩机电154.00
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Internal and External Accessories
Neutral Grounds and Sensors
Neutral Current Sensors
For grounded neutral system ground fault applications
List Price
Breaker Type Ampere Rating Product Number GO-135S
150 TSRG201 纬轩机电532.00
200 TSRG202 纬轩机电532.00
300 TSRG203 纬轩机电532.00 J 400 TSRG204 纬轩机电532.00
500 TSRG205 纬轩机电532.00
600 TSRG206 纬轩机电532.00
800 TSKG408 纬轩机电532.00
K 1000 TSKG410 纬轩机电532.00
1200 TSKG412 纬轩机电532.00 Neutral Current Sensor
Breaker Frames & Ratings Plugs
Insulated Case Circuit Breakers
Circuit Breakers History/Timeline
GE Insulated Case Circuit Breakers History/Timeline
1965 GE pioneered the design of insulated case circuit breakers when it introduced the original
Power Break? circuit breaker.
1995 GE introduced Power Break? II insulated case circuit breakers, the vanguard of a new age in reliable, flexible
and easy-to-use circuit protection.
Evolution of the GE Trip Unit
1965 Dual Magnetic Trip
1975 VersaTrip Solid State Trip
1979 VersaTrip Mod 2 Solid State Trip
1979 Magnetrip-Dual Mag
1979 SelecTrip
1982 MicroVersaTrip?
1988 MicroVersaTrip? RMS 9
1989 MicroVersaTrip? RMS 9 / Epic
1994 MicroVersaTrip? Plus/PM
1995 Enhanced MicroVersaTrip? Plus/PM
1996 Power Break? II MicroVersaTrip? Plus/PM
1997 Power Break? II Powerplus
2009 EntelliGuard? TU
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-19
to change without notice
This catalog contains replacement parts, retrofits, accessories,
and older generation products. For current generation products,
please see the GE BuyLog? or Control Catalog.
Components: Parts
1
1-20 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Enhanced MicroVersaTrip?, Rating Plug Selection
Power Break? II Rating Plug Selection
Enhanced
MicroVersaTrip? Plus
Power+ Trip and Enhanced
Power+ Trip Unit Ground MicroVersaTrip? PM
Unit Standard Fault Rating Trip Unit
Frame Sensor Current Rating Plugs Plugs Rating Plugs
Size Rating Rating List Price 纬轩机电89.00 List Price 纬轩机电747.00 List Price 纬轩机电89.00
(Amperes) (Amperes) (Amperes) GO-245A GO-245A GO-245A
100 TR2C100 TR2C100GF TR2B100
200 150 TR2C150 TR2C150GF TR2B150
200 TR2C200 TR2C200GF TR2B200
150 – – TR4B150
800 200 TR4C200 TR4C200GF TR4B200
225 TR4C225 TR4C225GF TR4B225 400 250 TR4C250 TR4C250GF TR4B250
300 TR4C300 TR4C300GF TR4B300
400 TR4C400 TR4C400GF TR4B400
300 – – TR8B300
400 TR8C400 TR8C400GF TR8B400
450 TR8C450 TR8C450GF TR8B450
800-1600 800 500 TR8C500 TR8C500GF TR8B500
600 TR8C600 TR8C600GF TR8B600
700 TR8C700 TR8C700GF TR8B700
800 TR8C800 TR8C800GF TR8B800
400 – – TR10B400
1000 600 TR10C600 TR10C600GF TR10B600
800 TR10C800 TR10C800GF TR10B800
1000 TR10C1000 TR10C1000GF TR10B1000
1600 600 – – TR16B600
800 TR16C800 TR16C800GF TR16B800
1600 1000 TR16C1000 TR16C1000GF TR16B1000
1100 TR16C1100 TR16C1100GF TR16B1100
1200 TR16C1200 TR16C1200GF TR16B1200
1600 TR16C1600 TR16C1600GF TR16B1600
750 – – TR20B750
800 – – TR20B800
1000 TR20C1000 TR20C1000GF TR20B1000
2000 2000 1200 TR20C1200 TR20C1200GF TR20B1200
1500 TR20C1500 TR20C1500GF TR20B1500
1600 TR20C1600 TR20C1600GF TR20B1600
2000 TR20C2000 TR20C2000GF TR20B2000
400 – – TR10B400
600 TR10C600 TR10C600GF TR10B600 1000 800 TR10C800 TR10C800GF TR10B800
1000 TR10C1000 TR10C1000GF TR10B1000
750 – – TR20B750
800 – – TR20B800
1000 TR20C1000 TR20C1000GF TR20B1000 2500 2000 1200 TR20C1200 TR20C1200GF TR20B1200
1500 TR20C1500 TR20C1500GF TR20B1500
1600 TR20C1600 TR20C1600GF TR20B1600
2000 TR20C2000 TR20C2000GF TR20B2000
1600 TR25C1600 TR25C1600GF TR25B1600
2500 2000 TR25C2000 TR25C2000GF TR25B2000
2500 TR25C2500 TR25C2500GF TR25B2500
1200 – – TR30B1200
1600 – – TR30B1600
3000 3000 2000 TR30C2000 TR30C2000GF TR30B2000
2500 TR30C2500 TR30C2500GF TR30B2500
3000 TR30C3000 TR30C3000GF TR30B3000
1600 TR40C1600 TR40C1600GF TR40B1600
2000 TR40C2000 TR40C2000GF TR40B2000
4000 4000 2500 TR40C2500 TR40C2500GF TR40B2500
3000 TR40C3000 TR40C3000GF TR40B3000
3600 TR40C3600 TR40C3600GF TR40B3600
4000 TR40C4000 TR40C4000GF TR40B4000
MicroVersaTrip? and MicroVersaTrip? PM Rating Plug
Trip Indicator Product List Price
L/ST/1 Ground Fault Number GO-245A
– – TARGET00 纬轩机电60.00
? – TARGET01 纬轩机电140.00
? ? TARGET02 纬轩机电160.00
Power+ Target Module
Power+ trip units are designed to accept an optional field-installable
target module. The target module indicates long-time pickup, battery
status, trip unit health status, and whether a breaker trip was
caused by an overload, a short circuit or a ground fault. Target
modules are available with or without ground fault indication.
Power+ Trip Target Module
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-21
to change without notice
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
120 – SPE120R 纬轩机电1671.00 SPE120 纬轩机电1838.00
240 – SPE240R 纬轩机电1869.00 SPE240 纬轩机电2056.00
– 24 SPE024R 纬轩机电1869.00 SPE024 纬轩机电2056.00
– 48 SPE048R 纬轩机电1869.00 SPE048 纬轩机电2056.00
– 72 SPE072R 纬轩机电1869.00 SPE072 纬轩机电2056.00
– 125 SPE125R 纬轩机电1869.00 SPE125 纬轩机电2056.00
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
120 – SPRCS120R 纬轩机电286.00 SPRCS120 纬轩机电315.00
240 – SPRCS240R 纬轩机电286.00 SPRCS240 纬轩机电315.00
– 24 SPRCS024R 纬轩机电286.00 SPRCS024 纬轩机电315.00
– 48 SPRCS048R 纬轩机电286.00 SPRCS048 纬轩机电315.00
– 72 SPRCS072R 纬轩机电286.00 SPRCS072 纬轩机电315.00
– 125 SPRCS125R 纬轩机电286.00 SPRCS125 纬轩机电315.00
Electrical Operator
Remote Close Solenoid
This accessory provides an electrically operated solenoid which, when energized, closes
the breaker. It is suitable for control interlock schemes in which manual closing capability
would not be convenient or desirable. The breaker is provided with a manual close
button, which can be replaced by the Hidden "ON" Button accessory and/or sealed using
the Limited Access Pushbutton Cover accessory. The remote close accessory is continuously
rated and has an anti-pump feature, which prevents a motor operated breaker
from repeatedly closing into a fault. Closing control voltage must be removed and re-applied
for each breaker closure.
Remote Close Solenoid
Accessories—Stationary and Draw-out Breakers
The complete line of Power Break? II breaker accessories may be either factory or field
installed to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm with
mechanical lockout, and the undervoltage release modules are drop-in from the front of
the breaker, interchangeable across all frames, and require no field internal wiring or
breaker disassembly. Auxiliary switch modules are available in groups of 4, 8 or 12,
NO/NC single-pole, double-throw (SPDT) switches. Their installation simply involves
removal of breaker cover, installation of the switch module, routing of wiring and installation
of the pre-wired terminal block and re-installation of the cover. Auxiliary switches
are also interchangeable across all Power Break? II breaker frames.
Electrical Operator
The electrical operator mounts inside the front cover of the manually operated breaker.
This accessory can be added to any Power Break? II breaker in the factory or the field
to provide electrical spring charging and charge indication. For remote closing, the
remote close solenoid must be priced and ordered separately. All breakers are
prewired to dedicated secondary terminals for easy field installation. When electrical
operation is used, either a shunt trip or an undervoltage release must be ordered and
priced separately.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-22 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Shunt Trip
The shunt trip accessory is an electronic module, which provides remote control capability
to open the circuit breaker. When activated, the shunt trip module sends a signal to
the trip unit to open the breaker. This allows the trip unit to record, display, distinguish
and communicate (in MicroVersaTrip? PM trip units) that the opening event was initiated
by the shunt trip device. The shunt trip is continuously rated and requires no cut-off
switch. When energized, the shunt trip supplies +24Vdc power to the trip unit to power
the display.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
– 12 SPST012R 纬轩机电301.00 SPST012 纬轩机电328.00
24 24 SPST024R 纬轩机电301.00 SPST024 纬轩机电328.00
48 48 SPST048R 纬轩机电301.00 SPST048 纬轩机电328.00
120 125 SPST120R 纬轩机电301.00 SPST120 纬轩机电328.00
208 – SPST208R 纬轩机电301.00 SPST208 纬轩机电328.00
240 250 SPST240R 纬轩机电301.00 SPST240 纬轩机电328.00
480 – SPST480R1 纬轩机电301.00 SPST4801 纬轩机电328.00
600 – SPST600R1 纬轩机电301.00 SPST6001 纬轩机电328.00
1Kit contains externally mounted transformer.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
12 SPSTL012R 纬轩机电401.00 SPSTL012 纬轩机电428.00
24 24 SPSTL024R 纬轩机电401.00 SPSTL024 纬轩机电428.00
48 48 SPSTL048R 纬轩机电401.00 SPSTL048 纬轩机电428.00
120 125 SPSTL120R 纬轩机电401.00 SPSTL120 纬轩机电428.00
208 – SPSTL208R 纬轩机电401.00 SPSTL208 纬轩机电428.00
240 250 SPSTL240R 纬轩机电401.00 SPSTL240 纬轩机电428.00
480 – SPSTL480R1 纬轩机电401.00 SPSTL480 纬轩机电428.00
600 – SPSTL600R1 纬轩机电401.00 SPSTL600 纬轩机电428.00
1Kit contains externally mounted transformer.
Shunt Trip Module
Shunt Trip with Lockout Module
The shunt trip with lockout is identical to the regular shunt trip, but when energized, it
will also prevent closure of an "open" breaker by mechanically blocking both manual and
electrical closing. When energized, the closing springs will not discharge, the movable
contacts will not move; the contacts are "kiss free."
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-23
to change without notice
Undervoltage Release Module
The undervoltage release is an electronic module used to open the circuit breaker when
the monitored voltage drops below 35-60% of its rated value. The undervoltage release
"resets" when the monitored voltage is re-established allowing the circuit breaker to reclose
(the sealing voltage of the UVR is 60-85% of its rated voltage).
An undervoltage release trip operation is produced by the MicroVersaTrip? Plus unit in
response to a signal from the undervoltage release module. This allows the trip unit to
record, display, distinguish and communicate (in MicroVersaTrip? PM trip units) that the
breaker opening event was due to undervoltage release. Operation of the undervoltage
release module will prevent breaker contact closure, i.e. "kiss-free" operation. When
energized, the undervoltage release supplies +24 Vdc power to the trip unit to power
the display.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
24 – SPUV024ACR 纬轩机电301.00 SPUV024AC 纬轩机电328.00
48 – SPUV048ACR 纬轩机电301.00 SPUV048AC 纬轩机电328.00
120 – SPUV120ACR 纬轩机电301.00 SPUV120AC 纬轩机电328.00
208 – SPUV208ACR 纬轩机电301.00 SPUV208AC 纬轩机电328.00
240 – SPUV240ACR 纬轩机电301.00 SPUV240AC 纬轩机电328.00
480 – SPUV480ACR1 纬轩机电301.00 SPUV480AC1 纬轩机电328.00
600 – SPUV600ACR1 纬轩机电301.00 SPUV600AC1 纬轩机电328.00
– 12 SPUV012DCR 纬轩机电301.00 SPUV012DC 纬轩机电328.00
– 24 SPUV024DCR 纬轩机电301.00 SPUV024DC 纬轩机电328.00
– 48 SPUV048DCR 纬轩机电301.00 SPUV048DC 纬轩机电328.00
– 125 SPUV125DCR 纬轩机电301.00 SPUV125DC 纬轩机电328.00
– 250 SPUV250DCR 纬轩机电301.00 SPUV250DC 纬轩机电328.00
1Kit contains externally mounted transformer.
Undervoltage Release Module
Bell Alarm (Alarm Only)
The bell alarm module is used to signal breaker "tripped" status to other accessories
(e.g., external alarm devices, indicating lights, relays, or logic circuits) for remote indication
and interlocking functions. The bell alarm response is configurable by means of
rear-mounted DIP switches on the trip unit. The bell alarm can be made to operate in
response to an overcurrent (including ground fault) or protective relay trip and/or a
shunt trip operation, and/or operation of the undervoltage release module. It is not
actuated as a result of normal breaker "ON/OFF" operation.
This module provides a visual, mechanical pop-out target, which protrudes through the
face of the circuit breaker door when it operates. The bell alarm may be reset manually
by depressing the mechanical target, or automatically by closing the breaker.
The bell alarm is provided with one SPDT switch with control power duty contacts as
shown in the auxiliary switch accessories.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
240 125-250 SPBAA240R 纬轩机电124.00 SPBAA240 纬轩机电135.00
600 125-250 SPBAA600R1 纬轩机电124.00 SPBAA6002 纬轩机电135.00
2600 Vac module not UL Listed.
Bell (Alarm Only)
List Price
Description Product Number GO-245B
Time Delay Module
(0.1 to 1.0 second delay) SPUVTD 纬轩机电430.00
Time Delay Module for UVR
The time delay module prevents nuisance tripping due to momentary loss of voltage.
The module has 120 Vac input and 125 Vdc output and must be used with the 125 Vdc UVR.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-24 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Bell Alarm With Lockout
The bell alarm with lockout module combines both the bell alarm and a manual lockout
function. The bell alarm switch operates identically to the standard bell alarm module,
except that the mechanical pop-out target must be manually reset before the breaker
can be closed.
Operation of the bell alarm with lockout module can be independently set by means
of setting the DIP switches at the rear of the trip unit. Current rating of the single SPDT
switch is identical to the auxiliary switch accessories.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
240 125-250 SPBAL240R 纬轩机电124.00 SPBAL240 纬轩机电135.00
600 125-250 SPBAL600R1 纬轩机电124.00 SPBAL6001 纬轩机电135.00
1600 Vac module not UL Listed. Bell Alarm with Mechanical Reset Lockout
Auxiliary Switch
An auxiliary switch signals the circuit breaker’s primary contact position (i.e., OPEN or
CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables
the user to provide remote indication, interlocking or control operations as a function of
breaker primary contact position. The auxiliary switch operation is independent of the
method by which the breaker is opened or closed. The auxiliary switch does not distinguish
between a "tripped" or "open" condition. The auxiliary switch contacts follow the
main breaker contacts on opening and precede them on closing.
Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control
power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module
comes pre-wired to its own terminal board, which mounts with one screw to the left of
the breaker. A special accessory, available for draw out breakers, comes pre-wired to the
breaker secondary disconnect. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125
Vdc and 1/4A at 250 Vdc.
Auxiliary Switches for Stationary Breakers
No. of SPDT
Ratings Ratings Switch Elements Field Installable List Price Factory Installed List Price
Vac Vdc (Contacts) Product Number GO-245B Product Number GO-245B
240 125-250 4 SPAS240AB4R 纬轩机电268.00 SPAS240AB4 纬轩机电293.00
240 125-250 8 SPAS240AB8R 纬轩机电564.00 SPAS240AB8 纬轩机电616.00
240 125-250 12 SPAS240AB12R 纬轩机电651.00 SPAS240AB12 纬轩机电710.00
600 125-250 4 SPAS600AB4R1 纬轩机电268.00 SPAS600AB41 纬轩机电293.00
600 125-250 8 SPAS600AB8R1 纬轩机电564.00 SPAS600AB81 纬轩机电616.00
1600 Vac module not UL Listed.
Auxiliary Switch with
Pre-wired Secondary Terminals
for Stationary Breaker
Auxiliary Switch with
Pre-wired Secondary Terminals
for Draw-out Breaker
Auxiliary Switches for Draw-out Breakers
No. of SPDT
Ratings Ratings Switch Elements Field Installable List Price Factory Installed List Price
Vac Vdc (Contacts) Product Number GO-245B Product Number GO-245B
240 125-250 4 SPAS240AB4DR 纬轩机电551.00 SPAS240AB4D 纬轩机电576.00
240 125-250 8 SPAS240AB8DR 纬轩机电847.00 SPAS240AB8D 纬轩机电899.00
240 125-250 12 SPAS240AB12DR 纬轩机电934.00 SPAS240AB12D 纬轩机电993.00
600 125-250 4 SPAS600AB4DR1 纬轩机电551.00 SPAS600AB4D1 纬轩机电576.00
600 125-250 8 SPAS600AB8DR1 纬轩机电847.00 SPAS600AB8D1 纬轩机电899.00
1600 Vac module not UL Listed.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-25
to change without notice
Mechanical Operations Counter
The mechanical operations counter is mounted behind the front cover of the breaker. It
is viewable through a rectangular knockout window opening in the breaker cover. It is a
five-digit, non-resettable counter, which is actuated each time the breaker is opened by
any means.
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPCOUNTERR 纬轩机电100.00 SPCOUNTER 纬轩机电125.00
Hidden "ON" Button
The hidden "ON" button is assembled to the mechanism behind an unlabeled, false
pushbutton. Manual closing of the breaker can only be performed by means of a small
diameter rod. This accessory is used to limit access to the manual "ON" control to
authorized personnel.
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPPBNONR 纬轩机电64.00 SPPBNON 纬轩机电64.00
Maintenance/Repair Parts
Description Product Number List Price GO Schedule
Top Cover and Rating Labels SPBII-REPLACE_COVER1 纬轩机电600.00 148C
Replacement MVT Door 10054335P1 纬轩机电20.00 148G
Replacement Powerplus Door 10054335P2 纬轩机电16.00 148G
Stop Block Kit w/Installation Tool SPBUMPERKIT 纬轩机电175.00 148C
Stop Block Kit (no tools) SPBUMPNTKIT 纬轩机电90.00 148C
1Special handling and order entry required to preserve UL Listing of breaker.
Contact Post Sale Service for additional details of special process.
Limited Access Pushbutton Cover
This accessory limits access to "ON/OFF" control of a breaker to authorized personnel.
The pushbutton cover accessory consists of transparent hinged covers that can be individually
sealed to the limited access assembly. Both the "ON" and "OFF" buttons can be
pilot drilled to allow use of a 1/8" rod to operate either one or both pushbuttons.
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPPBCOVERR 纬轩机电80.00 SPPBCOVER 纬轩机电90.00
Mechanical Operations Counter
Breaker with limited access pushbutton
cover assembly installed
Activating the breaker closing
mechanism through the hole in the
Hidden “ON” Button
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-26 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Key Interlock Provisions
The key interlock provision enables the user to mount a one- to four-cylinder, narrowfaced,
Kirk-type FN or Superior customer-supplied lock on the face of the breaker. This
accessory provides mounting for key interlocks that are furnished by the customer. The
key interlock provision works in conjunction with the padlock provision. The key interlock
extends a lever through the padlock hasp when the key is turned to the key removal or
bolt extended position. Additionally, the accessory provides a hasp for mounting three
padlocks with 1/4" to 3/8" diameter shanks.
Padlock Provisions (Standard)
Padlocking provisions are standard on all Power Break? II circuit breakers. When the
breaker is in the open position, and the padlock hasp is raised at least 1/4", the breaker
cannot be closed mechanically or electrically. The hasp accepts up to three padlocks
with 1/4" to 3/8" diameter shanks.
Walking Beam Interlocks—Stationary Breakers Only
Walking beam interlocks are mechanical devices used to prevent two adjacent circuit
breakers from both being in the "ON" or closed position at the same time. However, both
breakers can be in the "OFF" or open position.
Door Interlock
The door interlock provides interlocking of the circuit breaker compartment’s hinged
door so that the breaker must be in the "OFF" position before the door can be opened.
The door interlock is defeatable with a small tool to allow authorized access.
Circuit Breaker List Price
Envelope Size (Amperes) Product Number GO-245B
800, 1600 and 2000 SPWB20 纬轩机电1228.00
3000 SPWB30 纬轩机电1228.00
4000 SPWB40 纬轩机电1228.00
Product Numbers, Key Interlock Provisions
Circuit Breaker Number of Field Installed List Price Factory Installed List Price
Envelope Size (Amps) Key Locks Product Number GO-245B Product Number GO-245B
All 1 to 4 SPK4R 纬轩机电355.00 SPK4 纬轩机电426.00
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPDILR 纬轩机电173.00 SPDIL 纬轩机电208.00
Key Interlock Kit (lock not included)
Door Interlock
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
展开